• Title/Summary/Keyword: dental filling materials

Search Result 127, Processing Time 0.028 seconds

An Experimental Study on Microleakage in Light-activated Temporary Filling Materials (광중합형 임시충전재의 미세누출에 관한 실험연구)

  • Hwang, Su-Hyun;Yu, Ji-Su;Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.333-337
    • /
    • 2011
  • The purpose of this experiment was to examine possibility of microleakage by water, temperature change, and bite force inside the mouth during the period of using light-activated temporary filling materials. 2 kinds of light-activated temporary filling materials were used in order to measure weight and compressive strength and to evaluate microleakage between filling material and cavity wall according to frequency of thermal circulation. First, Light-activated temporary filling material was increased the weight, which was measured according to the period of using. As for the result of comparing between products, the weight of Quicks was indicated to be higher. Second, Compressive strength of Spacer had significant difference depending on period of using. However, significant difference wasn't shown in the compressive strength of Quicks. In Spacer that showed significant difference, the compressive strength increased greatly in the difference of 3 days. Third. As for micro-leakage according to frequency of thermal circulation, the microleakage was indicated to be the highest in the group that carried out 7,000 times. The group with operation of 1,000 times and the group with operation of 3,000 times were indicated the statistically lower micro-leakage than the group with operation of 7,000 times. This study brought about a rise in micro-leakage depending on the passage in the period of using. However, it is obvious fact that micro-leakage increases according to the passage of time after restoration.

Micro-computed tomographic evaluation of the flow and filling ability of endodontic materials using different test models

  • Torres, Fernanda Ferrari Esteves;Guerreiro-Tanomaru, Juliane Maria;Chavez-Andrade, Gisselle Moraima;Pinto, Jader Camilo;Berbert, Fabio Luiz Camargo Villela;Tanomaru-Filho, Mario
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.11.1-11.9
    • /
    • 2020
  • Objectives: This study compared the flow and filling of several retrograde filling materials using new different test models. Materials and Methods: Glass plates were manufactured with a central cavity and 4 grooves in the horizontal and vertical directions. Grooves with the dimensions used in the previous study (1 × 1 × 2 mm; length, width, and height respectively) were compared with grooves measuring 1 × 1 × 1 and 1 × 2 × 1 mm. Biodentine, intermediate restorative material (IRM), and mineral trioxide aggregate (MTA) were evaluated. Each material was placed in the central cavity, and then another glass plate and a metal weight were placed over the cement. The glass plate/material set was scanned using micro-computed tomography. Flow was calculated by linear measurements in the grooves. Central filling was calculated in the central cavity (㎣) and lateral filling was measured up to 2 mm from the central cavity. Results: Biodentine presented the least flow and better filling than IRM when evaluated in the 1 × 1 × 2 model. In a comparison of the test models, MTA had the most flow in the 1 × 1 × 2 model. All materials had lower lateral filling when the 1 × 1 × 2 model was used. Conclusions: Flow and filling were affected by the size of the test models. Higher grooves and materials with greater flow resulted in lower filling capacity. The test model measuring 1 × 1 × 2 mm showed a better ability to differentiate among the materials.

Essential of Endodontic microsurgery with the use of a Surgical Operating Microscope (외과적 근관치료의 핵심 - 치근단 미세누출 폐쇄술)

  • Kim, Sunil
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.556-564
    • /
    • 2017
  • Endodontic surgery is a procedure to treat apical periodontitis or abscess in cases that did not heal after nonsurgical treatment or retreatment. This might include situations with persistent intracanal infection after root canal treatment. Other reasons might be found in extraradicular infection, such as bacterial biofilm on the apical root surface or bacteria within the lesion. For many years, the treatment standard was the traditional approach with surgical burs and amalgam for root-end filling. Endodontic microsurgery is the most recent step in the evolution of endodontic surgery, applying not only ultrasonic tip and biocompatible filling materials but also incorporating high-power magnification and illumination. Although many studies have been published that advocate the use of modern technique, the traditional techniques are still widely used in the surgery community. The purpose of this study was to demonstrate the endodontic microsurgery procedure including the root-end preparation and filling with the use of a surgical operating microscope.

  • PDF

Current status of the types of dental filling and preventive materials among children in mixed dentition (혼합치열기 어린이의 치아우식 예방 및 충전 재료 현황에 관한 조사)

  • Oh, Ae-Young;Choi, Youn-Hee;Jin, Hye-Jung;Park, Ji-Hye;Kim, Young-Suk;Kwon, Ho-Jang;Song, Keun-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1483-1491
    • /
    • 2010
  • The purpose of this study was to examine current status of the types of dental filling materials and preventive materials among Korean children in mixed dentition. Seven elementary schools were randomly selected from four metropolitan regions in South Korea. The total of 711 children aged 9-10 years old were examined with their parents’ informed consents. Oral examination was conducted by one trained dentist. The mean number of dfs was $7.9{\pm}8.0$ ($ds=1.3{\pm}2.5,\;fs=6.6{\pm}7.6$) and DMFS was $1.4{\pm}2.2$ ($DS=0.2{\pm}0.8,\;FS=1.1{\pm}2.1$). The average of filled surfaces using amalgam, composites, sealants, and others were $2.8{\pm}3.9,\;1.6{\pm}2.8,\;2.9{\pm}3.2$, and $4.5{\pm}7.0$, respectively. The use of dental filling material according to region, the amalgam was the highest in Daegu and the resin was the highest in Pusan. In permanent teeth, about 70% of total filling surfaces had sealant and about 20% was resin fillings, and the proportion of amalgam filling surfaces was less than 10%.

CAE Analysis of Powder Injection Molding Process for Dental Scaler Mold (치과용 스케일러 금형의 분말사출성형 CAE 해석설계)

  • Ko Y. B.;Park H. P.;Chung S. T.;Rhee B. O.;Hwang C. J.
    • Transactions of Materials Processing
    • /
    • v.14 no.6 s.78
    • /
    • pp.570-576
    • /
    • 2005
  • Powder Injection Molding(PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry With this regards, design technology of dental scaler tip PIM mold, which has complex shape and small core pin (diameter=0.6mm), with the help of computer-aided analysis of powder injection molding process was developed. Computer-aided analysis for dental scaler tip mold was implemented by finite element method with non-Newtonian fluid, modified Cross model viscosity, PvT data of powder/binder mixture. Compter-aided analysis results, such as filling pattern, weldline formation, air vent position prediction were compared with experimental result, and eventually have been shown good agreement. The core pin (diameter=0.6mm) deflection analysis of dental scaler tip PIM mold during PIM filling process was also investigated before mold fabrication.

The Relationship between Dental Amalgam Fillings and Urinary Mercury Concentration among Elementary School Children in a Metropolitan Area (대도시지역 일부 초등학생의 치과용 아말감 충전치아와 요중 수은농도의 관련성)

  • Jung, Yun-Sook;Sakong, Joon;An, Seo-Young;Lee, Young-Eun;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.3
    • /
    • pp.253-258
    • /
    • 2012
  • Dental amalgam is an alloy composed of a mixture of approximately equal parts of elemental liquid mercury and an alloy powder. Amalgam has been the most popular and effective restorative material used in dentistry. Despite the long history and popularity of dental amalgam as a restorative material, there have been periodic concerns regarding the potential adverse health effects arising from exposure to mercury in amalgam. Since children are more at risk for mercury toxicity, we aimed to assess the association between dental amalgam filling and urinary mercury concentration in children. 581 of elementary school children in grades 1st4th were conveniently recruited from two schools located in Daegu city, Korea. To obtain dental caries experience states, oral examination were conducted using the full term for DFS index, number of amalgam filling surfaces and the type of filling materials. A questionnaire was used to collect information about general characteristics and the frequencies of tooth brushing, gum chewing and fish/seafood consumption. The statistical analysis was done using the SPSS 18.0 program. The mean urinary mercury concentration in children having more surfaces was highest. As a results Urinary mercury concentration of children who have 79 teeth of amalgam filling and more than 10 is higher than without amalgam filling. The number of amalgam filling surface is closely related with urinary mercury concentration.

Comparative Study on the Color Stability of Temporary Prosthetic Materials for Dental CAD-CAM (치과 CAD-CAM용 임시 수복재의 색 안정성 비교 연구)

  • Lee, Hye-Eun;Kim, Won-Soo;Kim, Jung-suk;Lee, Ju-hee;Won, Seuck-Jae
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • Purpose: This study was conducted to examine the color stability of temporary prosthetic materials for dental CAD-CAM. Method: 2 kinds of existing acrylic resin temporary filling materials and 2 kinds of polymer prosthetic materials for dental CAD-CAM were used for testing, and five specimens respectively were absorbed in soy sauce, red pepper paste, and coffee. A Chroma Meter was used as analysis equipment. The color change of the specimens was observed to calculate ${\Delta}E$ value throughout 2 days, 3 days, 4 days, and 5 days and this was analyzed and the following result was obtained. Results: Snap's ${\Delta}E$ value was bigger than Vipi block(p<0.05). Red pepper paste had the largest impact on the color change of resin(${\Delta}E$), followed by soy sauce and coffee(p<0.000). With the passage of time, ${\Delta}E$ value was inversely(-) related and decreased somewhat(p<0.000).