• 제목/요약/키워드: decoupling control

검색결과 261건 처리시간 0.029초

PI Control with the Smith Predictive Controller for a Variable Speed Refrigeration System

  • Hua, Li;Choi, Jeong-Pil;Jeong, Seok-Kwon;Yang, Joo-Ho;Kim, Dong-Gyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.129-136
    • /
    • 2007
  • In this paper, we suggest PI control with the Smith predictive controller to improve transient response of a variable speed refrigeration system (VSRS). As the refrigeration system has long dead time inherently, it is difficult to get fast responses of super-heat and reference temperature. We incorporated the Smith predictive controller into PI to compensate the effect of the long dead time of the system. At first, we introduced the decoupling model of the system to control capacity and superheat simultaneously and independently. Next, we designed the predictive controller of the superheat based on PI control law. Finally, the control performance by the proposed method was investigated through some numerical simulations and experiments. The results of the simulations and experiments showed that the proposed PI control with the predictive controller could obtain acceptable transient behaviour for the system.

전기철도용 축소형 전력품질 보상설비에 대한 모델링 및 시뮬레이션 (A modeling and simulation for a Small-Scaled Power Quality Compensating Equipment of Electrical Railway)

  • 강문호;김주락;한문섭
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.96-102
    • /
    • 2007
  • This paper presents a study on the control of a power quality compensating equipment of electrical railway built in small-scaled to preliminary research. Because this compensating equipment is very complicated power electronics system, consisting of a scott transformer as a power source, four single phase inverters interconnected with DC-link capacitors and various electrical apparatuses, multiple controllers and control algorithms with high performance and reliability are needed. The major function of the compensating equipment is to manage reactive and active powers by using the four single phase inverters, so, the main control effort is focused on the power flow control which realized through the decoupling current control of the four inverters. Overall control system is designed with object oriented and analyzed on a Simulink window. The simulation results show that the design scheme is very effective for a complicated control system and the proposed controller has good performance.

아크센서를 적용한 격자형 용접용 모빌 로봇의 제어 (Motion Control of Mobile Robot with Arc Sensor for Lattice Type Welding)

  • 전양배;한영대;김상봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.319-324
    • /
    • 2001
  • This paper presents the motion control of a mobile robot with arc sensor for lattice type welding. Its dynamic equation and motion control method for welding speed and seam tracking are described. The motion control is realized in the view of keeping constant welding speed and precise target line even though the robot is driven along a straight line or corner. The mobile robot is modeled based on Lagrange equation under nonholonomic constraints and the model is represented in state space form. The motion control of the mobile robot is separated into three driving motions of straight locomotion, turning locomotion and torch slider controls. For the torch slider control, the proportional integral derivative (PID) control method is used. For the straight locomotion, a concept of decoupling method between input and output is adopted and for the turning locomotion, the turning speed is controlled according to the angular velocity value at each point of the comer with range of $90^{\circ}$ constrained to the welding speed. The experiment has been done to verify the effectiveness of the proposed controllers. These results are shown to fit well by the simulation results.

  • PDF

동적 고성능과 최대 전력 효율을 위한 유도 전동기 회전자 속도와 회전자 자속의 선형 비간섭 제어 (LINBAR DECOUPLING CONTROL OF ROTOR SPEED AND ROTOR FLUX IN INDUCTION MOTOR FOR HIGH DYNAMIC PERFORMANCE AND MAXIMAL POWER BFFICLENCY)

  • 김동일;하인중;고명삼;박재화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.48-53
    • /
    • 1989
  • We attempt to achieve both high dynamic performance and maximal power efficiency by means of linear decoupling of rotor speed (or motor torque) and rotor flux. The induction motor with our controller possesses the input-output dynamic characteristics of a linear system such that the rotor speed (or motor torque) and the rotor flux are decoupled. The rotor speed (or motor torque) responses are not affected by abrupt changes in the rotor flux and vice versa. The rotor flux need not be measured but is estimated by the well-known flux simulator. The effect of large variation in the rotor resistance on the control performances is minimized by employing a parameter adaptation method. To illuminate the significance of our work. we present simulation and experimental results as well as mathematical performance analyses.

  • PDF

DECOUPLING CONTROL OF AN INDUCTION MOTOR WITH RECURSIVE ADAPTATION OF ROTOR RESISTANCE

  • Kim, Gyu-Sik;Kim, Jae-Yoon;Yim, Chung-Hyuk;Kim, Joohn-Sheok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.23-28
    • /
    • 1998
  • We propose a nonlinear feedback controller that can control the induction motors with high dynamic performance by means of decoupling of motor speed and rotor flux. The nonlinear feedback controller needs the information on some motor parameters. Among them, rotor resistance varies greatly with machine temperature. A new recursive adaptation algorithm for rotor resistance which can be applied to our nonlinear feedback controller is also presented in this paper. The recursive adaptation algorithm makes the estimated value of rotor resistance track its real value. Some simulation results show that the adaptation algorithm for rotor resistance is robust against the variation of stator resistance and mutual inductance. In addition, it is computationally simple and has small estimation errors. To demonstrate the practical significance of our results, we present some experimental results.

  • PDF

(재귀)궤환형 회전자 저항 추정기를 갖는 유도전동기의 비간섭제어 (Decoupling Control of an Induction Motor with Recursive Adaptation of Rotor Resistance)

  • 김규식
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.99-103
    • /
    • 1998
  • 본 논문에서는 속도와 회전자 자속을 비간섭시킴으로써 전기설비등에 많이 적용되는 유도전동기를 고성능으로 제어할 수 있는 비선형 제어기를 제안한다. 이 비선형 제어기는 전동기 매개변수들에 대한 정보릎 필요 로한다 그중에 회전자 저항은 전동기 온도에 따라 크게 변한다. 또한, 이 비선형 제어기에 적용할 수 있는 새로운 (재귀)궤환형 회전자 저항 추정 알고리즘을 제안하고 본 알고리즘의 실용성을 입증하기 위하여 실험결과를 제시한다.

  • PDF

다변수 발전설비 모델에 대한 비간섭 제어기법 적용 연구 (Application of decoupling control method to the multivariable generating system)

  • 홍석교;김동화
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권2호
    • /
    • pp.43-50
    • /
    • 1992
  • 본 논문에서는 상태궤환에 의한 다변수 시스템의 비간섭 제어기법을 2입력2출력 터어보 발전기 시스템에 적용하는 문제를 연구하였다. 시뮬레이션 결과 터어보 발전기 시스템은 정준형으로 비간섭 될 수 있었고 궤한이득에 의해 임의로 극 배치함으로써 시스템이 주파수 또는 부하변화에 관계없이 비간섭 되고 안정한 제어가 될 수 있음을 보였다.

  • PDF

Energy Model Based Direct Torque Control of Induction Motor Using IP Controllers

  • Mannan, Mohammad Abdul;Murata, Toshiaki;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.405-411
    • /
    • 2012
  • This paper deals with direct torque control of an induction motor (IM) with constant switching frequency. The desired torque is obtained from the speed controller which is designed using the IP controller. Decoupling control of torque and flux is developed based on the energy model of IM using the IP controller strategies. The desired d-axis and q-axis stator voltage components are obtained from the designed controller, which decouples torque and flux. The constant switching frequency can be applied using space-vector pulse width modulation, since the desired stator voltage can be known from the decoupling torque and flux controllers. In order to achieve stable operation of the proposed IP controllers, the gains of the controllers are chosen by setting the poles in negative (left) half of s-plane and by choosing the rising time for the response of the step function. The proposed controller was verified in simulations using Matlab/Simulink and results have proven excellent performance. It was found that the proposed IP controllers can provide excellent performance to track the desired torque and speed and to reject the disturbance of load.

DC 마이크로 그리드를 위한 Three-port Dual Active Bridge DC-DC 컨버터의 독립 전력 제어 (Decoupled Power Control of Three-port Dual Active Bridge DC-DC Converter for DC Microgrid Systems)

  • 심주영;이준영;최현준;김학선;정지훈
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.366-372
    • /
    • 2018
  • Three-port dual-active bridge (DAB) converter in a DC microgrid was studied due to its high power density and cost-effectiveness. The other advantages of DAB include galvanic isolation and bidirectional power conversion capability using simple control modulation. The three-port DAB converter consists of a three winding transformer and three bridges. The transformer has three phases, which means that the ports are coupled. Thus, the three-port DAB converter causes unwanted power flows when the load connected to each port changes. The basic operational principles of the three-port DAB converter are presented in this study. The decoupling control strategy of the independent port power transfer is presented with a mathematical power model to overcome the unexpected power flow problem. The validity of the proposed analysis and control strategy is verified with PSIM simulation and experiments using a 1-kW prototype power converter.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.