• Title/Summary/Keyword: deep straight groove

Search Result 5, Processing Time 0.017 seconds

A Lubrication Performance Analysis of Deep Straight Groove Mechanical Face Seal (깊은 직선 홈 미케니컬 페이스 시일의 윤활 성능해석)

  • 이안성;김준호
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.311-320
    • /
    • 2003
  • In this study a general Galerkin FE formulation of the incompressible Reynolds equation is derived for lubrication analyses of noncontacting mechanical face seals. Then, the formulation is applied to analyze the flexibly mounted stator­type reactor coolant pump seals of local nuclear power plants, which have deep straight grooves or plane coning on their primary seal ring faces. Their various lubrication performances have been predicted. Results show that the analyzed deep straight groove seal should have a net coning of less than 0.6 to satisfy the leakage limit. And for the same amount of equilibrium opening force the plane coning seal requires to have a 3 times higher dimensionless coning than the deep straight groove seal.

Lubrication Performance Analysis of Deep Straight Groove Seal (깊은 직선 홈 시일의 윤활 성능해석)

  • Lee An Sung;Kim Jun Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.193-200
    • /
    • 2003
  • In this study a general Galerkin FE formulation of the incompressible Reynolds equation is derived for lubrication analyses of noncontacting mechanical face seals. Then, the formulation is applied to analyze the flexibly mounted stator-type reactor coolant pump seals of local nuclear power plants, which have deep straight grooves or plane coning on their primary seal ring faces. Their various lubrication performances have been predicted. Results show that the analyzed deep straight groove seal should have a net coning of less than $0.6\;{\mu}m$ to satisfy the leakage limit. And for the same amount of equilibrium opening force the plane coning seal requires to have a 3 times higher dimensionless coning than the deep straight groove seal.

  • PDF

Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor (중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석)

  • Kim, Jeong-Hun;Kim, Dong-Wook;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.

A Description with Scanning Election Microscopy on the Tick Ixodes persulcatus (Schulze, 1930) Male and Female Specimens (Ixodes persulcutus 진드기 자웅 성충에 대한 주사전자현징집적 관찰소견)

  • 강영배;장두환
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.2
    • /
    • pp.305-312
    • /
    • 1985
  • The surface fine structures of Ixodes persulcatus (Schulze, 1930) male and female specimens were observed by means of a scanning electron microscope. A brief review on the biology of the ticks and their disease relationships was also presented. 1. The sexual dimorphism of the specimen was marked; the male was quite smaller than the female. 2. The genital groove was well developed and deep, the anal groove was distinct and characteristically extending anteriorly around the anus. 3. The 4th article was much reduced and situated on the top of the 3rd article ventrally. The hypostome dentition was usually 3/3. 4. The bottom of the basis capitulum of the male specimen was strictly straight in shape. 5. This species was regarded as one of the most important vectors for infectious diseases of migrating birds.

  • PDF

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF