타이타늄 표면 코팅이 도재 결합에 미치는 영향 (EFFECTS OF TITANIUM SURFACE COATING ON CERAMIC ADHESION)

  • 김연미;김현승;이광민;이도재;오계정;임현필;서윤정;박상원
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.601-610
    • /
    • 2007
  • Statement of problem: The adhesion between titanium and ceramic is less optimal than conventional metal-ceramic bonding, due to reaction layer form on cast titanium surface during porcelain firing. Purpose: This study characterized the effect of titanium-ceramic adhesion after gold and TiN coating on cast and wrought titanium substrates. Material and method: Six groups of ASTM grade II commercially pure titanium and cast titanium specimens$(13mm{\times}13mm{\times}1mm)$ were prepared(n=8). The conventional Au-Pd-In alloy served as the control. All specimens were sandblasted with $110{\mu}m\;Al_2O_3$ particles and ultrasonically cleaned for 5min in deionized water and dried in air before porcelain firing. An ultra-low-fusing dental porcelain (Vita Titankeramik) was fused on titanium surfaces. Porcelain was debonded by a biaxial flexure test at a cross head speed of 0.25mm/min. The excellent titanium-ceramic adherence was exhibited by the presence of a dentin porcelain layer on the specimen surface after the biaxial flexure test. Area fraction of adherent porcelain (AFAP) was determined by SEM/EDS. Numerical results were statistically analyzed by one-way ANOVA and Student-Newman-Keuls test at ${\alpha}=0.05$. Results: The AFAP value of cast titanium was greatest in the group 2 with TiN coating, followed by group 1 with Au coating and the group 3 with $Al_2O_3$ sandblasting. Significant statistical difference was found between the group 1, 2 and the group 3 (p<.05). The AFAP value of wrought titanium was greatest in the group 5 with TiN coating, followed by the group 4 with Au coating and the group 6 with $Al_2O_3$ sandblasting. Conclusion: No significant difference was observed among the three groups (p>.05). The AFAP values of the cast titanium and the wrought titanium were similar. However the group treated with $Al_2O_3$ sandblasting showed significantly lower value (p<.05).

시간경과에 따른 아말감의 부식거동에 관한 연구 (A STUDY ON CORROSION BEHAVIOR OF DENTAL AMALGAMS AS A FUNCTION OF TIME)

  • 이명종;김영해;이정식;윤수한;임성삼;권혁춘;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.6-15
    • /
    • 1991
  • The purpose of this study was to observe in vitro chloride corrosion behavior from 5 kinds of amalgam (Caulk spheracal, Amalcap, Dispersalloy, Tytin, Sybralloy) as a function of time after tritruration by using potentiostat. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by the mechanical amalgamator, the triturated mass was inserted the cyrindrical matal mold ($12{\times}10mm$) and was condensed by using routine manner. The specimen was removed from the mold and was stored at room temperature for 1 week, 1 month and 3 months, and standard surface preparation was routine carried out. The 0.9% saline solution was used as electrolyte in pH 6.8~7.0 at $30{\pm}0.5.^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of 1 week, 1 month and 3 month old specimens. The scan rate was 1 mV/sec and the surface area of amalgam exposed to the solution was $0.65\;Cm^2$ for each specimen. All potentials reported are with respect to a silver / silver chloride electrode (SSE). The following result was obtained. 1. All amalgam specimens became more noble corrosion potentials which represent the improved corrosion resistance as the time elapsed. 2. Three kinds of high copper amalgam always exhibited more noble potential than low copper amalgam at 1 week, 1 month and 3 months. 3. Two kinds of low copper amalgam had the similar polarization curve pattern with 3 current peaks at each time period and current densities associated with these peaks were decreased as aging especially in caulk spherical amalgam. 4. All kinds of high copper amalgam had the similar polarization curve pattern with absence of prominent current peak at each time period, but the polarization curve of D amalgam had one apparent current peak at 1 week.

  • PDF

인공타액에서 아말감의 부식거동에 관한 전기화학적 연구 (ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA)

  • 김영남;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

분할 정위방사선 치료 시스템 개발 연구 (Development of A Fractionated Stereotactic Radiotherapy System)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2002
  • 두부 프레임을 지지하는 방식으로 pedestal mounting system과 couch mounting system의 장점을 수용한, 새로운 형태의 분할 정위방사선 치료 시스템을 개발하였다. 두부 고정을 위한 프레임은 두랄루민으로 제작하였고, 카우치에 부착되게 하였다. 프레임 내에서 환자의 두부를 고정하기 위해 치아 고정장치와 3.2 mm 열프라스틱으로 전두부와 후두부에 마스크를 제작할 수 있다. 정위 좌표 구현을 위한 전산화 단층촬영 localizer는 각 병원에서 많이 사용하고 있는 Brown-Roberts-Walls(B.R.W) 시스템을 사용할 수 있게 하여, 개발된 시스템의 신뢰성을 높이고 제작 단가도 낮추고자 하였다. 프레임 mounting system은 pedestal mounting system을 수정, 보완한 형태로 개발하였다. 시스템은 카우치를 지지하는 바닥 면에 고정되어 카우치에 부착된 프레임과 결합할 수 있고, 시스템과 카우치의 잠금 장치를 푼 채 자유롭게 x, y축으로 유동할 수 있다. 프레임 mounting system의 중심축은 상, 하 방향으로 이동 가능한 포인터 형태로 제작하여, 치료기의 구동 정확성을 검증하는 정도 관리에 응용 가능하다. 개발된 시스템의 재현성과 정확도 검증을 위해 아크릴 팬텀과 포인터를 제작하였고, 전산화 단층촬영 영상에서 획득한 팬텀 내 목표점의 정위 좌표를 dial-gauge와 E.C.L 필름으로 검증하였다. 실험의 결과 x축 방향의 재현성 오차는 0.71$\pm$0.19 mm, y축 방향은 0.45$\pm$0.15 mm, z축 방향 재현성 오차는 0.63$\pm$0.18 mm로 나타났고, 최대 1.3 mm 이내의 우수한 재현성을 보였다. 연구 결과로 개발된 분할 정위방사선 치료 시스템은 재현성이 우수하고, 전체 중량이 가벼워 사용하기 쉽게 제작되었다. 특히 수정된 pedestal frame mounting system으로 설계되어 후두부 방사선 조사가 가능한 장점이 있다.

  • PDF

유한요소법을 이용한 전부주조관의 교합점 위치와 하중방향이 시멘트층 내 응력에 미치는 영향 (Characterization of the Stresses in the Luting Cement Layer Affected by Location of the Occlusal Points and Loading Direction on a Full Veneer Crown)

  • 이정훈;이규복;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.317-324
    • /
    • 2008
  • 이 논문의 목적은 전부주조관에서 교합점의 위치와 교합력의 방향이 합착용 시멘트층 내의 응력에 미치는 영향에 대해서 알아보는 것이다. 하악 제 1대구치상에서 서로 다른 9 개의 교합점과 3가지 교합력 방향을 가진 27가지 조합의 유한요소 모델을 상정하였다. 금관의 소재는 제 3형 금합금이고, 변연의 형태는 chamfer이다. 합착용 시멘트로는 전 층에서 균일하게 $70{\mu}m$의 두께를 가지는 글라스 아이오노머 시멘트가 사용되었다. 금관에는 100N의 하중을 적용하였다. 협측과 설측 변연의 근접도에 따라서 시멘트층 내 응력은 다른 양상을 나타내었다. 협측은 변연으로부터 약 0.5 mm, 설측은 변연으로부터 약 1 mm 내측에서 최대 응력 값을 가졌다. 하중 방향이 치축에 대해 경사가 클수록, 하중점이 교두첨에 근접해 있을수록 더 큰 응력이 발생하였다.

임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰 (A literature review on implant abutment and soft tissue response)

  • 이영훈;고경호;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 지대주의 재료와 표면에 따라 연조직반응이 다르고 임플란트 주위염의 원인이 될 수 있다. 티타늄과 지르코니아는 우수한 생체적합성을 가져 안정적인 연조직반응을 보이고 금합금은 표면상태에 따라 연조직반응이 다르게 나타난다. 같은 재료라도 표면특성에 따라 연조직반응이 영향을 받는다. 표면거칠기 증가는 박테리아 부착을 유발하므로 연조직과 접촉하는 부분은 평활한 표면을 가져야 한다. 추가적인 표면처리를 통해 박테리아의 부착은 증가시키지 않으면서 세포반응을 촉진시킬 수 있다. 지대주의 형태 및 반복착탈도 연조직반응에 영향을 줄 수 있다. 초음파 세척과 아르곤 플라즈마 처리는 비교적 효과적으로 맞춤형 지대주의 잔류 미세입자를 제거할 수 있는 방법이다.

골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구 (Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration)

  • 황갑운
    • 한국융합학회논문지
    • /
    • 제12권12호
    • /
    • pp.145-151
    • /
    • 2021
  • Ti Gr4에 TPS 법을 이용하여 HA 코팅을 수행하여 코팅층에 대한 물리적특성 및 생체적합성을 판단하여 의료용 부품으로서의 활용성에 대한 평가를 하였다. 직경 25mm Ti Gr4 합금 시험편을 기계가공 후 #120, #400, #1,000 샌드페이퍼 및 바렐 연마로 표면을 연마를 하여 ASTM F1185-88로 HA 코팅은 한 후 HA 코팅층의 두께, 표면조도, 강도 및 접착력 측정 시험과 세포독성 시험을 하였다. Ti Gr4에 대한 HA 코팅 결정도는 75.51%, Ca/P 비는 1.67의 값을 얻을 수 있었다. HA 코팅층의 두께는 Ti 소재의 표면거칠기가 거칠수록 증가하고, 코팅의 강도 및 접착력은 시험장치의 지그 형상, 에폭시 성분, 크로스헤드 속도 등에 따라 변화가 있을 것으로 예측된다. 세포독성 시험은 Grade 3의 반응성으로 적합한 것으로 나타났다. 본 실험 결과 TPS에 의한 Ti Gr4 소재의 HA 코팅 두께 향상과 골융합을 촉진이 가능할 것으로 확인되어 인체삽입용으로 상용화가 가능할 것으로 판단된다.

고투명도 지르코니아의 두께 및 하부 배경에 따른 색조 차단 효과 (Effects of thickness and background on the masking ability of high-trasnlucent zirconias)

  • 김영곤;정지혜;공현준;김유리
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.199-208
    • /
    • 2021
  • 목적: 이 연구의 목적은 고투명도 3종류의 지르코니아의 두께 및 하부 배경에 따른 색조 차단 효과를 비교, 평가하는 것이다. 연구 재료 및 방법: 3 종류의 고투명도 지르코니아(Ceramill zolid fx white, Ceramill zolid ht+ white, Ceramill zolid ht+ preshade A2)를 각각 CAD/CAM 방식으로 직경 10 mm의 원판 형태의 4가지 두께(0.6 mm, 1.0 mm, 1.5 mm, 2.0 mm)로 10개씩 시편을 제작하였다. 하부 배경은 직경 10 mm, 두께 10 mm로 A1, A2, A3 레진 하부 배경, 청색의 코어 레진 하부 배경, Ni-Cr 합금 하부 배경을 제작하였으며, 추가로 분광 광도계 제조사에서 제공하는 검정색 및 흰색 하부 배경을 사용하였다. 지르코니아 시편과 기준 배경을 접착제없이 겹쳐 분광 광도계로 L, a*, b* 값을 측정하고 다른 하부 배경과의 ΔE 값을 계산하였다. 계산된 평균 ΔE 값을 인지 한계 1.0과 허용 한계 3.7 값을 기준으로 색조 차단 효과를 비교하였다. 통계적 유의성 검증을 위해 비모수 검정인 Kruskal-Wallis 검정을 시행하였다(α = 0.05). 결과: 지르코니아 종류, 하부 배경 및 두께 변화에 따른 평균 ΔE 값의 유의한 차이를 보였다(P = 0.000). 결론: 본 연구 결과에 의하면, 색조를 가지는 고투명도 지르코니아는 청색 레진 코어를 제외한 치아, 복합레진 및 지대주상에 수복될 때 원하는 지르코니아 색조를 얻을 수 있다.

금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구 (Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis)

  • 조재영;강선녀;정창모;윤미정;허중보;전영찬
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.29-35
    • /
    • 2012
  • 연구 목적: 임플란트-골 계면에서 발생하는 과도한 열은 골유착을 저해하여 임플란트의 실패를 유발한다. 이에 이번 연구에서는 임플란트 금 합금 보철물의 교합면 삭제시 임플란트-골 계면으로의 열전달 양상과 냉각 방식의 효율성을 알아 보고자 하였다. 연구 재료 및 방법: 온도 감지 장치 제작을 위하여 Internal cone 연결형태의 임플란트에 16개의 K형 열전대를 부착하여 아크릴릭 레진에 포매하였다. 치과용 금 합금과 주조용 abutment를 사용하여 교합면에 3개의 요철을 가지는 시편을 10개 제작하였고, 연결 나사를 이용하여 임플란트와 연결한 뒤 온도 감지 장치를 $37^{\circ}C$ 유지되는 수조에 위치시켰다. 저속 핸드피스와 green stone bur를 이용하여 30초 동안 보철물의 요철을 삭제하였는데, 무냉각군, 공기 냉각 군, 물 분사 냉각 군으로 나누어 요철을 삭제하였다. 보철물이 삭제 되는 동안 임플란트의 부위별로 온도가 0.05초 간격으로 기록되었고, 삭제를 멈춘 뒤에도 무 냉각 군의 경우 임계 온도인 $47^{\circ}C$ 이하로 온도가 하강할 때까지, 공기 냉각군과 물 분사 냉각군의 경우 삭제 중단 후 30초 동안 추가로 온도를 기록하였다. 냉각 방식에 따른 임플란트-골 계면의 온도를 알아보고, 임플란트의 부위별 온도변화의 유의차를 알아보기 위하여 one-way ANOVA를 실시하였고, Turkey HSD 이용하여 95% 유의수준에서 사후 검증하였다. 결과: 무 냉각 군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이상으로 상승하였으며, 임플란트의 경부에서 유의하게 높은 열이 측정되었다(P>.05). 공기냉각군과물분사냉각군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이하로 유지되었다. 무 냉각 군에서 임플란트 경부의 온도가 $47^{\circ}C$에 도달되는 데는 약 $10.8{\pm}1.5$초가 소요되었다. 공기 냉각 군과 물 분사 냉각 군 사이에서는 임플란트-골 계면 온도의 유의차가 없었다(P>.05). 결론: 이상의 결과로부터 임플란트 금 합금 보철물의 교합면 삭제 시, 임플란트 주위 조직에 위해를 가할 수 있는 임계 온도 이상의 열이 발생했음을 알 수 있었으며, 냉각 방식은 공기 냉각과 물 분사 냉각 모두 효과적이라고 생각된다.