• Title/Summary/Keyword: density separation

Search Result 437, Processing Time 0.023 seconds

An ELISA-on-a-Chip Biosensor System for Early Screening of Listeria monocytogenes in Contaminated Food Products

  • Seo, Sung-Min;Cho, Il-Hoon;Kim, Joo-Ho;Jeon, Jin-Woo;Oh, Eun-Gyoung;Yu, Hong-Sik;Shin, Soon-Bum;Lee, Hee-Jung;Paek, Se-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2993-2998
    • /
    • 2009
  • An enzyme-linked immunosorbent assay (ELISA)-on-a-chip (EOC) biosensor combined with cell concentration technology based on immuno-magnetic separation (IMS) was investigated for use as a potential tool for early screening of Listeria monocytogenes (L. monocytogenes) in food products. The target analyte is a well-known pathogenic foodborne microorganism and outbreaks of the food poisoning typically occur due to contamination of normal food products. Thus, the aim of this study was to develop a rapid and reliable sensor that could be utilized on a daily basis to test food products for the presence of this pathogenic microorganism. The sensor was optimized to provide a high detection capability (e.g., 5.9 ${\times}\;10^3$ cells/mL) and, to eventually minimize cultivation time. The cell density was condensed using IMS prior to analysis. Since the concentration rate of IMS was greater than 100-fold, this combination resulted in a detection limit of 54 cells/mL. The EOC-IMS coupled analytical system was then applied to a real sample test of fish intestines. The system was able to detect L. monocytogenes at a concentration of 2.4 CFU/g after pre-enrichment for 6 h from the onset of cell cultivation. This may allow us to monitor the target analyte at a concentration less than 1 CFU/g within a 9 h-cultivation provided a doubling time of 40 min is typically maintained. Based on this estimation, the EOC-IMS system can screen and detect the presence of this microorganism in food products almost within working hours.

Luminescence Detection Characteristics for Irradiated Dried Fishes Using PSL-TL System (Photostimulated luminescence-thermoluminescence 분석체계를 이용한 조사 처리된 건어류의 luminescence 판별 특성)

  • Kim, Moon-Young;Kim, Gui-Ran;Ahn, Jae-Jun;Park, Kun-Sang;Kim, Eun-Jeong;Lee, Kyung-Jin;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.8-12
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were conducted for the detection of different irradiated dried fishes. All the non-irradiated samples provided PSL counts of lower than 700 (negative: $T_1$). Clear identification of irradiated sample was only possible for irradiated anchovy with PSL counts >5000; however, the results were unsatisfactory (not positive) for irradiated cod, dried filefish, hairtail, and herring samples. The contaminating silicate minerals were obtained by density separation or acid hydrolysis to perform TL analysis, which resulted in a low intensity of TL glow curve with a maximum peak after $250^{\circ}C$ for the non-irradiated samples that are irrespective of their kinds and methods for the mineral separation. The TL glow curves of high intensity with maximum peak in the temperature range of $150-250^{\circ}C$ were observed for all the irradiated samples. However, better results of TL glow curves and particularly of the TL ratio ($TL_1/TL_2$) were obtained when the minerals were separated by a acid hydrolysis method.

A Study on Flow Characteristic due to the Periodic Velocity Fluctuation of Upstream at Single Tube (단일 원관에서 전방류의 주기적인 속도 변동에 따른 유동 특성에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.613-618
    • /
    • 2019
  • The flow-induced vibration in a heat exchanger may cause the damage to piping. Therefore, it is necessary to establish the flow induced vibration characteristics for the structural stability of a heat exchanger. The purpose of this study was to compare the generation, development, and separation characteristics of a vortex around a circular tube with respect to time when the flow velocity of the inlet was fluctuating constantly and periodically. The time characteristics of lift and drag and the PSD characteristics were also investigated. In the case of a constant inlet flow velocity, the well-known Kalman vorticity distribution was shown. The vortex generation, growth, and separation were also observed alternately at the upper and lower sides of the tube. In the case of periodic inlet flow velocity, the vortex occurred simultaneously in the upper and lower sides of the tube. In the case of constant inlet flow velocity, the magnitude of the lift PSD was 500 times larger than that of drag. The frequency was 31.15 Hz and that of drag was doubled at 62.3 Hz. In case of a periodic inlet flow velocity, the PSD of the drag was approximately 500 times larger than that of lift. The frequency was 15.57 Hz, which was the same as the inlet-flow velocity frequency. In addition, the frequency of lift was 31.15 Hz, which was the same Karman vortex frequency.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Evaluation of the Flux According to Membrane Distillation Module Structure and Operating Conditions Using PVDF Hollow Fiber Membrane (PVDF 중공사 분리막을 이용한 MD 모듈 구조 및 운전 조건에 따른 플럭스 영향 평가)

  • Min, Ji Hee;Lee, Seul ki;Gil, Nam Seok;Park, Min Soo;Kim, Jin Ho
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.83-89
    • /
    • 2018
  • Hydrophobic porous PVDF hollow fiber membranes for Membrane Distillation (MD) were fabricated by a combination of thermally induced phase separation (TIPS) and stretching. The purpose of this study is to investigate the shape and operating conditions of the module and the effect of piping size on parallel connection. In the optimization experiment of the vacuum membrane distillation module, the flux decreased as the packing density and length of the membrane in the module increased. When the module was connected vertically, it was confirmed that the nearest to the inlet of the vacuum port was the highest flux. In selecting the size of the header pipe of the module, it was confirmed that the maximum flux is shown when the inner diameter area of the hollow fiber membrane and the inner diameter area of the header pipe are the same. Also, it is necessary to find the optimal linear velocity because the higher the linear velocity in the module, the higher the flux, but the pressure acting on the module also increases proportionally.

Effects of Guisinhwan on the Ovariectomized Rat Model of Postmenopausal Osteoporosis (귀신환이 난소적출 백서의 골다공증에 미치는 영향)

  • Kim Tae Hee;Kang Young Keum;Ahn Kyu Hwan;Kim Song Baeg;Cho Han Baek;Yoo Sim Keun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.5
    • /
    • pp.1476-1484
    • /
    • 2004
  • Aging is characterized by an age-dependent reduction in bone density. Pronounced bone loss by postmenopausal estrogen deficiency induces a bad effect on dynamic balance of bone metabolism. When the bone density is reduced to the level below the fracture threshold, the risk for fracture is greatly increased. The purpose of this study is to examine what are the effects of the Guisinhwan(GSH : 歸腎丸) on the ovariectomized rat model of postmenopausal osteoporosis. The results of the experiment are as follows: Body weight in control group showed significant increase in comparison with sham, but that in GSH-treated showed no change in comparison with control. The level of serum albumin in control group showed significant decrease in comparison with sham. That in GSH-treated was slightly decreased in comparison with control. The level of serum ALP activity in control group showed significant increase in comparison with sham, but that in GSH-treated was significantly decreased in comparison with control. The level of serum phosphorous, calcium, GOT, GPT, T3 did not significant change among the three groups. The level of serum estrogen in control group showed slightly decreased in comparison with sham, but that in GSH-treated showed no change in comparison with control. The level of serum T4 in control group showed significant increase in comparison with sham, but that in GSH-treated was significantly decreased in comparison with control. Trabecular bone area as well as trabecular thickness in control group showed significant decrease In comparison with sham. Those in GSH-treated showed significant increase in comparison with control. Trabecular number did not significant change among the three groups. Trabecular separation only in GSH-treated showed significant decrease in comparison with control. Osteoclast number in control group showed significant increase in comparison with sham. That in GSH-treated showed significant decrease in comparison with control. Oseoblast surface in control group showed significant increase in comparison with sham, but that in GSH-treated showed no change in comparison with control. According to the above these results, GSH has shown to be capable of preventing and curing osteoporosis caused by old-aged and postmenopause.

Refinement of Phosphogypsum by Selective Dehydration & Hydration (수화특성차이(水和特性差異)를 이용(利用)한 인산부생석고(燐酸副生石膏)로부터 정제석고(精製石膏)의 회수(回收))

  • Lee, Jung-Mi;Song, Young-Jun;Park, Charn-Hoon
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.46-57
    • /
    • 2006
  • This study was carried out for the purpose of recovering the refined gypsum from waste phosphogypsum. The refined gypsum was recovered as a under product of 325 mesh wet screening followed by dehydration and hydration stage. The influence of dehydration temperature and time, dehydration rate, aging time, slurry density of hydration and sonication time on the yield and grade of gypsum were investigated. The refined gypsum of $94{\sim}96%$ grade is recovered in 95% yield by wet screening after selective dehydration and hydration process, from the phosphogypsum. For the better separation efficiency of gypsum, it is recommended to treat the phosphogypsum at the conditions of as follows; 6hr's dehydration at $140^{\circ}C$, hydration slury density of $3{\sim}10%$, hydration temperature of $20{\sim}30^{\circ}C$, hydration time of 2hr. In additions, addition of sodium citrate 0.005M and sonication of $5{\sim}10min.$ are effective for increase the recovery of gypsum. On the other hand, aging the dehydrated gypsum 16 hours or longer make decrease the recovery of gypsum remarkably.

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.

Effects of Yuklinzu on the ovariectomized rat model of postmenopausal osteoporosis (육린주가 난소적출 백서의 골다공병에 미치는 영향)

  • Choi Sang Soon;Uem Ju O;Kim Song Baek;Yoo Sim Keun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.4
    • /
    • pp.788-800
    • /
    • 2002
  • Aging is characterized by an age-dependent reduction in bone density. Pronounced bone loss by postmenopausal estrogen deficiency induces a bad effect on dynamic balance of bone metabolism. When the bone density is reduced to the level below the fracture threshold, the risk for fracture is greatly increased. The purpose of this study is to examine what are the effects of the Yuklinzu(YLZ: 毓麟珠) on the ovariectomized rat model of postmenopausal osteoporosis. The results of the experiment are as follows: Body weight in control group showed significant increase in comparison with sham, but that in YLZ-treated showed no change in comparison with control. The level of serum albumin in control group showed significant decrease in comparison with sham. That in YLZ-treated was slightly decreased in comparison with control. The level of serum ALP activity in control group showed significant increase in comparison with sham, but that in YLZ-treated was significantly decreased in comparison with control. The level of serum phosphorous in control group showed significant increase in comparison with sham, but that in YLZ-treated showed no change in comparison with control. The level of serum calcium in control group showed no change in comparison with sham, but that in YLZ-treated was significantly decreased in comparison with control. The level of serum GOT in control group showed no change in comparison with sham, but that in YLZ-treated was significantly decreased in comparison with control. The level of serum GPT did not significant change among the three groups. The level of serum estrogen in control group showed slightly increased in comparison with sham, but that in YLZ-treated showed no change in comparison with control. The level of serum T3 in control group showed no change in comparison with sham, and that in YLZ-treated showed no change in comparison with control. The level of serum T4 in control group showed significant increase in comparison with sham, but that in YLZ-treated was significantly decreased in comparison with control. Mechanical strength of the femur neck in control group showed significant decrease in comparison with sham. That in YLZ-treated showed slightly increased in comparison with control. Trabecular bone area as well as trabecular thickness in control group showed significant decrease in comparison with sham. Those in YLZ-treated showed significant increase in comparison with control. Trabecular number and did not significant change among the three groups. Trabecular separation only in YLZ-treated showed significant decrease in comparison with control. Osteoclast number and oseoblast surface in control group showed significant increase in comparison with sham. Those in YLZ-treated showed slightly decreased in comparison with control. According to the above these results, YLZ has shown to be capable of preventing and curing osteoporosis caused by old-aged and postmenopause.