• Title/Summary/Keyword: delayed fracture

Search Result 232, Processing Time 0.026 seconds

Acute Shortening and Delayed Lengthening in Management of Lower Leg Amputation: A Case Report

  • Kang, Seung Hoon;Jung, Sung Won;Jin, Jin Woo;Kim, Dong Hee;Shin, Sung Jin;Jeong, Min;Eho, Yil Ju
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.65-68
    • /
    • 2016
  • Acute bone shortening and delayed lengthening by Ilizarov surgery have been used to treat a wide range of soft tissue injuries including open fracture, osteomyelitis of the tibia and lower leg amputation. It has advantages such as bone lengthening as well as minimizing the loss of damaged tissues via tissue expansion. Here, we report a case of 52-year-old male with satisfactory results through acute bone shortening, replantation, and gradual bone lengthening after complete amputation of the ankle with related literature reviews.

Estimation of the Characteristics of Delayed Failure and Long-term Strength of Granite by Brazilian Disc Test (압열인장시험을 이용한 화강암의 지연파괴특성 및 장기안정성 평가)

  • Jung, Yong-Bok;Cheon, Dae-Sung;Park, Eui-Seob;Park, Chan;Lee, Yun-Su;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.24 no.1
    • /
    • pp.67-80
    • /
    • 2014
  • Long-term stability and delayed failure of granite were evaluated through the laboratory test based on Wilkins method and Brazilian disc test (BDT) which yields tensile strength, mode I fracture toughness and subcritical crack growth parameters. Then, the long-term strength of granite was estimated by using analytical models and long-term stability of compressed air-energy storage (CAES) pilot cavern pressurized up to 5 ~ 6 MPa was evaluated using numerical code, FRACOD with the determined subcritical crack growth parameters. The results of test and analyses showed that the subcritical crack growth index, n was determined as 29.39 and the inner pressure of 5 ~ 6 MPa had an insignificant effect on the long-term stability of pilot cavern. It was also found that the measurement and analysis of acoustic emission events can describe the accumulation of damage due to subcritical crack growth quantitatively. That is, AE monitoring can provide the current status of rock under loading if we make an identical installation condition in the field with that of the laboratory test.

Delayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction

  • Ryu, Yong Ah;Park, Jae Beom;Kyung, Hyun Woo;Song, Seung Han;Kang, Nak Heon
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.1
    • /
    • pp.35-38
    • /
    • 2015
  • Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilateral orbital floor fractures. The initial symptom occurred with proptosis in the right side as well as vertical dystopia, which had started 4 days earlier, 8 months after surgery. Any trauma history after the surgery was not present. We performed an exploration and removal of hematoma with Medpor titanium meshed alloplastic implant. A case of delayed orbital hematoma following alloplastic implant insertion was identified. It occurred within the pseudocapsule of the implant. One week after surgery, overall symptoms improved successfully, and no complications were reported during the 11-month follow-up period. Although rare, orbital hemorrhage is a potential complication of alloplastic orbital floor implants, which may present many years after surgery. As in the case presented, delayed hematoma should be included in the differential diagnosis of late proptosis or orbital dystopia.

A Treatment Case of Delayed Aortic Injury: The Patient with Posterior Rib Fracture

  • Park, Hyun-Seok;Ryu, Se-Min;Cho, Seong-Joon;Park, Sung-Min;Lim, Sun-Hye
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.406-408
    • /
    • 2014
  • A 66-year-old male patient arrived at the emergency room with a crush injury to his chest. Multiple rib fractures, hemothorax on both sides, left scapular fracture, liver laceration, and retroperitoneal hematoma were found upon the radiologic examination. After closed thoracostomy, the patient had been initially admitted to the intensive care unit, but he was transferred to the general ward on the next day. On the 4th post-trauma day, the patient complained of severe pain and there was bloody drainage through the chest tube. This case is an exploration with the consideration of the possibility of major bleeding and the subsequent repair of the descending thoracic aorta. This case is regarded as a case in which the aorta wall was damaged as the sharp margin of the fractured ribs caused continuous irritation.

The Influence of the Changing of Cyclic Frequency on the Corrosion Fatigue Fracture Behavior of the Dual Phase Steel in 3% NaCl Solution (3% NaCl 수용액중에서 복합조직강의 부식피로 파괴거동에 미치는 주파수변화의 영향)

  • O, Se-Uk;Sin, Gyu-Dong;Kim, Ung-Jip
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.141-148
    • /
    • 1995
  • Fatigue tests were carried out by a rotary bending testing machine of cantilever type. M.E.F.(ferrite encapsulated islands of martensite) materials were made by a series of heat treatment from a low carbon steel(SM 20 C). The fatigue tests were conducted at stress levels of 302 MPa and with frequencies of 25Hz, 2.5 Hz and 0.5 Hz in 3% NaCl solution. The fatigue strength increased with frequency got higher. The microcracks and corrosion pits were generated at the boundary between the matrix and the 2nd phase. The cracks generated by the corrosion pits were coalesced with the pits around the notch and became the initial crack. The $N_i/N_f$ ratio increased as the frequency and stress level decreased. The interference phenomenon increased with stress level and frequency gots higher. The crack propagation rate was delayed as the stress level lowers and the frequency gets higher, however, the range of the stress intensity factor depended only on a stress level.

  • PDF

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

Interfacial Crack Propagation Under Various Mode-Mixes

  • Park, Byung-Sun;Chai, Young-Suck
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2002
  • Initiation and propagation of interfacial crack along bimaterial interface are considered in this study. A biaxial loading device for a single specimen is used for obtaining a wide range of mode-mixities. The specimen is an edge-cracked bimaterial strip of glass and epoxy; the biaxial loading device, being capable of controlling displacements in two perpendicular directions, is developed. A series of interfacial crack initiation and Propagation experiments are conducted using the biaxial loading device for various mixed modes. Normal crack opening displacement (NCOD) is measured near crack front by a crack opening interferometry and used for extracting fracture parameters. From mixed mode interfacial crack initiation experiments, large increase in toughness with shear components is observed. The behavior of interfacial crack propagation analyzed as a function of mode-mix shows that initial crack propagation is delayed with increase of mode-mixity, and its velocity is increased with positive mode-mixity but decreased with negative case. However, it is found that crack propagation is less accelerated with positive mode-mixity than the negative mode-mixity, which may be caused by contact and/or effects of friction between far field and near-tip Held along the interfacial crack.

A study on the cracking mechanism of the welded parts in steel structures for the use of low temperature and high pressure (저온, 고압력용 강재 구조물의 용접부균열 발생과 그 대책에 관한 연구)

  • 김영식;배차헌;구자영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.328-338
    • /
    • 1985
  • When the low temperature service steels are used as materials for welded structure, some problems-brittleness and weld cracking, etc.-occur in welded part due to the change of mechanical and metallurgical characteristics resulted from the thermal cycle during the welding procedure. In this study, the experiments were conducted to investigate the change of mechanical and metallurgical characteristics of the welded part for the low temperature and high pressure service steels. Moreover, the Static and Dynamic Implant Test Method was introduced to this study in order to find out the mechnism of weld cracking. In addition, the fracture toughnesses of welded bond were inspected under the various low temperature environments. Main results obtained are as follows; 1) The effect of the hydrogen on the fatigue characteristics of the weld bond can be estimated by the new self-contrived Dynamic Implant Test equipment. 2) The fine micro-structure and low hardness in the heat affected zone can be obtained by the small heat input multi-pass welding. 3) The susceptibility of the delayed cracking is largely affected by the condition of used electrode. 4) The transition temperature of the fracture surface in weld bond appears to be higher 20 .deg. C than that in base metal.

  • PDF

Revascularization of Popliteal Artery Injury in Trauma Around Knee Joint (슬관절주위 외상에 의한 슬와동맥 손상의 재혈관화)

  • Han, Soo-Hong;Shin, Dong-Eun;Dan, Jin-Myung;Kim, Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • Popliteal artery injury in blunt trauma of knee joint is not common but poses high rate of amputation due to anatomical characteristics or delayed diagnosis and treatment. The aim of the present study is to review the authors' experiences with this condition and identify factors contributing to disability. We reviewed 7 cases of popliteal artery injury in trauma around knee. Injury mechanism, type of vessel damage, associated injuries, mangled extremity severity scores (MESS), ischemic time and additional treatments were analyzed. Tibial fracture, distal femoral fracture and serious soft tissue defect were combined. Mean MESS was 9.9 point and mean time of revascularization was 7.1 hours. Transfemoral amputation was performed in 2 cases due to vascular insufficiency and devastating infection, and 4 patients were able to walk without any support at the last follow up. Age, the severity of soft tissue injury, ischemic time and MESS are thought to be related to prognosis, and young patients with short ischemic time show best results, but authors experienced one exceptional case. We have to consider multiple factors related to the prognosis in popliteal artery injury with fractures around knee, and careful decision is needed regarding to early amputation.

  • PDF

Ankle Arthrodesis Using an Anterior T Plate in treating the Charcot joint of Ankle in a diabetic patient - A Case Report - (당뇨환자의 불안정 족관절에 있어서의 전방 T자형 금속판을 이용한 족관절 고정술)

  • Hwang, Kuhn-Sung;Sung, Il-Hoon;Cho, Soo-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.1
    • /
    • pp.23-27
    • /
    • 2001
  • It has been known that the ankle arthrodesis is a common surgical procedure for treating the ankle arthrosis and deformity that do not respond to the non-operative treatment. To date, various surgical techniques for the ankle arthrodesis have been reported. Clinical and biomechanical trials have shown that the rigid internal fixation leads the increased rate of the union. The ankle arthrodesis may be complicated with the nonunion, delayed union, malunion, and infection. In cases of the Charcot joint of the ankle in diabetic patients, however, arthrodesis could reduce the disadvantage of the nonoperative treatment, such as the loss of the reduction, progressive collapse, multiple ulcerations and infection. The object of this case report is to report our experience of a successful ankle arthrodesis using an anterior T plate in treating the unstable ankle of a diabetic patient, associated with the ankle fracture and the neuropathy. The surgical approach of this technique is simple so that it would allow less soft tissue injury, and this procedure would be regarded as one alternative to provide the rigid internal fixation in the ankle arthrodesis.

  • PDF