• Title/Summary/Keyword: dental Implants

Search Result 1,477, Processing Time 0.028 seconds

ORIGINAL ARTICLE - Analysis of RFA related to stabilities by types and areas of dental implants (ORIGINAL ARTICLE - 임플란트 종류 및 식립부위에 따른 안정성에 대한 RFA 분석)

  • Yi, Hee-Yong;Park, Min-Ju;Cho, Hyun-Jae;Yu, Ki-Jun;Ha, Jung-Eun;Baek, Dae-Il;Bae, Gwang-Hak
    • The Journal of the Korean dental association
    • /
    • v.50 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • Objective : This research compared stabilities between two types of dental implant ($SLA^{TM}$, Institut Straumann AG, Waldenburg, Switzerland and $SSII^{TM}$, Osstem co, Busan, Korea) using Osstell Mentor (Integration Diagnostics AB, Goteborg, Sweden) considering surgery methods, surgery area, diameter of implant, systemic disease, and smoking for obtaining prognosis information when installing fixture of dental implant. Materials & Methods : 206 implants of 131 patients taken by resonance frequency analysis (RFA) were determined as a final sample. Dental implants were installed as protocol of supplier by a excellent dentist who had 10 years experience about dental implants. Before connecting abutments (3 months after installation of fixture), RFA were measured twice for buccal and lingual direction to obtain average value. Results : Dental implants at mandible showed significantly higher stabilities significantly than at maxilla (p<0.001). Diameter 4.8 implants had also higher stabilities than diameter 4.1 in case of $SLA^{TM}$ implants (p<0.001). $SLA^{TM}$ implants showed more excellent stabilities than $SSII^{TM}$ implants, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032). Conclusions : This research revealed higher stabilities of $SLA^{TM}$ implants than $SSII^{TM}$ implant, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032).

Structural Design of a Dental Implant (I): Comparative Structural Analysis (치과용 임플란트 구조설계 (1): 구조해석 비교연구)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.421-432
    • /
    • 2012
  • This paper is the first paper among two papers which constitute the paper about the structural design of a dental implant. This paper surveyed types and characteristics of dental implants. Merits and shortcomings of clinically used dental implants were analysed through this survey. A new structural model of dental implant was proposed on the basis of survey results. Especially, a comparative structural analysis of the new dental implant and the well known dental implants has been performed using the finite element analysis method. The analysis results confirm that the newly proposed dental implant has a good structural performance. The well known dental implants used for the comparative structural analysis are 3i implant and Sargon implant. These implants are imported dental implants and we could know that most implants clinically used are endosteal implants and these two implants(3i implant and Sargon implant) are also endosteal implants.

Long-term Retrospective Study on Cumulative Survival Rate of Implants with Guided Bone Regeneration (골유도재생술을 동반한 임플란트의 생존율에 대한 연구)

  • Jung, Suk-Hyun;Kim, Jun-Hwan;Namgung, Da-Jeong;Kim, Yun-Jeong;Chung, Jaeeun;Ku, Young
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.196-209
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze the cumulative survival rate of dental implants installed with guided bone regeneration (GBR), and also elucidate the factors related with the survival of dental implants. Material and Methods: This retrospective study was conducted on 148 dental implants installed in 76 patients by one specialist (Y.K.) at the Department of Periodontology and Implant Center, Seoul National University Dental Hospital from 2001 to 2010. The cumulative survival rates were obtained by the Kaplan-Meier method. The correlations between various factors and dental implant survival were analyzed by using the log-rank test and Cox proportional hazards model. Results: Among 148 dental implants installed in 76 patients, 8 implants in 7 patients were lost and the cumulative survival rates up to 5-years and 10-years were 97% and 89%, respectively. Gender, smoking status and location of implant were significantly associated with the cumulative survival rate of implants (p < 0.05). Age, history of hypertension and diabetes were not significantly associated with the cumulative survival rate of implants (p > 0.05). Conclusion: The dental implants installed with guided bone regeneration is predictable technique according to the results of cumulative survival rate over 10 years.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

Prediction model for dental implants utilization in the elderly after the national health insurance coverage of dental implants: focusing on socioeconomic factors (치과 임플란트 국민건강보험 급여화 이후 노인의 치과 임플란트 이용에 대한 예측 모형: 사회경제적 요인 중심으로)

  • Sang-Hee Lee;Kyu-Seok Kim;Hye-Young Mun;Jung-Yun Kang
    • Journal of Korean society of Dental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • Objectives: The demand for dental care is expected to increase as the population ages. This study aimed to predict the utilization of dental implant care following the expansion of national health insurance benefits for dental implants. Methods: Multiple linear regression analysis was performed on HIRA big data open portal data and DNN-based artificial intelligence models to forecast the utilization of dental care in relation to the national health insurance coverage for dental implants. Results: National health insurance coverage of dental implants was found to be associated with the number of patients using dental implant services and demonstrated a statistical significance. The dental implant services utilization increased with the increased dental implant health insurance benefits for the elderly population, increased mean by region, increased number of dental institutions by region, and increased health insurance coverage rate for dental implants. However, the dental implant services utilization decreased with the increased number of older people living alone and increased size of dental institutions. Conclusions: With the expansion of the national health insurance coverage for dental implants, it is predicted that the utilization of dental implant medical services will increase in the future.

Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Cha, Jae-Won;Kim, Eun-Ja;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.371-378
    • /
    • 2012
  • Many longitudinal studies have reported the successful osseointegration of dental implants, with survival rates approaching 90-95%. However, implants regarded as a "success" may have also failed to undergo osseointegration. A variety of complications and failures have been observed, including implant fracture - a rare and delayed biomechanical complication with serious clinical outcomes. Given the increasing popularity of dental implants, an increase in the number of failures due to late fractures is expected. This study sought to determine the rate of implant fractures and factors associated with its development. This retrospective evaluation analyzed implants placed at Wonkwang Dental Hospital (from 1996 to the present). In our study we found that the frequency of dental implant fractures was very low (0.23%, 8 implant fractures out of 3,500 implants placed). All observed fractures were associated with hybrid-surface threaded implants (with diameter of 4.0 or 3.75 mm). Prosthetic or abutment screw loosening preceded implant fracture in a majority of these cases.

RETROSPECTIVE STUDY OF SINTERED POROUS-SURFACED DENTAL IMPLANTS IN RESTORING THE POSTERIOR MAXILLA (상악 구치부에 식립된 엔도포아 임플란트의 후향적 연구)

  • Kim, Sang-Soo;Ahn, Mi-Ra;Lee, Won-Hyuk;Jung, Heui-Seung;Shin, Im-Hee;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.361-366
    • /
    • 2009
  • Purpose: The purpose of this retrospective report was to analyze long-term survival rate of sintered porous-surfaced dental implant ($Endopore^{(R)}$ Dental Implant system, Innova Corporation, Toronto, ON, Canada). Methods: 61 partially edentulous patients were received a total of 127 Endopore dental implants in the maxilla. Of the 127 implants, 24 implants were restored with individual (ie, non-splinted) crowns, while 103 implants were splinted to other implants. Medical records and radiographs were evaluated and analyzed by the cumulative survival rate, location of implants, implants length and diameter, crown/implant ratio and whether the implant was splinted. Chi squire test was used statistically. Result: Of the 127 implants, 8 implants (6.3%) were removed and and cumulative survival rate was 93.7%. Conclusion: Endopore implants showed satisfactory results after up to 8 years function periods in the edentulous posterior maxilla.

RETROSPECTIVE STUDY OF SHORT ROUGH SURFACE IMPLANTS (짧은 길이의 거친 표면 임프란트에 대한 후향적 연구)

  • Kong, Jun-Ha;Lee, Baek-Soo;Kim, Yeo-Gab;Kwon, Yong-Dae;Yoon, Byung-Wook;Choi, Byung-Joon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2009
  • Background: Reduced bone height is one of the major problems faced in restoring tooth loss with implants. By the use of short implants, it is possible to reduce complicated and invasive treatment such as bone graft, allowing more simple surgery. But short implants are generally considered to have lower success rates than that of standard implants. Purpose: To assess the results of short Straumann implants by a retrospective study of short Straumann implants with TPS(titanium plasma-sprayed) and SLA(sandblasted, large grit, acid etched) surfaces. Materials and methods: 173 implants in 106 patients who received short Straumann implant surgery(${\le}8\;mm$) in the department of oral and maxillofacial surgery, Kyunghee Dental Hospital, from February 1996 to October 2006 were selected and studied. All of the implants were followed up after prosthetic rehabilitation. The average follow-up period was 34 months with 119 months as the longest follow up period. The average follow-up period after prosthetic rehabilitation was 31 months. 64 females(60.4%) and 42 males(39.6%) participated in the research with the age range of 19 to 85(mean age 47). 20 patients(18.9%) were under 40, 85 patients(80.2%) were over 40 and under 70, and only one patient(0.9%) was over 70 years old. Results: 27 implants(15.6%) had TPS surface while 146 implants(84.4%) had SLA surface. 9 implants(5.2%) were 3.3, 108 implans(62.4%) were 4.1mm and 56 implants(32.4%) were 4.8mm in diameter. 167 implants(96.5%) were 8mm and 6 implants(3.5%) were 6mm in length. There were 24 implants(13.9%) on the maxillas and 149 implants(68.8%) on the mandibles. 119 implants(68.8%) were rehabilitated with FPD(fixed partial denture), 47 implants(27.2%) with single crowns and 4 implants(2.3%) with overdentures. Among the fixed partial dentures, 30 of them were splinted with short implants only. After over an year of follow-up period, 139 implants(96.5%) out of 144 implants showed marginal bone loss of less than 1mm. 3 out of 173 implants failed showing 98.27% survival rate. Conclusions: The use of short Straumann implants(${\le}8mm$) can be a simple and reliable treatment method in minimal residual bone height.

Clinical and radiographic evaluations of implants as surveyed crowns for Class I removable partial dentures: A retrospective study

  • Yoo, Soo-Yeon;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.108-121
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate survival rates and marginal bone loss (MBL) of implants in IC-RPDs. MATERIALS AND METHODS. Seventy implants were placed and used as surveyed crowns in 30 RPDs. The survival rates and MBL around implants based on multiple variables, e.g., position, sex, age, opposing dentitions, splinting, type of used retainer, and first year bone loss, were analyzed. Patient reported outcome measures (PROMs) regarding functional/esthetic improvement after IC-RPD treatment, and complications were also inspected. RESULTS. The 100% implant survival rates were observed, and 60 of those implants showed MBL levels less than 1.5 mm. No significant differences in MBL of implants were observed between implant positions (maxilla vs. mandible; P = .341) and type of used retainers (P = .630). The implant MBL of greater than 0.5 mm at 1 year showed significantly higher MBL after that (P < .001). Splinted implant surveyed crowns showed lower MBL in the maxilla (splinted vs. non-splinted; P = .037). There were significant esthetic/functional improvements observed after treatment, but there were no significant differences in esthetic results based on implant position (maxilla vs. mandible). Implants in mandible showed significantly greater improvement in function than implants in the maxilla (P = .002). Prosthetic complication of IC-RPD was not observed frequently. However, 2 abutment teeth among 60 were failed. The bone loss of abutment teeth was lower than MBL of implants in IC-RPDs (P = .001). CONCLUSION. Class I RPD connected to residual teeth and strategically positioned implants as surveyed crowns can be a viable treatment modality.