• Title/Summary/Keyword: density ratio estimation

Search Result 125, Processing Time 0.02 seconds

A Novel Position Sensorless Speed Control Scheme for Permanent Magnet Synchronous Motor Drives

  • Won, Tae-Hyun;Lee, Man-Hyung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.125-132
    • /
    • 2002
  • PMSMS (permanent magnet synchronous motors) are widely used in industrial applications and home appliances because of their high torque to inertia ratio, superior power density, and high efficiency. For high performance control, accurate informations about the rotor position is essential. Sensorless algorithms have lately been studied extensively due to the high cost of position sensors and their low reliability in harsh environments. A novel position sensorless speed control for PMSMs uses indirect flux estimation and is presented in this paper. Rotor position and angular velocity are estimated by the proposed indirect flux estimation. Linkage flux and magnetic field flux are calculated by the voltage equations and the measured phase current without any integration. Instead of linkage flux calculation with integral operation, indirect flux and differential magnetic field are used for the estimation of rotor position. A proper rejection technique fur current noise effect in the calculation of differential linkage flux is introduced. The proposed indirect flux detecting method is free from the integral rounding error and linkage flux drift problem, because differential linkage flux can be calculated without any integral operation. Furthermore, electrical parameters of the PMSM can be measured by the proposed TCM (time compression method) for soft starting and precise estimation of rotor position. The position estimator uses accurate electrical parameters that are obtained from the proposed TCM at starting strategy. In the operating region, a proper compensation method fur temperature effect can compensate fir the estimation error from the variation of electrical parameters. The proposed novel position sensorless speed control scheme is verified by the experimental results.

Feasibility study of using triple-energy CT images for improving stopping power estimation

  • Yejin Kim;Jin Sung Kim ;Seungryong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1342-1349
    • /
    • 2023
  • The planning accuracy of charged particle therapy (CPT) is subject to the accuracy of stopping power (SP) estimation. In this study, we propose a method of deriving a pseudo-triple-energy CT (pTECT) that can be achievable in the existing dual-energy CT (DECT) systems for better SP estimation. In order to remove the direct effect of errors in CT values, relative CT values according to three scanning voltage settings were used. CT values of each tissue substitute phantom were measured to show the non-linearity of the values thereby suggesting the absolute difference and ratio of CT values as parameters for SP estimation. Electron density, effective atomic number (EAN), mean excitation energy and SP were calculated based on these parameters. Two of conventional methods were implemented and compared to the proposed pTECT method in terms of residuals, absolute error and root-mean-square-error (RMSE). The proposed method outperformed the comparison methods in every evaluation metrics. Especially, the estimation error for EAN and mean excitation using pTECT were converging to zero. In this proof-of-concept study, we showed the feasibility of using three CT values for accurate SP estimation. Our suggested pTECT method indicates potential clinical utility of spectral CT imaging for CPT planning.

Estimation on Unsaturated Hydraulic Conductivity Function of Jumoonjin Sand for Various Relative Densities (주문진 표준사의 상대밀도에 따른 불포화 투수계수함수 산정)

  • Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2369-2379
    • /
    • 2013
  • The Soil-Water Characteristics Curve (SWCC) is affected by the initial density of soil under unsaturated condition. Also, the characteristic of hydraulic conductivity is changed by the initial density of soil. To study the effect of initial density of unsaturated soil, SWCC and the Hydraulic Conductivity Function (HCF) of Jumoonjin sand with various relative densities, 40%, 60% and 75% were measured in both drying and wetting processes. As the results of SWCC estimated by van Genuchten (1980) model, the parameter related to Air Entry Value(AEV), ${\alpha}$ in the wetting process is larger than that in drying process, but the parameters related to the SWCC slope, n and the residual water content, m are larger than those in wetting process. The AEV is increased or Water Entry Value (WEV) is decreased with increasing the relative density of sand. The AEV is larger than the WEV at the same relative density of sand. As the results of HCF estimated by van Genuchten (1980) model which is one of the parameter estimation methods, the unsaturated hydraulic conductivity maintained at a saturated one in the low level of matric suctions and then suddenly decreased just before the AEV or the WEV. The saturated hydraulic conductivity in drying process is larger than that in wetting process. The saturated hydraulic conductivity is decreased with increasing the relative density of sand in both drying and wetting processes. Also, the hysteresis in unsaturated HCFs between drying and wetting process was occurred like the hysteresis in SWCCs. According to the test results, the AEV on SWCC is decreased and the saturated hydraulic conductivity is increased with increasing the initial density. It means that SWCC and HCF are affected by the initial density in the unsaturated soil.

Dual-Hop Amplify-and-Forward Multi-Relay Maximum Ratio Transmission

  • Erdogan, Eylem;Gucluoglu, Tansal
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the performance of dual-hop multi-relay maximum ratio transmission (MRT) over Rayleigh flat fading channels is studied with both conventional (all relays participate the transmission) and opportunistic (best relay is selected to maximize the received signal-to-noise ratio (SNR)) relaying. Performance analysis starts with the derivation of the probability density function, cumulative distribution function and moment generating function of the SNR. Then, both approximate and asymptotic expressions of symbol error rate (SER) and outage probability are derived for arbitrary numbers of antennas and relays. With the help of asymptotic SER and outage probability, diversity and array gains are obtained. In addition, impact of imperfect channel estimations is investigated and optimum power allocation factors for source and relay are calculated. Our analytical findings are validated by numerical examples which indicate that multi-relay MRT can be a low complexity and reliable option in cooperative networks.

Adaptive maximum power point tracking control of wind turbine system based on wind speed estimation

  • Hyun, Jong-Ho;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.460-475
    • /
    • 2018
  • In the variable-speed wind energy system, to achieve maximum power point tracking (MPPT), the wind turbine should run close to its optimal angular speed according to the wind speed. Non-linear control methods that consider the dynamic behavior of wind speed are generally used to provide maximum power and improved efficiency. In this perspective, the mechanical power is estimated using Kalman filter. And then, from the estimated mechanical power, the wind speed is estimated with Newton-Raphson method to achieve maximum power without anemometer. However, the blade shape and air density get changed with time and the generator efficiency is also degraded. This results in incorrect estimation of wind speed and MPPT. It causes not only the power loss but also incorrect wind resource assessment of site. In this paper, the adaptive maximum power point tracking control algorithm for wind turbine system based on the estimation of wind speed is proposed. The proposed method applies correction factor to wind turbine system to have accurate wind speed estimation for exact MPPT. The proposed method is validated with numerical simulations and the results show an improved performance.

MASS ESTIMATION OF IMPACTING OBJECTS AGAINST A STRUCTURE USING AN ARTIFICIAL NEURAL NETWORK WITHOUT CONSIDERATION OF BACKGROUND NOISE

  • Shin, Sung-Hwan;Park, Jin-Ho;Yoon, Doo-Byung;Choi, Young-Chul
    • Nuclear Engineering and Technology
    • /
    • v.43 no.4
    • /
    • pp.343-354
    • /
    • 2011
  • It is critically important to identify unexpected loose parts in a nuclear reactor pressure vessel, since they may collide with and cause damage to internal structures. Mass estimation can provide key information regarding the kind as well as the location of loose parts. This study proposes a mass estimation method based on an artificial neural network (ANN), which can overcome several unresolved issues involved in other conventional methods. In the ANN model, input parameters are the discrete cosine transform (DCT) coefficients of the auto-power spectrum density (APSD) of the measured impact acceleration signal. The performance of the proposed method is then evaluated through application to a large-sized plate and a 1/8-scaled mockup of a reactor pressure vessel. The results are compared with those obtained using a conventional method, the frequency ratio (FR) method. It is shown that the proposed method is capable of estimating the impact mass with 30% lower relative error than the FR method, thus improving the estimation performance.

Estimation Error of Areal Average Rainfall and Its Effect on Runoff Computation (면적평균강우의 추정오차와 유출계산에 미치는 영향)

  • Yu, Cheol-Sang;Kim, Sang-Dan;Yun, Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.307-319
    • /
    • 2002
  • This study used the WGR model to generate the rainfall input and the modified Clark method to estimate the runoff with the aim of investigating how the errors from the areal average rainfall propagates to runoff estimates. This was done for several cases of raingauge density and also by considering several storm directions. Summarizing the study results are as follows. (1) Rainfall and runoff errors decrease exponentially as the raingauge density increases. However, the error stagnates after a threshold density of raingauges. (2) Rainfall errors more affect to runoff estimates when the density of raingauges is relatively low. Generally, the ratio between estimation errors of rainfall and runoff volumes was found much less than one, which indicates that there is a smoothing effect of the basin. However, the ratio between estimation errors of rainfall to peak flow becomes greater than one to indicate the amplification of rainfall effect to peak flow. (3) For the study basin in this studs no significant effect of storm direction could be found. However, the runoff error becomes higher when the storm and drainage directions are identical. Also, the error was found higher for the peak flow than for the overall runoff hydrograph.

Estimation of Electrical Parameters of OD Organic Semiconductor Diode from Measured I-V Characteristics

  • Moiz, Syed Abdul;Ahmed, Mansoor M.;Karimov, Kh. S.
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.319-325
    • /
    • 2005
  • In this paper the effect of temperature on the electrical properties of organic semiconductor disperse orange dye 25 (OD) have been examined. Thin films of OD have been deposited on $In_{2}O_{3}$ substrates using a centrifugal machine. DC current-voltage (I-V) characteristics of the fabricated devices $(Al/OD/In_{2}O_{3)$ have been evaluated at varying temperatures ranging from 40 to $60^{\circ}C$. A rectification behavior in these devices has been observed such that the rectifying ratio increases as a function of temperature. I-V characteristics observed in $Al/OD/In_{2}O_{3)$ devices have been classified as low temperature $({\leq} 50^{\circ}C)$ and high temperature characteristics (approximately $60^{\circ}C$). Low temperature characteristics have been explained on the basis of the charge transport mechanism associated with free carriers available in OD, whereas high temperature characteristics have been explained on the basis of the trapped space-charge-limited current. Different electrical parameters such as traps factor, free carrier density, trapped carrier density, trap density of states, and effective mobility have been determined from the observed temperature dependent I-V characteristics. It has been shown that the traps factor, effective mobility, and free carrier density increase with increasing values of temperature, whilst no significant change has been observed in the trap density of states.

  • PDF

Physical Parameter Measurement and Theoretical Target Strength Estimation of Juvenile Cod (Gadus macrocephalus)

  • Husni, Iqbal Ali;Hwang, Bo-Kyu;Shin, Hyeon-Ok;Kim, Min-Son
    • Ocean and Polar Research
    • /
    • v.37 no.4
    • /
    • pp.333-340
    • /
    • 2015
  • The contrast (fish body to medium ratio) of density and sound speed were measured to estimate acoustic scattering from small juvenile cod (Gadus macrocephalus) with the Kirchhoff-Ray Mode backscatter model. The density contrast was measured by the density-bottle method and the sound speed contrast was estimated by the time of flight method. The results revealed that the measured density contrasts of juvenile cod varied between 1.003 and 1.029 (mean = 1.014, S.D. = 0.01). On the other hand, sound speed contrasts varied between 1.039 and 1.041 (mean = 1.041, S.D. = 0.001). The relationship between averaged target strength (TS) and total length (TL) established by the model were <$TS_{38kHz}$> = 20log(TL) - 68.8 and <$TS_{38kHz}$> = 20log(TL) - 69.4, respectively.

Control of Hydrocracking Temperature in Ebulated Recycle Reactor (유동화 재순환 반응기에서 석유의 수소첨가 반응시 이탈된 온도제어)

  • 이창우;홍영호;함영민
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.76-87
    • /
    • 1998
  • This study was carried out to investigate the effect of on temperature control from actuating method, recycling ratio and the position (top, middle and bottom) of set and controlled temperature within the reactor in adiabatic ebullated recycling condition, when the disturbance was occurred. Estimation of the solution were performed numerically using the finite difference method. It was assumed that the reaction is in constant with heat of reaction and the physical properties(density, heat capacity and viscosity, etc) of the reactants are same condition within the reactor.

  • PDF