• Title/Summary/Keyword: deionized water

Search Result 474, Processing Time 0.024 seconds

A Study on Thermal Performance of Micro Channel Water Block for Computer CPU Cooling (컴퓨터 CPU 냉각용 미세채널 워터블록의 열성능에 관한 연구)

  • Kwon, Oh-Kyung;Choi, Mi-Jin;Cha, Dong-An;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.776-783
    • /
    • 2008
  • The object of this paper is to study on the thermal performance of a micro channel water block for computer CPU cooling. The effects of liquid flow rate, micro channel width and height on the thermal performances of water block are investigated experimentally. The water block was fabricated Al and machined with a micro milling. The water block consisted of rectangular micro channels 0.5 to 0.9 mm width and 1.5 to 4.5 mm height. The experiments were conducted using deionized water, over a liquid flow rate ranging from 0.2 to 2.0 kg/min. The base temperature and thermal resistance decrease with increasing of liquid flow rate. The increase of a channel height is more effective on the thermal resistance than the decrease of a channel width. At the flow rate of 0.7 kg/min, input power of 100 W, the base temperature and thermal resistance of sample 6 is $33^{\circ}C$ and $0.13\;^{\circ}C/W$ respectively.

Simultaneous Preconcentration and Determination of Trace Elements in Water Samples by Coprecipitation-Flotation with Lanthanum Hydroxide $[La(OH)_3]$

  • 김영상;김기찬
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.7
    • /
    • pp.582-588
    • /
    • 1995
  • The preconcentration and determination of trace Cd(Ⅱ), Cu(Ⅱ), Pb(Ⅱ), Mn(Ⅱ) and Zn(Ⅱ) in water samples were studied by the precipitate flotation using La(OH)3 as a coprecipitant. The analytes were quantitatively coprecipitated by adding 3.0 mL of 0.1 M La(Ⅲ) solution in a 1,000 mL water sample and adjusting the pH to 9.5 with NaOH solution. After the addition of the 1:8 mixed surfactant solution of each 0.1% sodium oleate and sodium lauryl sulfate, the solution was stirred with a magnetic stirrer for 10 minutes. The precipitates were floated to the surface by bubbling with nitrogen gas and collected in a small sampling bottle. The precipitates were dissolved in nitric acid and then the solutions were diluted to 25.00 mL with a deionized water. The analytes were determined by flame atomic absorption spectrometry. This procedure was applied to the waste water analysis. This technique was simple, convenient and especially rapid for the analysis of a large volume of sample. And also, from the recoveries of better than 92% which were obtained from real samples, this method could be judged to be applicable to the preconcentration and quantitative determination of trace elements in water samples.

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Synthesis and Properties of Ni-CNT Nanocomposites Using Electrical Explosion of Wire in Different Conditions

  • Maithili Biswas; Jin-Chun Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.3
    • /
    • pp.138-143
    • /
    • 2024
  • Ni-CNT nanocomposites were synthesized via the electrical explosion of wire (EEW) in acetone and deionized (DI) water liquid conditions with different CNT compositions. The change in the shape and properties of the Ni-CNT nanopowders were determined based on the type of fluids and CNT compositions. In every case, the Ni nanopowder had a spherical shape and the CNT powder had a tube shape. However, the Ni-CNT nanopowders obtained in DI water exhibited irregular shapes due to the oxidation of Ni. Phase analysis also revealed the existence of nickel oxide when using DI water, as well as some unknown peaks with acetone, which may form due to the metastable phase of Ni. Magnetic properties were investigated using a Vibrating Sample Magnetometer (VSM) for all cases. Nanopowders prepared in DI water conditions had better magnetic properties than those in acetone, as evidenced by the simultaneous formation of super paramagnetic NiO peaks and ferromagnetic Ni peaks. The DI water (Ni:CNT = 1:0.3) sample revealed better magnetic results than the DI water (Ni-CNT = 1:0.5) because it had less CNT contents.

Assessment of the Sorption Characteristics of Cadmium onto Steel-making Slag in Simulated Sea Water Using Batch Experiment (모사해수 조건에서 회분식 실험을 이용한 제강슬래그의 카드뮴 흡착 특성 평가)

  • Kim, Eun-Hyup;Rhee, Sung-Su;Lee, Gwang-Hun;Kim, Yong-Woo;Park, Jun-Boum;Oh, Myoung-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.43-50
    • /
    • 2011
  • Steel-making slag was investigated as reactive material for removal of cadmium in coastal area. Batch experiments of the sorption isotherm experiment and kinetic sorption experiment were performed. Result of sorption isotherm was more adequately described by Langmuir model than Freundlich model and theoretical maximum capacity (${\beta}$) of cadmium onto steel-making slag was found. Results of kinetic sorption experiments were evaluated by pseudo second order model to investigate sorption characteristics of cadmium onto steel-making slag. Results showed that the equilibrium sorption amount of cadmium (q$q_e$) increased and the rate constant ($k_2$) and initial sorption rate (h) decreased as the initial cadmium concentration increased. The $q_e$ with simulated sea water was similar to that with deionized water and $k_2$ and h with simulated sea water was lower than those with deionized water. Results of kinetic experiments could be used to predict the result from sorption isotherm, since equilibrium sorption amounts calculated by pseudo second order model generally agreed with those measured from sorption isotherm. The reaction time for the target removal rate could be calculated by the pseudo second order model using kinetic sorption tests results.

Micro-PIV Measurements of In Vitro Blood Flow in a Micro-Channel

  • Park, Cheol-Woo;Lee, Sang-Joon;Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.2
    • /
    • pp.30-35
    • /
    • 2003
  • Flow characteristics of blood flow in a micro channel were investigated experimentally using a micro-PIV (Particle Image Velocimetry) velocity field measurement technique. The main objective of this study was to understand the real blood flow in micron-sized blood vessels. The Reynolds number based on the hydraulic diameter of micro-channel for deionized (DI) water was about Re=0.34. For each experimental condition, 100 instantaneous velocity fields were captured and ensemble-averaged to get the spatial distributions of mean velocity. In addition, the motion of RBC (Red Blood Cell) was visualized with a high-speed CCD camera. The captured flow images of nano-scale fluorescent tracer particles in DI water were clear and gave good velocity tracking-ability. However, there were substantial velocity variations in the central region of real blood flow in a micro-channel due to the presence of red blood cells.

  • PDF

Preparation of Polyynes by the Laser Ablation of Graphite in Water and Organic Solvents

  • Shin, Seung-Keun;Park, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.597-600
    • /
    • 2012
  • Polyynes were formed by laser ablation of a graphite target in deionized water ($H_2O$ and $D_2O$) and various organic solvents such as acetonitrile, n-hexane, and c-hexane and were identified by analyzing ultraviolet (UV) absorption and Raman spectra. We assigned the major UV absorption peaks that coincided with the electronic transitions corresponding to linear polyyne chains. The UV absorption peak intensities of a polyyne solution decreased as the holding temperature of the solution increased. Also, the absorption spectra of polyynes obtained by laser ablation of a graphite target at different volume fractions of $H_2O$ and $D_2O$ were examined.

Analysis on Cyclic Voltammograms at SrO${\cdot}6Fe_{2}O_{3}$ Electronic Ceramics Interfaces (SrO${\cdot}6Fe_{2}O_{3}$전자 Ceramics 계면에서 순환전압도 해석)

  • 천장호;조은철;라극환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.78-83
    • /
    • 1992
  • The current-voltage characteristics at SrO${\cdot}6Fe_{2}O_{3}$ electronic ceramics interfaces have been studied using cyclic voltammetric methods. The symmetrical and stable cyclic voltammograms, which indicate the same anodic and cathodic process, are obtained on the whole experiments. The approximate saturation current is 50$\mu$A but the value depends on the experimental processes of the electrode specimens. The current-voltage characteristics of SrO${\cdot}6Fe_{2}O_{3}$ electronic ceramics in dilute aqueous electrolytes or double deionized water are determined by the water adsorption process and the interconnected porosity effect. On the other hand, the current-voltage characteristics in relatively concentrate aqueous electrolytes are determined by the ionic adsorption process and the related electrical double layers. The SrO${\cdot}6Fe_{2}O_{3}$ electronic ceramics can be directly used as an electrochemically stabled resistor, electrode or a humidity sensor.

  • PDF

Preparation and rheological behavior of polystyrene/multi-walled carbon nanotube composites by latex technology

  • Woo, Dong-Kyun;Kim, Byung-Chul;Lee, Seong-Jae
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.3
    • /
    • pp.185-191
    • /
    • 2009
  • Polystyrene/multi-walled carbon nanotube (PS/MWCNT) composites were prepared by the use of latex technology. The monodisperse PS latex was synthesized by an emulsifier-free emulsion polymerization from styrene/potassium persulfate/water system in the presence of ethanol. The MWCNTs were first treated with acid mixture to eliminate impurities, dispersed in deionized water driven by ultrasonicator, and then mixed with the PS latex. From these mixtures, PS/MWCNT composites were prepared by freeze-drying and subsequent compression molding. In the small-amplitude oscillatory shear experiments, both complex viscosity and storage modulus increased with increasing MWCNT content. A pronounced effect of MWCNT content was observed, resulting in larger storage modulus and stronger yield behavior at low frequencies when compared to unmodified PS. It showed a transition from viscous to elastic behavior with increasing MWCNT content. Over the MWCNT content of 3 wt%, the storage modulus was higher than the loss modulus across all frequencies.

Power Dependence on Formation of Polyynes by Laser Ablation in Water

  • Park, Young Eun;Shin, Seung Keun;Park, Seung Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1039-1042
    • /
    • 2013
  • Polyynes were prepared by liquid laser ablation of a graphite target in deionized water at various physical conditions such as laser power (20 and 40 mJ/pulse) and ablation wavelengths (355, 532, and 1064 nm). The effects of physical parameters on the linear carbon chain length were examined by analyzing the densities of polyynes with different carbon numbers ($C_6H_2$, $C_8H_2$, and $C_{10}H_2$) as well as their branching ratios. We concluded the photophysical processes turned out to play a more significant role than thermal ones in the formation of polyynes.