• Title/Summary/Keyword: defect type

Search Result 1,074, Processing Time 0.035 seconds

A Study on the Cobalt Electrodeposition of High Aspect Ratio Through-Silicon-Via (TSV) with Single Additive (단일 첨가제를 이용한 고종횡비 TSV의 코발트 전해증착에 관한 연구)

  • Kim, Yu-Jeong;Lee, Jin-Hyeon;Park, Gi-Mun;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.140-140
    • /
    • 2018
  • The 3D interconnect technologies have been appeared, as the density of Integrated Circuit (IC) devices increases. Through Silicon Via (TSV) process is an important technology in the 3D interconnect technologies. And the process is used to form a vertically electrical connection through silicon dies. This TSV process has some advantages that short length of interconnection, high interconnection density, low electrical resistance, and low power consumption. Because of these advantages, TSVs could improve the device performance higher. The fabrication process of TSV has several steps such as TSV etching, insulator deposition, seed layer deposition, metallization, planarization, and assembly. Among them, TSV metallization (i.e. TSV filling) was core process in the fabrication process of TSV because TSV metallization determines the performance and reliability of the TSV interconnect. TSVs were commonly filled with metals by using the simple electrochemical deposition method. However, since the aspect ratio of TSVs was become a higher, it was easy to occur voids and copper filling of TSVs became more difficult. Using some additives like an accelerator, suppressor and leveler for the void-free filling of TSVs, deposition rate of bottom could be fast whereas deposition of side walls could be inhibited. The suppressor was adsorbed surface of via easily because of its higher molecular weight than the accelerator. However, for high aspect ratio TSV fillers, the growth of the top of via can be accelerated because the suppressor is replaced by an accelerator. The substitution of the accelerator and the suppressor caused the side wall growth and defect generation. The suppressor was used as Single additive electrodeposition of TSV to overcome the constraints. At the electrochemical deposition of high aspect ratio of TSVs, the suppressor as single additive could effectively suppress the growth of the top surface and the void-free bottom-up filling became possible. Generally, copper was used to fill TSVs since its low resistivity could reduce the RC delay of the interconnection. However, because of the large Coefficients of Thermal Expansion (CTE) mismatch between silicon and copper, stress was induced to the silicon around the TSVs at the annealing process. The Keep Out Zone (KOZ), the stressed area in the silicon, could affect carrier mobility and could cause degradation of the device performance. Cobalt can be used as an alternative material because the CTE of cobalt was lower than that of copper. Therefore, using cobalt could reduce KOZ and improve device performance. In this study, high-aspect ratio TSVs were filled with cobalt using the electrochemical deposition. And the filling performance was enhanced by using the suppressor as single additive. Electrochemical analysis explains the effect of suppressor in the cobalt filling bath and the effect of filling behavior at condition such as current type was investigated.

  • PDF

EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE (임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구)

  • Kang, Sang-Gyu;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

MANAGEMENT OF DENTIGEROUS CYST AND ERUPTION GUIDANCE OF INVOLVED TEETH USING OBTURATOR (Obturator를 이용한 함치성 낭종의 처치 및 이환된 치아의 맹출 유도)

  • Im, Chul-Seung;Lim, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.669-676
    • /
    • 1999
  • The dentigerous cysts originate through alteration of the reduced enamel epithelium after amelogenesis is completed, with accumulation of fluid between the layers of the enamel epithelium, or between this epithelium and the tooth crown. Next to the radicular cyst, they are the second most common type of odontogenic cyst. They occur over a wide age range with a peak frequency in the 2nd to 3rd decade. A substantial majority involve the mandibular third molars, followed in order of frequency by the maxillary permanent canines, mandibular second premolars, and maxillary third molars. With regard to the treatment of these cysts, the marsupialization procedure with obturator is recommended during the age when the eruptive force of the teeth is still strong. It can be effective when preservation of the displaced teeth is desirable. We treated the dentigerous cyst by marsupialization with obturator and guided the eruption of involved teeth to normal position. And we got the results as follows : 1. Severely dislocated teeth associated with dentigerous cyst erupted into proper position. 2. The enamel hypoplasia and the root deformity were observed some cases. 3. The bone expansion and defect were healed without infection and recurrence.

  • PDF

Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure (SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Jeong, Gi-Woo;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.

Hybrid Detection Algorithm of Copy-Paste Image Forgery (Copy-Paste 영상 위조의 하이브리드 검출 알고리즘)

  • Choi, YongSoo;Atnafu, Ayalneh Dessalegn;Lee, DalHo
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.389-395
    • /
    • 2015
  • Digital image provides many conveniences at the internet environment recently. A great number of applications, like Digital Library, Stock Image, Personal Image and Important Information, require the use of digital image. However it has fatal defect which is easy to be modified because digital image is only electronic file. Numerous digital image forgeries have become a serious problem due to the sophistication and accessibility of image editing software. Copy-Move forgery is the simplest type of forgery that involves copying portion of an image and paste it on different location within the image. There are many approaches to detect Copy-Move forgery, but all of them have their own limitations. In this paper, visual and invisible feature based forgery detection techniques are tested and analyzed. The analysis shows that pros and cons of these two techniques compensate each other. Therefore, a hybrid of visual based and invisible feature based forgery detection that combine the merits of both techniques is proposed. The experimental results show that the proposed algorithm has enhanced performance compared to individual techniques. Moreover, it provides more information about the forgery, like identifying copy and duplicate regions.

An Effective Multimedia Data Transmission in Ad-Hoc Networks Based on Bluetooth (블루투스를 이용한 애드혹 네트워크에서의 효율적인 멀티미디어 데이터 전송)

  • Kim, Byoung-Kug;Hong, Sung-Hwa;Hur, Kyeong;Eom, Doo-Seop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3B
    • /
    • pp.112-122
    • /
    • 2008
  • Basing on Piconet, The Bluetooth System forms network and transmits data. There is one Master and maximum 7 Slave bluetooth devices in one piconet. A job scheduler performed by Master bluetooth device, gives the chance of data transmission to Slave bluetooth devices, which connected to Master, using polling method in piconet. The maximum data rate is 723.2 kb/s when it uses ACL link with DH5 packet type in a piconet which is constructed by two bluetooth devices. However, if there are one master and two slave devices in a piconet, then the maximum data rate is reduced to a half(361.6kb/s), because a master device has to support same data rate for all connected devices. And, there is the defect in scatternet when data transmission rate becomes low(Maximum rate: 302.2kb/s). This paper proposals the new ad-hoc network topology called "DoublePico"for overcome the low data transmission in scatternet which is constructed by piconets. The method of doublepico that represented in this paper makes high data transfer rate(Maximum rate: 457.57kb/s) in bluetooth ad-hoc networks.

THE EFFECT OF THE BIORESORBABLE COLLAGEN MEMBRANE ON THE REGENERATION OF BONE DEFECT BY USING THE MIXTURE OF AUTOGRAFT AND XENOGRAFT BONE

  • Lee Jung-Min;Kim Yung-Soo;Kim Chang-Whe;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.325-341
    • /
    • 2003
  • Statement of problem: In cases where bony defects were present, guided bone regenerations have been performed to aid the placement of implants. Nowadays, the accepted concept is to isolate bone from soft tissue by using barrier membranes to allow room for generation of new bone. Nonresorbable membranes have been used extensively since the 1980's. However, this material has exhibited major shortcomings. To overcome these faults, efforts were made to develop resorbable membranes. Guided bone regenerations utilizing resorbable membranes were tried by a number of clinicians. $Bio-Gide^{(R)}$ is such a bioresorbable collagen that is easy to use and has shown fine clinical results. Purpose: The aim of this study was to evaluate the histological results of guided bone regenerations performed using resorbable collagen membrane($Bio-Gide^{(R)}$) with autogenous bone, bovine drived xenograft and combination of the two. Surface morphology and chemical composition was analyzed to understand the physical and chemical characteristics of bioresorbable collagen membrane and their effects on guided bone regeneration. Material and methods: Bioresorbable collagen membrane ($Bio-Gide^{(R)}$), Xenograft Bone(Bio-Oss), Two healthy, adult mongrel dogs were used. Results : 1. Bioresorbable collagen membrane is pure collagen containing large amounts of Glysine, Alanine, Proline and Hydroxyproline. 2. Bioresorbable collagen membrane is a membrane with collagen fibers arranged more loosely and porously compared to the inner surface of canine mucosa: This allows for easier attachment by bone-forming cells. Blood can seep into these spaces between fibers and form clots that help stabilize the membrane. The result is improved healing. 3. Bioresorbable collagen membrane has a bilayered structure: The side to come in contact with soft tissue is smooth and compact. This prevents soft tissue penetration into bony defects. As the side in contact with bone is rough and porous, it serves as a stabilizing structure for bone regeneration by allowing attachment of bone-forming cells. 4. Regardless of whether a membrane had been used or not, the group with autogenous bone and $Bio-Oss^{(R)}$ filling showed the greatest amount of bone fill inside a hole, followed by the group with autogenous bone filling, the group with blood and the group with $Bio-Oss^{(R)}$ Filling in order. 5. When a membrane was inserted, regardless of the type of bone substitute used, a lesser amount of resorption occurred compared to when a membrane was not inserted. 6. The border between bone substitute and surrounding bone was the most indistinct with the group with autogenous bone filling, followed by the group with autogenous bone and $Bio-Oss^{(R)}$ filling, the group with blood, and the group with $Bio-Oss^{(R)}$ filling. 7. Three months after surgery, $Bio-Gide^{(R)}$ and $Bio-Oss^{(R)}$ were distinguishable. Conclusion: The best results were obtained with the group with autogenous bone and $Bio-Oss^{(R)}$ filling used in conjunction with a membrane.

Maxillofacial rehabilitation of hemi-maxillectomy patient using a closed hollow bulb obturator fabricated by one-step polymerization technique: a clinical report (상악골 부분절제술 시행 환자에서 one-step 중합 기술로 만든 hollow bulb 폐색장치를 이용한 악안면 수복 증례)

  • Sim, Jae-Hyuk;Kim, Min-Kyoo;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • The maxillary defects lead to anatomical and functional deformity of the maxillofacial region. As far as functions are concerned, such defects can produce difficulty in speech, mastication, and deglutition. Obturator prostheses play a very important role in functional recovery for post-maxillectomy patients. To achieve rigidity of the obturator, appropriate retention should be given, and the weight of the prosthesis be reduced. There are two types of hollow bulb obturator: open and closed. A closed type has many advantages. Nevertheless, some problems, including complexity of fabrication and water leakage into the bulb, have the closed hollow obturator not be widely used. The one-step polymerization technique described in this case overcomes the shortcomings by easily constructing a small hollow bulb with two thermoplastic resin sheets.

MAXILLARY FLOATING TEETH IN A CHIARI MALFORMATION PATIENT (Chiari malformation 환아에서 상악 구치부의 부유치)

  • Shin, Eun-Young;Choi, Byung-Jai;Lee, Jae-Ho;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.649-653
    • /
    • 2001
  • The Chiari malformation is a deformation within the central nervous system which the lower brain stem and the cerebellum migrate into the foramen magnum causing herniation. In 1891, Arnold Chiari classified such symptoms into 3 categories. This case report is of a 8-year-old female with the complaint of a slight facial swelling and pain on the upper right molar during tooth brushing since 10 days before. Clinical examination showed gingival pocket formation on distal of the upper right first molar with pain and mobility of the tooth. Radiographic examination showed generalized low bone density in the upper molar area, and especially no bone support above the upper right and left first molars were noted. With a temporary diagnosis of Early-onset periodontitis, consultations with medical doctors for the possibility of an underlying systemic disease were made during periodontal treatment. 3D CT was taken with after a final diagnosis of Chiari malformation. Generalized thinning and defect of the cranial bone was noted and the foramen magnum was slightly enlarged. The occipital and maxillary bone was low in density, and the alveolar bone of maxillary posterior teeth was especially almost non-existing causing the upper right and left first molar to be floating. For this, the patient went under consultation with the department of neurosurgery and is still under observation. Periodontitis in childreren is very rare. When symptoms of periodontitis appear in a child, due to the possibility of an underlying systemic disease such as leukemia, histiocytosis X, and hypophosphatasia, proper examinations should be carried out so that the primary factor the symptoms can be treated.

  • PDF

A Study of Be Levels in p-GaSb:Be/GaAs Epitaxial Layers (p-GaSb:Be/GaAs 에피층의 Be 준위에 관한 연구)

  • Noh, S.K.;Kim, J.O.;Lee, S.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.135-140
    • /
    • 2011
  • By investigating photoluminescence (PL) spectra (20 K) of undoped and Be-doped p-type GaSb/GaAs epilayers, the origin has been analyzed by the change due to doping density. We have observed that the PL peak shifts to higher energy and the full-width half-maximum (FWHM) decreases with increasing the doping density below ${\sim}10^{17}cm^{-3}$, contrasted to shift to low energy and increasing FWHM above the density of ${\sim}10^{17}cm^{-3}$. From the variation of the integrated PL intensities of three peaks dissolved by Gaussian fit, it has been analyzed that, as the density increases, the $Be[Be_{Ga}]$ acceptor level (0.794 eV) reduces, whereas the intrinsic defect of $A[Ga_{Sb}]$ (0.778 eV) enhances together with a new $Be^*$ level (0.787 eV) locating between A and Be. We have discussed that it is due to coexistence of the Be acceptor level (${\Delta}E=16meV$) and the complex level (${\Delta}E=23meV$), $Be^*[Ga_{Sb}-Be_{Ga}]$combined by Be and A, in Be-doped p-GaSb, and that the level density of $Be[Be_{Ga}]$ may be reduced above ${\sim}10^{17}cm^{-3}$.