• 제목/요약/키워드: degradation ratio

검색결과 1,156건 처리시간 0.012초

적응형 서비스를 제공하는 이동통신망에서의 서비스 품질 척도 추정 모델 (Quality of Service Parameters Estimation Model for Adaptive Bandwidth Service in Mobile Cellular Networks)

  • 정성환;홍정완;이창훈
    • 대한산업공학회지
    • /
    • 제33권1호
    • /
    • pp.153-163
    • /
    • 2007
  • An adaptive framework paradigm where the bandwidth values of the ongoing calls vary according to the trafficsituations is one of the promising concepts for overcoming poor resource conditions due to handoffs in mobilecellular networks. However, quantifying the level of bandwidth degradation of the ongoing calls in an adaptiveframework is important in view of Quality of Service (QoS) Provisioning. Therefore we introduce new QoSparameters, the Degradation Degree Ratio (DDR), which represents the average portion of the degradationdegree during degradation pehod of a call, and the Degradation Area Ratio (DAR), which represents the averageratio of a call's degradation level considering both the period and the degree of degradation jointly in multi-levelbandwidth service. We also develop a new analytical model for estimating the QoS measures such as theDegradation Pehod Ratio (DPR), DDR and DAR. We show how to calculate the QoS measures and illustrate themethod by numerical examples. The proposed model can be used to determine the optimal parameter of theCAC scheme and analyze the sensitivity ofthe QoS parameters in adaptive networks.

축력비 및 부재강성에 따른 강구조 대칭형 비가새 골조의 열화특성 (Degradation Characteristics of Symmetric Unbraced Steel Frames According to Variations of Member Stiffness and Axial ratio)

  • 이명재;김희동;임유하
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.327-335
    • /
    • 2011
  • 본 연구의 목적은 강구조 비가새 골조의 열화특성에 영향을 미치는 구조적 인자들을 해석적인 방법으로 평가하고 설계 초기 단계에서 열화 현상을 근사적으로 평가할 수 있는 방안을 제안하는데 있다. 해석적 연구를 위해 arc length method를 적용한 2차원 2차 수정 소성힌지 해석법을 적용하였으며, 단층 단스팬 골조와 다층 단스팬, 다층 다스팬 골조에 대해 해석을 수행하였다. 해석의 주요 변수로는 축력비와 기둥 보의 강성변화를 적용하였다. 연구 결과 무차원 열화강성은 부재의 강성과 축력비에 모두 영향을 받는 것으로 나타났으나, 축력비가 열화강성에 주는 영향이 더욱 큰 것으로 나타났다. 이를 바탕으로 축력비를 변수로 한 열화 강성 평가식을 제안하였다.

적응형 구조를 갖는 이동통신망에서 호 저하 시간 비율 추정 (Estimation of Degradation Period Ratio for Adaptive Framework in Mobile Cellular Networks)

  • 정성환;이세진;홍정완;이창훈
    • 대한산업공학회지
    • /
    • 제29권4호
    • /
    • pp.312-320
    • /
    • 2003
  • Recently there is a growing interest in mobile cellular network providing multimedia service. However, the link bandwidth of mobile cellular network is not sufficient enough to provide satisfactory services to users. To overcome this problem, an adaptive framework has been proposed. In this study, we propose a new method of estimating DPR(Degradation Period Ratio) in an adaptive multimedia network where the bandwidth of ongoing call can be dynamically adjusted during its lifetime. DPR is a QoS(Quality of Service) parameter which represents the ratio of allocated bandwidth below a pre-defined target to the whole service time of a call. We improve estimation method of DPR using DTMC(Discrete Time Markov Chain) model by calculate mean degradation period, degradation probability more precisely than in existing studies. Under Threshold CAC(Call Admission Control) algorithm, we present analytically how to guarantee QoS to users and illustrate the method by numerical examples. The proposed method is expected to be used as one of CAC schemes in guaranteeing predefined QoS level of DPR.

오일 열화 진행에 따른 오일의 색채 특성 변화 (Change in Chromatic Characteristics with the Oil Degradation)

  • 공호성;오씨아빅터;한흥구;류보브마르코바
    • Tribology and Lubricants
    • /
    • 제24권1호
    • /
    • pp.7-13
    • /
    • 2008
  • In this work, a simple and low cost sensor technique is proposed to test oil color in real time using in-line sensor. It is presented to use a ratio of intensity in red wavelength range to intensities of green and blue wavelength ranges (defined as a 'chromatic ratio') in order to estimate the oil color change. The proposed sensor technique is realized by irradiating a white LED as light source and a RGB color sensor as photoreceiver, and the chromatic ratio of various types of used oils are measured. The results show that chromatic ratio generally reflects chemical deterioration of oil, including oil oxidation and thermal degradation. It is concluded that the proposed sensor could be used for an effective oil monitoring technology.

Experimental study on shear damage and lateral stiffness of transfer column in SRC-RC hybrid structure

  • Wu, Kai;Zhai, Jiangpeng;Xue, Jianyang;Xu, Fangyuan;Zhao, Hongtie
    • Computers and Concrete
    • /
    • 제23권5호
    • /
    • pp.335-349
    • /
    • 2019
  • A low-cycle loading experiment of 16 transfer column specimens was conducted to study the influence of parameters, likes the extension length of shape steel, the ratio of shape steel, the axial compression ratio and the volumetric ratio of stirrups, on the shear distribution between steel and concrete, the concrete damage state and the degradation of lateral stiffness. Shear force of shape steel reacted at the core area of concrete section and led to tension effect which accelerated the damage of concrete. At the same time, the damage of concrete diminished its shear capacity and resulted in the shear enlargement of shape steel. The interplay between concrete damage and shear force of shape steel ultimately made for the failures of transfer columns. With the increase of extension length, the lateral stiffness first increases and then decreases, but the stiffness degradation gets faster; With the increase of steel ratio, the lateral stiffness remains the same, but the degradation gets faster; With the increase of the axial compression ratio, the lateral stiffness increases, and the degradation is more significant. Using more stirrups can effectively restrain the development of cracks and increase the lateral stiffness at the yielding point. Also, a formula for calculating the yielding lateral stiffness is obtained by a regression analysis of the test data.

Degradation Characteristics of Pr/Co/Cr/Er Co-doped Zinc Oxide Varistors by Impulse Current Stress

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권6호
    • /
    • pp.348-352
    • /
    • 2014
  • In light of the sure protection function, the most important factors of a varistor are the clamping voltage ratio and degradation characteristics. The degradation characteristics of Pr/Co/Cr/Er co-doped zinc oxide varistors were investigated by impulse currents (0.4~2.1 kA) stress for the specified content of $Er_2O_3$ (0.5 and 2.0 mol%). The varistor doped with 2.0 mol% $Er_2O_3$ exhibited the best clamp characteristics, with the clamp voltage ratio (K) in the range of K = 1.63~1.88 at the impulse currents of 5-50 A. However, the varistor doped with 0.5 mol% exhibited excellent electrical stability, with variation rates for the breakdown field, for the nonlinear coefficient, and for the leakage current density of -6.9%, -12.6%, and -14.3%, respectively, after application of an impulse current of 2.1 kA. In contrast, the varistor doped with 2.0 mol% was destroyed after application of an impulse current of 1.2 kA.

Pseudomonas aeruginosa F722부터 유래된 biosurfactant를 이용한 등.경유 혼합물의 생분해율 향상 (Biodegradation Enhancement of The Mixture of Kerosene and Diesel by using Biosurfactant from Pseudomonas aeruginosa F722)

  • 오경택;박귀환;강창민;;정선용
    • KSBB Journal
    • /
    • 제18권6호
    • /
    • pp.529-535
    • /
    • 2003
  • 본 연구에서는 등$.$경유 혼합물을 Pseudomonas aeruginosa F722를 이용하여 분해시킬 때 생분해율에 미치는 생물계면활성제, 화학계면활성제 및 공기 공급량의 영향을 조사하였다. 그 결과, 탄화수소 분해율은 0.01%와 0.15% 농도의 생물계면활제를 첨가하였을 때가 0.05%, 0.1% 및 0.2%농도의 생물계면활제를 첨가하였을 때보다 최고 6.2% 높은 94.3, 94.2% 제거율을 나타냈다. 하지만, 0.15% 생물계면활제를 첨가하였을 때가 0.01% 생물계면활제를 첨가하였을 때보다 탄화수소 분해율이 더 안정적이었다. 그리고 생물계면활성제 (surface tension; 30mN/m)와 화학계면활성제 (Tween 80;39mN/m, detergent;31mN/m)를 0.15% 농도로 첨가하여 배양하였을때, 탄화수소 분해율은 94.2, 93.5, 93.4%로 비슷하였다. 하지만, P. aeruginosa F722의 개체수는 생물계면활성제를 첨가했을 때가 화학계면활성제를 첨가했을 때보다 2배 이상 증가된 19 ${\times}$ $10^{7}$ cfu/$m\ell$로 조사되었다. 0.5vvm으로 공기를 공급하면서 교반을 수행하였을 때, 배양 3일 후, 사용균주를 접종하지 않은 공시험에서 탄화수소 분해율은 68.8%였으며, P. aeruginosa F722를 접종하였을 때는 94.8%이었다. 0.5 vvm으로 공기를 공급하였을 때가 공기를 공급하지 않았을 때보다 배양시간이 1/3로 단축되었다. 그리고 교반배양 (3일)과 정치배양 (10일)에서 탄화수소 분해율은 각각 94.8, 93.7%였다.

Seismic behavior of reinforced concrete T-shaped columns under compression-bending-shear and torsion

  • Ping, Chen Zong;Weiwei, Su;Yang, Yang
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.431-444
    • /
    • 2021
  • T-shaped column is usually used as side column in buildings, which is one of the weak members in structural system. This paper presented a quasi-static cyclic loading experiment of six specimens of reinforced concrete (RC) T-shaped columns under compression-flexure-shear-torsion combined loadings to investigate the effect in the ratio of torsion to moment (T/M) and axial compression ratio (n) and height-thickness ratio of flange plate (φ) on their seismic performance. Based on the test results, the failure characteristics, hysteretic curves, ductility, energy dissipation, stiffness degradation and strength degradation were analyzed. The results show that the failure characteristics of RC T-shaped columns mainly depend on the ratio of torsion to moment, which can be divided into bending failure, bending-torsion failure and shear-torsion failure. With the increase of T/M ratio, the torsion ductility coefficient increased, and in a suitable range, the torsion and horizontal displacement ductility coefficient of RC T-shaped columns could be effectively improved with the increase of axial compression ratio and the decrease of height-thickness ratio of flange plate. Besides, the energy dissipation capacity of the specimens mainly depended on the bending and shear energy dissipation capacity. On the other hand, the increase of axial compression ratio and the ratio of torsion to moment could accelerate the torsional and bending stiffness degradation of RC T-shaped columns. Moreover, the degradation coefficient of torsion strength was between 0.80 and 0.98, and that of bending strength was between 0.75 and 1.00.

연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석 (Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition)

  • 김경수;윤재호
    • Current Photovoltaic Research
    • /
    • 제6권3호
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

Influence of Hydrolytic Degradation on the Morphology of Cured Urea-Formaldehyde Resins of Different Formaldehyde/Urea Mole Ratios

  • Park, Byung-Dae;Jeong, Ho-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권2호
    • /
    • pp.179-186
    • /
    • 2011
  • In an effort to understand the hydrolytic degradation process of cured urea-formaldehyde (UF) resins responsible for the formaldehyde emission of wood-based composite panels, this study analyzed the influence of acid hydrolysis on the morphology of cured UF resins with different formaldehyde/urea (F/U) mole ratios such as 1.6, 1.4, 1.2 and 1.0. Field emission-scanning electron microscopy (FE-SEM) was employed to observe both exterior and fracture surfaces on thin films of cured UF resins before and after the etching with hydrochloric acid as a simulation of the hydrolytic degradation process. FE-SEM images showed that the exterior surface of cured UF resin with the F/U mole ratio of 1.0 had spherical structures after the acid hydrolysis while the other cured UF resins were not the case. However, the fracture surface observation showed that all the samples possessed spherical structures in the cured state of UF resins although their occurrence and size decreased as the F/U mole ratio increased. For the first time, we found the spherical structures in cured UF resins of higher F/U mole ratio of 1.4. After the acid hydrolysis, the spherical structures became a much predominant at the fracture surface. These results indicated that the spherical structures in cured UF resinswere much more resistant to the hydrolytic degradation by the acid than amorphous region.