• 제목/요약/키워드: dehumidification performance

검색결과 78건 처리시간 0.024초

시설원예 습도환경 제어를 위한 냉각식 제습기 개발 (Development of a Refrigeratory-Based Dehumidifier for Humidity Environment Control in Greenhouse)

  • 강금춘;연광석;유영선;김영중;강연구;백이
    • Journal of Biosystems Engineering
    • /
    • 제32권4호
    • /
    • pp.247-255
    • /
    • 2007
  • During the winter season in Korea, the relative humidity of greenhouse at night often exceeds 90% because air temperature inside the greenhouse is usually controlled using a heater with all of windows closed to minimize heat loss, thereby requiring the use of a dehumidifier that can maintain optimum humidity levels of $70{\sim}80%$ to provide a good growth condition of crops. Also, such a high humid condition can cause the development of a pest, such as insects, fungi or diseases. However, the use of most conventional dehumidifiers for low temperature dehumidification is limited because their performance is degraded due to frost accumulation on the evaporator coil. This study was carried out to develop a refrigeratory-based dehumidifier suitable for low temperature dehumidification in greenhouse cultivation. The developed dehumidifier consists of a condenser and an evaporator installed separately so that relative and absolute humidity levels can be reduced when air passed through the condenser and evaporator, respectively. The prototype dehumidifier showed a dehumidification capacity of $5{\sim}7kg/h$ when air with a temperature of $15{\sim}25^{\circ}C$ and a relative humidity of $70{\sim}95%$ came into the dehumidifier. Under the condition that either temperature or relative humidity was fixed, the amount of condensed water was proportional to the levels of both temperature and relative humidity.

저온에서 흡착제의 제습효과에 대한 연구 (A Study on the Dehumidification effect of Adsorbent at low Temperature)

  • 이민석;정윤호;임소민;허재우;김종열
    • 융합신호처리학회논문지
    • /
    • 제21권4호
    • /
    • pp.177-182
    • /
    • 2020
  • 친환경적이고 에너지 절약적인 난방 방법으로 히트펌프에 대한 관심이 높아지고 있다. 특히, 저온 지역에서 난방이 가능한 히트펌프를 개발하기 위해 실외기 표면에 서리가 발생하지 않도록 하는 연구가 많아지고 있다. 즉, 온도가 낮은 지역에서 히트펌프를 통해 난방을 할 경우 실외기 표면에 서리층이 형성되어 전열성능을 떨어뜨려 난방능력을 감소시키는 것이 일반적이다. 따라서 본 연구에서는 히트펌프의 실외기에 유입되는 습공기의 수증기를 흡착식 제습시스템을 부착하여 제거하고자 한다. 본 연구를 통해 저온지역에서 가장 효과적인 제습방법을 제시할 수 있을 것으로 판단된다. 그리고 히트펌프의 실외기 전면에 흡착식 제습시스템을 부착하여 에너지 효율이 높은 히트펌프를 개발할 수 있을 것으로 사료된다.

액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구 (Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer)

  • 최광환;윤정인;김보철
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구 (A Study on the Performance of Home Clothes Dryer using Thermoelectric Module)

  • 이민재;공상운;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

열회수 냉각 제습기의 이론적 해석 (Theoretical Analysis of a Recuperative Refrigeration Dehumidifier)

  • 김동선
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.48-54
    • /
    • 2014
  • A refrigeration dehumidifier with a recuperative heat exchanger is theoretically analyzed. The recuperative heat exchanger is located between the two air streams from and to the dehumidifying coil, and reduces the sensible heat load in dehumidification process. A simple model is developed to predict performance of the dehumidifier. The model predicts that the recuperative heat exchanger is effective especially in the low humidity condition, where the sensible heat load is relatively large. It is predicted that, by adopting a recuperative heat exchanger, a maximum 30~110% increase in COP is possible for indoor air at $27^{\circ}C$, and 40~60% relative humidity.

재생증발실 냉각기의 구조에 따른 최적설계 비교 (Comparison of Optimum Design due to the Structure of the Regenerative Evaporative Cooler)

  • 최봉수;홍희기;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.359-364
    • /
    • 2005
  • In dehumidification evaporation cooling system. the regeneratie evaporative cooler(REC) makes an important role to reduce the sensible cooling load in the system through evaporative cooling, By this reason, many studies about increasing the cooling capacity of the REC were undertook. In this paper, we analyzed the cooling characteristics of the REC due to the structures of the REC and determined the best structure for the REC's effectiveness and cooling capacity. From the study. we could obtain some important results: at first. corrugated type has the benefit to expand the channel width of the REC, But because the type has some weak points about the size and weight. there is almost no benefit to improve the performance of the REC. Through these reasons. we decided that finned type is the best structure to improve the performance of the REC.

  • PDF

히트펌프 건조기용 PF 열교환기 성능 및 해석 연구 (Study on Performance and Analysis of PF Heat Exchanger for Heat Pump Dryer)

  • 김기영;이석현;권영철;전종균;박삼진
    • 한국산학기술학회논문지
    • /
    • 제14권4호
    • /
    • pp.1576-1581
    • /
    • 2013
  • 본 연구에서는 히트펌프 건조기용에 적용될 PF 열교환기에 대하여 연구되었다. PF 열교환기의 설치 경사각($0^{\circ}$, $30^{\circ}$, $60^{\circ}$)에 따른 3종 PF 열교환기의 능력과 제습량을 측정하였다. 실험은 건구온도 $60^{\circ}C$, 상대습도 70%, 풍속 0.5m/s에서 진행되었다. 실험결과 경사각이 증가할수록 열교환기의 성능이 우수하였으며, PF3가 능력과 제습량에서 가장 우수하였다. 그러나 경사각이 $60^{\circ}$에서는 능력과 제습량이 크게 감소하였다. 실험값을 예측하기 위해 PF 열교환기의 능력과 제습량을 예측할 수 있는 계산프로그램을 개발하였다. PF 열교환기 3종에 대한 실험값과 계산값은 능력의 경우에 최대 2% 이내를 제습량의 경우에 최대 3% 이내에서 만족한 결과를 보여주었다.

고분 공조시스템의 운전특성 및 제습부하에 관한 연구 (A Study on the Performance and Dehumidification Load of an HVAC System for Conservation of Ancient Tombs)

  • 박진양;고석보;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.253-262
    • /
    • 2007
  • Although the importance of good conservation of historical sites including ancient royal tombs is well aware, still not much attention has been paid for facilities to realize it. There are numerous ancient royal tombs spread in Korean peninsula which are opened and some of them are selectively on display for public access. However, the conservation measures of these sites have not been seriously investigated. Even the level of understanding of the underground environment of tombs is not satisfactory. In the present study, we focus on the dehumidification loads to maintain appropriate conservation conditions in terms of temperature and humidity. Two experimental tombs different in size were built in KNU (Kongju National University) campus with the dimensions ($L{\times}W{\times}H$) of $1.0m{\times}2.8m{\times}1.0m\;and\;1.3m{\times}3.0m{\time}1.2m$, respectively, HVAC systems are installed to maintain a suitable condition for conservation, i.e., $22{\pm}2^{\circ}C$ in temperature and $55{\pm}5%$ in relative humidity. The condensed water are measured to estimate the dehumidification loads while the temperature and the humidity inside the tombs were maintained within the specified range.

시설원예용 제습기 개발 (Development of Dehumidifier for Protected Horticulture)

  • 연광석;강금춘;강연구;유영선;김영중;백이
    • Journal of Biosystems Engineering
    • /
    • 제30권2호
    • /
    • pp.110-113
    • /
    • 2005
  • Relative humidity of air In the greenhouse has to be maintained at 70 to 80 percents to provide a better growth condition of crops. To control relative humidity of air in the greenhouse, a dehumidifier functioning by refrigeration cycle was designed and manufactured in this study. And, results of its performance test in the greenhouse site were reported. The developed dehumidifier has separated condenser and evaporator in the heat exchanger part in order to increase dehumidifying capacity at a low temperature condition. When the conditions of incoming air into the dehumidifier were temperature of $15\~25^{\circ}C$ and relative humidity of $0\~95\%$, quantity of condensed water per hour, ie, dehumidification rate was $4.7\~7.0\;kg/hr$. Relative humidity difference was not greater than 5 percents at various locations in the greenhouse due to proper distributing of dehumidified air through vinyl duct. Thermal energy output from the developed dehumidifier was about 8,5000 kcal/hr that was 7 percents of maximum greenhouse heating load of 10 a.

리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어 (Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil)

  • 이상열;이충건;어승희;오광철;오재헌;김대현
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.337-341
    • /
    • 2014
  • 본 연구는 냉각코일과 리튬브로마이드 수용액을 활용하여 유리 chamber 내 냉각 및 제습 실험을 수행하였다. 냉각수 온도별 냉각 효과와 리튬브로마이드 수용액의 제습량을 확인하였으며, 이를 동시에 적용하여 실험을 수행하였다. 냉각수 온도별 냉각 실험은 279K, 286K, 293K에서 각각 19K, 13K, 10K 가량 감소되는 경향을 보였다. 냉각수 온도가 낮을수록 높은 냉각 성능을 보였으며, 여름철 상하수도 온도인 293K의 물로도 충분히 작물이 생육하기 좋은 온실 내부온도를 유지할 수 있다고 판단되었다. 또한 리튬브로마이드 수용액을 활용한 제습 실험에서는 약 80%의 외부 습도가 리튬브로마이드 수용액과 결합하여 약 50%로 감소되어 약 30%의 제습량을 보였으며, 이는 시설 내 제습 시스템의 적용에 적합한 물질로 판단된다. 냉각코일과 리튬브로마이드 수용액을 동시에 적용한 실험에서 약 9K의 온도 강하, 15%의 제습량을 나타냈으며, 리튬브로마이드 수용액이 수증기를 흡수하는 과정에서 반응열이 발생하는 것을 확인하였다. 또한, 시뮬레이션을 통해 냉각 실험 결과와 대비 비교한 결과 약 299.7K의 내부 온도를 보여 일치하는 것을 확인하였다. 수분의 제습과정을 거치면서 농도가 낮아진 리튬브로마이드 수용액(희용액)은 수집탱크로 모아 재생부로 이송되어 가열, 수분을 증발시켜 농용액으로 전환된 후 열교환을 거쳐 냉각되어 다시 제습시스템으로 공급되는 시스템을 적용하면 일정량의 리튬브로마이드 수용액만으로 온실 제습을 할 수 있을 것으로 판단된다. 본 실험을 통해 냉각 및 제습이 동시에 가능하다는 것을 확인하였으며, 리튬브로마이드 수용액을 활용하여 실제 온실에 적용된다면 기존 온실에서 사용하고 있는 냉방 및 제습 방법에 비해 에너지 절감을 통한 경제적 효과를 얻을 수 있을 것으로 판단된다. 향후, 제습 부분은 시뮬레이션을 통한 분석 및 실험결과와 대비 검증이 요구되고, Lab scale의 제습 시스템에서 Farm scale의 온실 규모로 확장하여, 추가 변수에 대한 제습 및 냉각 연구가 수행되어야 할 것이다.