• Title/Summary/Keyword: dental alloy

Search Result 489, Processing Time 0.025 seconds

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service (상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례)

  • Lee, Jun-Sik;Han, Se-Jin;Choi, Yu-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2014
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Microstructure and Corrosion Resistance of Ti-15Sn-4Nb Alloy with Hf Adding Element (Hf가 첨가된 생체용 Ti-15Sn-4Nb 합금의 미세조직 및 내식성)

  • Lee, Doh-Jae;Lee, Kyung-Ku;Cho, Kyu-Zong;Yoon, Taek-Rim;Park, Hyo-Byung
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.55-64
    • /
    • 2001
  • This study is focusing on the improvement of problems of Ti-6Al-4V alloy. A new Ti based alloy, Ti-15Sn-4Nb, have designed to examine any possibility of improving the mechanical properties and biocompatibility. Specimens of Ti alloys were melted in vacuum arc furnace and homogenized at $100^{\circ}C$ for 24h. All specimens were solution treated at $812^{\circ}C$ and aged at $500^{\circ}C$ for 10h. The corrosion resistance of Ti alloys was evaluated by potentiodynamic polarization test and immersion test inl%Lactic acid solutions. Ti-15Sn-4Nb system alloys showed Widmanstatten microstructure after solution treatment which is typical microstructure of ${\alpha}+{\beta}$ type Ti alloys. Analysing the corrosion resistance of Ti alloys, it was concluded that the passive films of Ti-15Sn-4Nb system alloys are more stable than that of Ti-6Al-4V alloys. Also, the corrosion resistance of Ti-15Sn-4Nb system alloys was improved with adding elements, Hf. It was analysed that the passive film of the Ti-15Sn-4Nb alloy which was formed in air atmosphere was consisted of TiO2, SnO and NbO through X-ray photoelectron spectroscopy(XPS) analysis.

  • PDF

A Study on the Variation of Tensile Strength and Hardness According to the Frequency of Reuse with Chrome-Cobalt Alloy Widely used in the Production of Partial Denture (국부의치 제작에 사용되는 Chrome Cobalt Alloy의 재주조 횟수에 따른 인장강도 및 경도 변화에 대한 실험적 연구)

  • Chung, Kyung-Pung
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.15-25
    • /
    • 1996
  • This study is to measure and compare the hardness and tensile strength of each time after we recast seven times continually only with and metal alloy Chromium-Cobalt alloy used in the production of partial denture frame work. The result of the experiment were as follow; 1) The result of the hardness measurement The result of the first casting was $490.48{\pm}38.38$ and that of the second recasting was $455.18{\pm}35.61$ and form the third recasting. the result were $518.38{\pm}37.68$ and over. The change of the hardness difference between each recasting was as follow; The hardness difference between the first casting and the second recasting was $35.25{\pm}31.93$ and that between the second recasting and the third recasting was $63.20{\pm}54.02$. There was a statistically significant difference(P<0.01) in the above hardness, however, there was little difference on the whole. And after the third recasting, the hardness grew high a little bit. That is why low-melting metals such as Cr, Mn, Cu of alloy ingredient was evaporated or there was an effect of changes in metal crystal structure, I suppose. 2) The result of the tensile strength measurement. There was a statistically significant difference(P<0.01) between the first casting and the second, the fourth recasting, however. there was little difference in general.

  • PDF

The Surface Property and Shear Bonding Strength according to Composition of Ni-Cr alloy for Porcelain Fused to Metal Crown (도재용착주조관용 Ni-Cr계 합금의 조성에 따른 표면특성 및 전단결합강도 관찰)

  • Kim, Kap-Jin;Chung, In-Sung;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Purpose: This study was to observe surface property and bonding strength according to composition of Ni-Cr alloy for porcelain fused to metal crown. The two kinds of Ni-Cr alloy with different composition ratio of parent metal were observed general properties and chemical properties of each alloy surface and measured the shear bonding strength between ceramic and each alloys. The aim of study was to suggest the material for design of parent metal's composition ratio to development of alloy for porcelain fused to metal crown. Methods: The two kinds of alloy as test specimen was Ni(71wt.%)-Cr(12wt.%) and Ni(63wt.%)-Cr(23wt.%) alloy. The oxide on surface was observed by SEM and EDX. And the shear test was performed by MTS. Results: The surface property and oxide characteristic analysis of oxide layer, weight percentage of Element O within $Ni_{71}Cr_{12}$ alloy measured 12.74wt.%, but $Ni_{63}Cr_{23}$ alloy was measured 15.91wt.%. And the maximum shear bonding strength was measured 106.14MPa between $Ni_{71}Cr_{12}$ alloy and vintage halo (VV group). Conclusion: The surface property and oxide characteristic of $Ni_{71}Cr_{12}$ alloy was similar to $Ni_{63}Cr_{23}$ alloy. And VV group has the strongest shear bonding strength.

Effects of Adding Element Ta, Hf and Heat Treatment on Mechanical Properties of Ti-40Nb Alloys (Ti-40Nb계 합금에 열처리와 첨가원소 Ta, Hf이 기계적 성질에 미치는 영향)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.19-25
    • /
    • 2005
  • Ti6Al4V alloy have been mainly used as implant materials. Ti-6Al-4V alloy instead of pure Ti is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength. But it has been reported recently that vanadium component expresses cytotoxicity and carcinogenicity and aluminium component is related with dementia of Alzheimer type. In order to overcome their detrimental effects, $\beta$-phase stabilizer Nb was chosen in the present study, in addition Ta and Hf were added to Ti-40wt.%Nb alloy to improve its mechanical properties. This paper was described the influence of heat treatment of Ti-40Nb alloys with 2wt%Ta, 2wt%Hf on the mechanical properties. Specimens of Ti alloys were melted in vacuum arc furnace and homogenized at 1050$^{\circ}C$ for 24 hr. and then were aged after solution heat treat at $\alpha+\beta$ and $\beta$ regions. The mechanical properties of Ti alloys were analysed by hardness test, tensile test, elongation test and SEM test. The results can be summarized as follows: 1. The mechanical properties Ti-40wt.%Nb were improved when 2wt.% Ta and 2wt.%Hf were added. 2. The higher tensile strength value and elongation at solution heat treat was higher than solution heat treat and then were aged.

  • PDF

A Research on Evaluation Methods of Testing Impact of the Strength of Soldering (납착강도 충격시험 평가법에 관한 연구)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.55-65
    • /
    • 1999
  • So far, I Conducted an examination with focus on the type, characteristic, and test methods of impact test. which is a type of mechanical that evaluate materials. As mentioned previously, in testing soldering strength of soldering is the load when the object under experiment is broken down with the result of flexibility test or peel test. In this method, a hevay load is necessary until alloy of parent metal is bended, if the alloy of the parent metal has a large mechanical quality(peel strength or resisting power). Once the alloy of the parent metal is bended, however, it tends to come into pieces abruply form the part where soldered. Therefore, a metal has a high breakdown value if the degree of strength of its parent metal is high even if the result of measurement indicates otherwise. Thus, the result of the test did not correspond to the clinical result. Therefore, this study concludes as the following from a test of strength of soldering by mean of conducting an impact test, which is a type of mechanical evaluation methods : 1. Among various impact tests, a charpy thpe is more appropriate than the izod type in testing strength of soldering. 2. As far as test piece is concerned, to use subsized impact test piece is appropriate in the impact test in that it does not have notch. 3. In the matter of analysis, it is appropriate to measure absorbing energy which results from rupture of test piece.

  • PDF

An Experimental Study on Wear of Porcelain Surface to Natural Teeth and Crown Metal Alloys (자연치아 및 치과용 합금에 대한 도재표면 마모에 관한 실험적 연구)

  • Lee, Nung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 1981
  • Dental porcelains are widely used for restorative material because of its excellent esthetic property. But according to contact with natural teeth or metal in oral cavity, the porcelain may be worn and may effect on masticatory physiology and prosthetic function. The purpose of this experiment was to study on wear of porcelain surface which treated in different method. Using the abrasion device which was designed and constructed by myself, the different porcelain surface were abraded by gold alloy, nickel-chrome alloy and natural teeth in order to compare roughness. Results were as follows. 1. The group of porcelain abraded by gold alloy showed less surface roughness change (t=2.92, p<0.05), and the group of porcelain abraded by natural teeth had high surface roughness. change (t=6.84, p<0.05). 2. According to the method of surface treatment, the surface roughness were very significant (F=9.12, p<0.05). 3. After abrading, the porcelain surface roughness change was very significant (F=54.49, p<0.05). 4. There was no significant between surface treatment method and the kind of abrading materials. (F=1.01, p>0..05). 5. The group of natural glazing had the most smooth surface ($2.1{\pm}1.13{\mu}m$).

  • PDF

An Experimental study on the bond strength according to the surface treatment of metal alloy for porcelain fused metal crown (-금속(金屬) 표면처리방법(表面處理方法)에 따른 비귀금속합금(非貴金屬合金)과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 실험적(實驗的) 연구(硏究)-)

  • Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.83-88
    • /
    • 1989
  • This investigation was performed to evaluate the effect of four different preteatment techniques on the bond strength of porcelain to non-precious metal alloy. Samples of total of 40 were divided into 4 groups according to the 4 variables which included the 50$\mu$alumina oxide air abrasion, method, the as retention bead method, the L-retention bead method, the Etching method. The completed metal-porcelain samples were compressed in Instron loading machine until gross fracture occured to examine the effect of the complex variables on the bond strength of porcelain to non precious metal alloy. The result obtained were as follows : 1. The difference of bond strength according to four different pretreatment techniques was statistically significant(p<0.01). 2. The difference of bond strength between the ss-retention bead method and the L-retention bead method was not significant statistically(p>0.05) 3. The difference of bond strength between the retention bead method and the etching method was statistically significant(p<0.01). 4. The difference of bond strength between the retention bead method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01). 5. The difference of bond strength between the etching method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01).

  • PDF

Effect of cooling rate on precipitation hardening of a Pd-Cu-Ga-Zn metal-ceramic alloy during porcelain firing simulation (금속-세라믹용 Pd-Cu-Ga-Zn계 합금의 모의 소성 시 냉각 속도가 석출 경화에 미치는 영향)

  • Kim, Min-Jung;Shin, Hye-Jeong;Kwon, Yong-Hoon;Kim, Hyung-Il;Seol, Hyo-Joung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.207-216
    • /
    • 2017
  • The effect of cooling rate on precipitation hardening of a Pd-Cu-Ga-Zn metal-ceramic alloy during porcelain firing simulation was investigated and the following results were obtained. When the cooling rate was fast (Stage 0), the hardness of the alloy increased at each firing step and the high hardness value was maintained. When the cooling rate was slow (Stage 3), the hardness was the highest at the first stage of the firing, but the final hardness of the alloy after complete firing was lower. The increase in hardness of the specimens cooled at the cooling rate of Stage 0 after each firing step was caused by precipitation hardening. The decrease in hardness of the specimens cooled at the cooling rate of Stage 3 after each firing step was attributed to the coarsening of the spot-like precipitates formed in the matrix and plate-like precipitates. The matrix and the plate-like precipitates were composed of the $Pd_2(Cu,Ga,Zn)$ phase of CsCl-type, and the particle-like structure was composed of the Pd-rich ${\alpha}$-phase of face-centered cubic structure. Through the porcelain firing process, Cu, Ga, and Zn, which were dissolved in Pd-rich ${\alpha}$ particles, precipitated with Pd, resulting in the phase separation of the Pd-rich ${\alpha}$ particles into the Pd-rich ${\alpha}^{\prime}$ particles and ${\beta}^{\prime}$ precipitates composed of $Pd_2(Cu,Ga,Zn)$. These results suggested that the durability of the final prosthesis made of the Pd-Cu-Ga-Zn alloy can be improved when the cooling rate is fast during porcelain firing simulation.

Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness

  • Ayyildiz, Simel;Soylu, Elif Hilal;ide, Semra;Kilic, Selim;Sipahi, Cumhur;Piskin, Bulent;Gokce, Hasan Suat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.471-478
    • /
    • 2013
  • PURPOSE. The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS. Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring $4{\times}2{\times}2$ mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of <.05 were accepted as statistically significant. RESULTS. The general nanostructures of the samples were composed of small spherical entities stacked atop one another in dendritic form. All groups also displayed different hardness values depending on the manufacturing technique. The annealing procedure and environment directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness ($48.16{\pm}3.02$ HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness ($27.40{\pm}3.98$ HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 ${\AA}$). CONCLUSION. After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments.