• Title/Summary/Keyword: delayed measurement

Search Result 151, Processing Time 0.029 seconds

HEXKIN : A Quasistatic Approach to Spatial Kinetics Problems in a Hexagonal Lattice Reactor

  • Kim, Hyun-Dae;Oh, Se-Kee;Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.267-273
    • /
    • 1980
  • The quasistatic approximation is incorporated in HEXKIN, a 2-group, 2-dimensional reactor kinetics code specially developed for a hexagonal lattice-type reactor. The code allows maximum 15 delayed neutron groups, 279 lattice points, and 500 different driving functions to be able to initiate perturbation at each lattice point. Reactivity feedback due to power-dependent fuel temperature change is also involved. To check the accuracy of the code, a result of numerical experiment is compared with the measurement at the Savannah River Laboratory. The experiment was specifically designed to emphasize delayed neutron holdback. The calculated flux tilts agree with the measured flux tilts within the small uncertainty of the measurements.

  • PDF

Investigation of Demixing Phenomena of a Polymer Solution During the Phase Inversion Process

  • Han, Myeong-Jin;D. Bhattacharyya
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.11-15
    • /
    • 1995
  • Polysulfone (PS) membranes were prepared by the phase inversion process using water or isopropanol as nonsolvent. The Flory-Huggins theory for a ternary system nonsolvent/solvent/polymer is applied to describe the thermodynamic equilibria of the components. The calculated ternary phase equilibria show that demixing of a PS binary solution with n-methylpyrrolidone (NMP) will be fast in a water coagulation bath and will be delayed in an isopropanol bath. The prepared membranes were characterized by SEM, gas adsorption-desorption measurement, and permeability test. The membrane, which is precipitated by fast demixing in a water bath, has nodular structures in the skin region and includes finger-like cavities in the sublayer. The membrane coagulated by isopropanol has a very dense and thick skin structure, which is formed by delayed demixing. The membrane coagulated by isopropanol showed considerably lower pore volume and surface area compared to that observed with water coagulation method. With dimethylformamide (DMF) as solvent and 2-3 wt% of water, the solution can show the liquid-liquid phase separation due to agglomation of the polymer-lean phase from the homogeneous solution. The membranes, which were coagulated near an equilibrium state, show the large (micron size) round pores in the whole membranes. The pores do not contribute the permeation characteristics.

  • PDF

Effects of HR-AC Techniques and Kinesio Taping on Pain Changes in Delayed Onset Muscle Soreness (지연성근육통에 적용한 HR-AC기법과 키네시오 테이핑이 통증 변화에 미치는 영향)

  • Bae, Sea-hyun;Kim, Kyung-yoon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Background: This study aimed to investigate the effect of hold-relax and antagonist contraction (HR-AC) technique and Kinesio taping on pain changes in delayed-onset muscle soreness (DOMS) of 20's adults. Methods: Based on voluntary participation, 14 participants with induced-DOMS were randomly divided into control (non-treatment, n=7) and experiment group (HR-AC technique and kinesio taping, n=7). Measurement were used visual analogue scale (VAS), heart rate variability (HRV), and brain wave (alpha). There were 5 sets of the HR-AC technique application on the 5th day from the day of DOMS induction (rest for 30s between sets). Kinesio taping was applied to the same area after HR-AC. Results: The VAS showed significant changes according to the period and in the interaction between the period and the group (p<.01). HRV and alpha wave (Fp1) showed significant changes according to the period (p<.001). The analgesic effect was more rapid and continuous in the experimental group than in the control group. Conclusion: This study showed that the HR-AC technique and Kinesio taping are effective interventions for the management of pain and stress caused by DOMS.

Effects of Transcutaneous Electrical Nerve Stimulation and Microcurrent Electrical Neuromuscular Stimulation on Delayed Onset Muscle Soreness (지연성 근육통에 대한 경피신경 전기자극과 미세전류 신경근 자극의 효과 비교)

  • Jung, Young-Jong;Gho, Su-Jeong;You, Hye-Young;Jung, Do-Young
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.76-87
    • /
    • 2000
  • Delayed onset muscle soreness (DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to determine the effects of both transcutaneous electrical nerve stimulation (TENS) and microcurrent electrical neuromuscular stimulation (MENS) on DOMS, Twenty-seven untrained and male volunteer subjects were randomly assigned to one of three treatment groups: 1) a group that received TENS (7 Hz), 2) MENS (60 ${\mu}A$, .3 pps) or 3) a control group that received no treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24 hours and 48 hours. Subjects attended on two consecutive days for treatment and measurement of elbow flexion, extension, resting angle (universal goniometer), and pain (visual analogue scale: VAS) on a daily basis. Measurements were taken after treatment. Analysis of results were as follows; 1) There were no significant differences between TENS and MENS by one-way repeated ANOVA, 2) The t-test for pain, resting, flexion and extension angle revealed significant differences within TENS group, 3) The t-test for resting angle revealed significant differences within MENS group.

  • PDF

The Comparison of Effect of MC Intensity in Pain and ROM in Delayed Onset Muscle Soreness (미세전류 자극 강도에 따른 지연성 근육통의 통증과 관절가동범위에 미치는 영향)

  • Kim, Seun-Deuck;Park, Hye-Mi;Jung, Hwa-Su
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose : We investigated the effects of microcurrent(MC) electrical stimulation on each intensity($100{\mu}A,\;200{\mu}A,\;500{\mu}A$ - 30pps frequency was same) on delayed onset muscle soreness(DOMS). Methods : Subjects were assigned randomly divided into three groups of eight for three different treatment protocoals($100{\mu}A,\;200{\mu}A,\;500{\mu}A$-experimental groups). Twenty-four healthy males and females subjects were participated in this study. All subjects performed eccentric exercise of elbow flexor(biceps brachii) until exhausted. The measured items of elbow flexor muscle strength were Nicholas Manual Muscle Taster(NMMT). The measured items of elbow joint range of motion ROM) were Goniometer. The measured items of elbow flexor muscle pain were visual analogue scale(VAS). Treatment were applied at 30 minute exercise after and again at 24 hours and at 48 hours and at 72 hours after. Measurements were taken after treatment. Analysis of Results using repeated measures analysis of variance(ANOVA) and post hoc tests were as follows: two-way ANOVA with repeated measurement for muscle strength, flexion ROM, extension ROM and VAS. Results : This results showed eccentric exercise casused DOMS, DOMS response to eccentric exercise were reduces by microcurrent therapy. DOMS was significant decreased at $100{\mu}A,\;200{\mu}A,\;500{\mu}A$. Muscle strength was significant difference at all intensity. Elbow flexion ROM was significant difference at all intensity but elbow extension ROM was insignificant difference at all intensity. VAS score was significant difference at $100{\mu}A$ and $500{\mu}A$ but insignificant difference at $200{\mu}A$. All experimental groups showed insignificant difference with all intensity MENS. Conclusion : These findings indicate that microcurrent therapy is had effect on recovery from exercise induced muscle damage. In our's suggestion, microcurrent therapy is particularly more appropriate therapeutic modality.

Effects of Pre-eccentric Exercise on Exercise Induced Muscle Damage (사전 원심성 운동이 운동 유발 근 손상에 미치는 효과)

  • Kim, Byoung-Ju;Lim, Young-Eun;Yoon, Se-Won;Park, Seung-Kyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: This study examined the effects of pre-eccentric exercise to the quadriceps for the prevention of delayed onset muscle soreness (DOMS) and recovery of muscular function, depending on the training intensities. Methods: Subjects were divided into one of three groups that control group, a low intensity eccentric exercise group (LIEE group) and a high intensity eccentric exercise group (HIEE group). Subjects who underwent pre-eccentric exercise undertook exercise at an intensity of 25% and 75% of maximal voluntary contractions, respectively. After undertaking pre-eccentric exercise for eight weeks, eccentric exercise was applied again to induce DOMS. Measurements were conducted to examine pain and muscular function changes before, immediately after, after the induction of DOMS, and at the first, third, fifth and seventh days after the induction of DOMS. Results: Subjects who underwent pre-eccentric exercise showed a significant difference from the control group for the changes in the visual analogue scale (VAS) pain threshold, pressure pain threshold and muscle thickness by isometric contraction from measuring DOMS, and in particular, pain threshold by isometric contraction had remarkable effect in the LIEE group of subjects. For the change of the root mean square values using mechanomyography (MMG) as the measurement of muscular function recovery, subjects who had undertaken pre-eccentric exercise group showed a significant difference as compared to the control group. Conclusion: Pre-eccentric exercise was very effective in preventing and recovering delayed onset muscle soreness and was helpful to prevent and recover from decreased muscular function. The difference based on the intensity of exercise was not great, but it was more effective in the low intensity eccentric exercise group of subjects. Therefore, it can be considered that pre-eccentric exercise has a high application value as a physical therapy intervention for prevention and rehabilitation of sports injuries.

  • PDF

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

The Comparison of Low Intensity Eccentric Exercise and Dynamic Stretching on Delayed Onset Muscle Soreness (저강도 원심성 운동과 동적 스트레칭이 지연성 근육통에 미치는 효과 비교)

  • Lee, Su-Young;Kim, Ji-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4676-4685
    • /
    • 2012
  • We investigated to compare the effects of a low intensity eccentric exercise and dynamic stretching on symptoms of delayed onset muscle soreness (DOMS). The eighteen women who had not participated in a regular exercise programme for the lower extremities in the previous five months were randomly assigned to one of three experimental groups: control group, a low intensity eccentric exercise group and dynamic stretching group. We measured the joint range of motion (ROM), maximal voluntary isometric exercise (MVIC), muscle soreness rating scale and ultrasound image measurement before eccentric exercise inducing DOMS, and 24, 48, and 72 hours after an eccentric exercise inducing DOMS. The exercise programme in a low intensity eccentric exercise group and dynamic stretching group were respectively performed 3 times a week for 4 weeks before eccentric exercise inducing DOMS. There was significantly different between the groups in muscle soreness rating scale and MVIC (p<.05). However, there was not significantly different between groups in ultrasound image measurement and ROM (p<.05). These results suggest that a low intensity eccentric exercise group and dynamic stretching group effectively reduced muscle soreness rating scale out of the symptoms of DOMS. A low intensity eccentric exercise group may be an effective improvement than dynamic stretching group in muscle soreness rating scale.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.