• 제목/요약/키워드: deflection test

검색결과 847건 처리시간 0.026초

Modified p-y curves to characterize the lateral behavior of helical piles

  • Hyeong-Joo, Kim;James Vincent, Reyes;Peter Rey, Dinoy;Tae-Woong, Park;Hyeong-Soo, Kim;Jun-Young, Kim
    • Geomechanics and Engineering
    • /
    • 제31권5호
    • /
    • pp.505-518
    • /
    • 2022
  • This study introduces soil resistance multipliers at locations encompassed by the zone of influence of the helix plate to consider the added lateral resistance provided to the helical pile. The zone of influence of a helix plate is a function of its diameter and serves as a boundary condition for the modified soil resistance springs. The concept is based on implementing p-multipliers as a reduction factor for piles in group action. The application of modified p-y springs in the analysis of helical piles allows for better characterization and understanding of the lateral behavior of helical piles, which will help further the development of design methods. To execute the proposed method, a finite difference program, HPCap (Helical Pile Capacity), was developed by the authors using Matlab. The program computes the deflection, shear force, bending moment, and soil resistance of the helical pile and allows the user to freely input the value of the zone of influence and Ω (a coefficient that affects the value of the p-multiplier). Results from ten full-scale lateral load tests on helical piles embedded at depths of 3.0 m with varying shaft diameters, shaft thicknesses, and helix configurations were analyzed to determine the zone of influence and the magnitude of the p-multipliers. The analysis determined that the value of the p-multipliers is influenced by the ratio between the pile embedment length and the shaft diameter (Dp), the effective helix diameter (Dh-Dp), and the zone of influence. Furthermore, the zone of influence is recommended to be 1.75 times the helix diameter (Dh). Using the numerical analysis method presented in this study, the predicted deflections of the various helical pile cases showed good agreement with the observed field test results.

Experimental research on the behavior of circular SFRC columns reinforced longitudinally by GFRP rebars

  • Iman Saffarian;Gholam Reza Atefatdoost;Seyed Abbas Hosseini;Leila Shahryari
    • Computers and Concrete
    • /
    • 제31권6호
    • /
    • pp.513-525
    • /
    • 2023
  • This research presents the experimental and theoretical evaluations on circular steel-fiber-reinforced-concrete (SFRC) columns reinforced by glass-fiber-reinforced-polymer (GFRP) rebar under the axial compressive loading. Test programs were designed to investigate and compare the effect of different parameters on the structural behavior of columns by performing tests. Theses variables included conventional concrete (CC), fiber concrete (FC), steel/GFRP longitudinal rebars, and transversal rebars configurations. A total of 16 specimens were constructed and categorized into four groups in terms of different rebar-concrete configurations, including GFRP-rebar-reinforced-CC columns (GRCC), GFRP-rebar-reinforced-FC columns (GRFC), steel-rebar-reinforced-CC columns (SRCC) and steel-rebar- reinforced-FC columns (SRFC). Experimental observations displayed that failure modes and cracking patterns of four groups of columns were similar, especially in pre-peak branches of load-deflection curves. Although the average ultimate axial load of columns with longitudinal GFRP rebars was obtained by 17.9% less than the average ultimate axial load of columns with longitudinal steel rebars, the average axial ductility index (DI) of them was gained by 10.2% higher than their counterpart columns. Adding steel fibers (SFs) into concrete led to the increases of 7.7% and 6.7% of the axial peak load and the DI of columns than their counterpart columns with CC. The volumetric ratio had greater efficiency on peak loads and DIs of columns than the type of transversal reinforcement. A simple analytical equation was proposed to predict the axial compressive capacity of columns by considering the axial involvement of longitudinal GFRP rebars, volumetric ratio, and steel spiral/hoop rebar. There was a good correlation between test results and predictions of the proposed equation.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

Evaluation of Bending Creep Performance of Laminated Veneer Lumber (LVL) Formwork for the Design of Timber Concrete Composite (TCC) Structures

  • Hyun Bae KIM;Takuyuki YOSHIOKA;Kazuhiko FUJITA;Jun ITO;Haruka NOHARA;Keiji NOHARA;Toshiki NARITA;Wonwoo LEE;Arata HOSOKAWA;Tetsuiji TANAKA
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권4호
    • /
    • pp.375-382
    • /
    • 2024
  • The study focuses on evaluating the bending creep performance of laminated veneer lumber (LVL) formwork in timber concrete composite (TCC) structures. Timber-framed construction is highlighted for its environmental benefits and seismic resistance, but limitations such as poor tensile strength and brittle failure in bending hinder its use in high-rise buildings. Wood-concrete hybrid structures, particularly those using reinforced concrete slabs with TCC floors, emerge as a potential solution. The research aims to understand the time-dependent behavior of TCC components, considering factors like wood and concrete shrinkage and connection creep. The experiment was conducted in western Japan on the TCC floor designed for use in the Kama-city Inatsuki-higashi compulsory education school. The LVL formwork, measuring 9,000 mm by 900 mm, and concrete is loaded onto it for testing. The creep test periods are examined using concrete loading. It employs a comprehensive creep analysis, adhering to Japanese standards, involving deflection measurements and regression analysis to estimate the creep coefficient. Results indicate substantial deformation after shoring removal, suggesting potential reinforcement needs. The study recommends extending test periods for improved accuracy and recognizing regional climate impacts. Overall, the research provides valuable insights into the potential of LVL formwork in TCC structures, emphasizing safety considerations and paving the way for further experimentation under varied conditions to validate structural integrity.

부식 강재 복공판의 재사용성 평가에 관한 기초적 연구 (A Preliminary Study on the Reused Channel-Type Lining Board with Corrosion-Damage)

  • 김인태;김동우;최형석;정진환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권4호통권56호
    • /
    • pp.170-179
    • /
    • 2009
  • 복공판은 규격화된 강재를 조합하여 용접에 의해 일체화 시킨 것으로 주로 지하작업공간의 확보, 가설 차도 및 보도의 용도로 사용되며, 지하철, 지하상가 등의 건설을 위한 복개부와 가설교량의 상부구조 등에 적용된다. 이러한 복공판이 부식 손상된 경우에는 정량적인 잔존내하력 평가 없이 육안조사에 의한 판별 후 교체 또는 일정기간 사용 후 교체 등으로 그 기능을 유지하고 있다. 이에 본 연구에서는 부식된 복공판의 지속적 사용한계를 확인하고 경제적이고 효율적인 복공판 교체시기를 결정하기 위하여, 실제 지하철 현장에서 사용되고 있는 부식 손상된 복공판을 대상으로 각 구성 강재의 잔존두께를 측정하고, 휨 재하실험을 실시하였다. 그리고 수치해석을 수행하여 그 결과를 실험결과와 비교, 분석하였다. 그 결과 복공판 측, 하판의 두께 감소량과 잔존내하력과의 관계를 분석하여, 부식두께 감소량에 의한 복공판의 적절한 교체주기를 결정할 수 있는 지표를 제시하였다.

BIM 기반의 단면이 손상된 말뚝의 수평 거동 해석 모형 개발과 적용 (Development of BIM Based Analytical Model for Laterally Loaded Piles with Defects and Application)

  • 정영욱;안재윤;김현승;안재훈
    • 한국지반공학회논문집
    • /
    • 제40권4호
    • /
    • pp.179-188
    • /
    • 2024
  • 많은 시설물의 기초로 사용되고 있는 현장타설말뚝의 시공 건전성을 확인하기 위하여 비파괴 건전도 시험이 사용되고 있다. 그러나 비파괴 건전도 시험은 내부 결함의 유무로만 기초의 안전성을 파악하며 결함의 위치 및 규모는 고려하고 있지 않다. 따라서, 본 연구에서는 말뚝 기초 결함의 단면 특성을 추출하고 횡방향 지지력 및 단면력을 검토하는 BIM 연계 횡방향 지지력 해석 모델을 제안하고, 이를 이용하여 결함이 존재하는 현장타설말뚝 기초의 안전성을 평가하고자 한다. 해석 결과, 상부에 존재하는 결함이 말뚝머리 변위 변화에 많은 영향을 끼쳤으며 결함에 의한 발생 휨모멘트 변화보다는 단면 축소로 인한 PM 상관도의 크기 감소가 부재 파괴의 위험도를 더 증가시키는 것을 확인하였다. 이러한 제안 방법은 현장타설말뚝의 입체적인 안전성 평가에 도움이 될 것으로 판단된다.

크로스홀 형태의 동적 콘 관입기를 이용한 노반의 강성특성 평가 (Stiffness Characterization of Subgrade using Crosshole-Type Dynamic Cone Penetrometer)

  • 홍원택;최찬용;임유진;이종섭
    • 한국지반공학회논문집
    • /
    • 제34권2호
    • /
    • pp.55-63
    • /
    • 2018
  • 열차의 하중을 적절한 강성으로 지지하기 위하여 다짐시공된 노반의 효과적인 강성특성 평가 기법에 대한 연구가 요구된다. 본 연구에서는 상부노반에 대하여 크로스홀 형태의 동적 콘 관입기(CDCP)를 적용함으로써 심도에 따른 강성특성을 평가하고자 하였다. CDCP의 적용을 위하여 세 단면의 다짐시공 완료된 상부노반이 대상 현장으로 선택되었으며, 각각의 개소에 대하여 CDCP 관입실험 및 들밀도시험, 동평판재하시험(LFWD)이 수행되었다. CDCP 관입실험 결과, 심도에 따른 탄성파 발신시간 및 전단파 수신시간을 획득하였으며, 이를 이용하여 노반의 전단파속도 주상도를 획득하였다. 또한, 동일 개소에서 들밀도시험으로부터 획득한 노반의 밀도 및 전단파속도 주상도를 이용하여 심도에 따른 최대전단강성계수($G_{max}$)를 평가할 수 있었다. CDCP 관입실험 및 들밀도시험으로부터 평가된 최대전단강성계수와 LFWD시험으로부터 획득한 동탄성계수($E_{vd}$)를 상호비교한 결과 매우 우수한 선형관계를 보이므로, CDCP 관입실험으로부터 유효한 강성특성을 평가할 수 있을 것이라 판단되었다. 또한, CDCP 관입실험으로부터 도출되는 결과는 일정 심도에 대한 대표 강성특성이 아닌 심도에 따른 연속적인 강성특성 이므로 노반의 강성특성 평가에 효과적으로 이용될 수 있을 것이라 기대된다.

측방변형을 받는 수동군말뚝의 거동분석-모형토조실험- (Analysis of Passive Pile Groups Subjected to Lateral Soil Movements-A Study on the Model Test-)

  • 장서용;원진오;정상섬
    • 한국지반공학회논문집
    • /
    • 제15권6호
    • /
    • pp.239-249
    • /
    • 1999
  • 본 논문에서는 측방변형을 받는 수동 군말뚝의 거동특성을 연구하기 위해 말뚝의 휨강성, 말뚝중심간격, 상대밀도와 두부구속조건을 변화시킨 단독말뚝과 말뚝 중심간격이 말뚝직경(D)의 2.5, 5.0, 7.0배가 되는 1열 군말뚝에 대한 모형실험을 실시하였다. 실내모형실험은 주문진 표준사와 화강 풍화토에 근입된 수동말뚝에 직사각형 형태의 측방변위를 점진적으로 가하여 주문진 표준사에 대해 총 32회, 화강풍화토에 대해 총 16회의 실험을 실시하였다. 주문진 표준사에 대해서는 알루미늄과 PVC말뚝을, 화강풍화토에 대해서는 PVC 말뚝만을 사용하였다. 그 결과 수동말뚝에서 발생하는 최대 휨모멘트와 말뚝변위는 말뚝의 휨강성, 말뚝중심간격, 지반조건, 두부구속조건에 따라 크게 영향을 받는다는 것을 알 수 있었다. 1열 군말뚝은 두부 구속조건에 상관없이 말뚝중심간격 7.0D 이하에서 그룹효과가 나타났으며, 7.0D에서 거의 단독말뚝과 같은 거동을 보임을 알 수 있었다. 말뚝의 간격이 좁아짐에 따라 말뚝의 변위와 휨모멘트 모두 감소하였다. 아울러 말뚝의 휨강성이 클수록 휨모멘트는 증가하나 변위는 감소하고, 상대밀도가 클수록 휨모멘트와 변위는 커지는 경향을 보였다. 상대밀도에 대한 휨모멘트의 크기 변화는 고정단에 의한 실험보다 자유단에 의한 실험에서 더 크게 나타났다.

  • PDF

초고강도 섬유보강 콘크리트 50M 합성 박스거더의 유한요소해석 (Finite Element Analysis of Ultra High Performance Fiber Reinforced Concrete 50M Composite Box Girder)

  • 타샤;김도현;한상묵
    • 한국건설순환자원학회논문집
    • /
    • 제6권2호
    • /
    • pp.100-107
    • /
    • 2018
  • 초고강도 섬유보강 콘크리트 50M 합성 박스거더에 대한 재료적 비선형 및 기하학적 비선형 유한요소해석이 수행되었다. 인장과 압축구역에서 구성방정식을 실험에 근거하여 모델링하였다. 비선형 유한요소해석의 정확성은 UHPFRC 50M 합성거더의 실험 결과와 비교하여 검증하였다. 1.5% 체적대비 섬유혼입률, 135MPa 압축강도 및 18MPa 휨인장강도 특성을 가진 UHPFRC 50M 합성거더에 대한 휨실험이 수행되었다. 포스트텐션힘으로 결합된 UHPFRC 합성거더는 3개의 UHPFRC 분절 U거더와 고강도 철근콘크리트 슬래브로 구성되었다. Midas FEA를 사용하여 UHPFRC 거더 부분은 8개 절점을 가진 3차원 6면체 모델링을 하였고, 철근와 강연선은 2개 절점을 가진 선형 요소로 모델링하였다. Total strain crack 모델에 기반을 둔 압축 및 인장 다중 선형모델을 사용하여 구성방정식을 설정하였고 균열은 smeared crack model로 구성하였다. 철근과 강연선의 비선형성은 Von Mises 규준을 적용하였다. 비선형 정적해석은 Newton-Rhapson 기법의 수렴치를 사용한 점진적 반복기법을 사용하여 해를 수행하였다. 유한요소해석은 하중-변위관계, 중립축 변화관계 및 균열양상에 대하여 실험 결과와 수치 해석 결과를 비교하여 검증하였다. 하중-변위 관계는 실험 결과와 비교해볼 때 매우 정확한 결과를 보여주고 있다. 본 논문에서 수행한 비선형 유한요소해석법은 철근보강 포스트텐션닝 초고강도 섬유보강 합성 박스거더의 휨거동 해석에 만족한 결과를 보여주고 있다.

화재 피해를 입은 철근콘크리트 슬래브의 잔존 구조성능 평가기법 (Evaluation Techniques for Residual Structural Performance of a Reinforced Concrete slab under Fire Damage)

  • 최광호
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.588-594
    • /
    • 2020
  • 이 연구에서는 철근콘크리트 건축물의 슬래브에 대해 화재 후 잔존 구조성능을 상온 시 내구성 진단과는 다르게, 고온특성을 보다 정확히 평가하기 위하여 전기로를 이용 800 ℃까지의 가열실험을 수행하였고 가열 전 후의 잔존 구조성능을 반발경도법과 초음파속도법 등의 비파괴 검사와 아울러 진동실험으로 구한 고유진동수로 처짐계산에 사용되는 강성을 평가하는 기법을 제안하였다. 반발경도를 이용한 압축강도 평가에서는 두꺼운 두께와 물/시멘트비(W/C)가 큰 실험체의 잔존 압축강도가 크게 나타났다. 콘크리트를 투과하는 초음파속도로 상온 대비 고온수열 콘크리트의 균질도를 평가하였으며 W/C와 부재 두께의 차이는 초음파 속도법의 결과에 큰 차이가 없는 것으로 판단되었다. 화재 피해 슬래브의 처짐 증가에 영향을 미치는 강성을 평가하기 위한 기법으로, 진동실험에 의해 고유진동수를 측정하고 이를 강성과의 관계식에 대입하였으며, 이를 슬래브 실험체에 적용해 본 결과 매우 합리적인 평가기법이 될 수 있음을 보여주었다. 또한, 고온 수열 후 부재의 잔존강도를 평가하기 위해 가열중과 가열 후 가력실험을 수행한 결과 800 ℃ 내력은 상온의 부재 내력에 비해 22%의 감소를 나타내었다.