• 제목/요약/키워드: decoupling control

검색결과 261건 처리시간 0.025초

Optimal Wiener-Hopf Decoupling Controller Formula for State-space Algorithms

  • Park, Ki-Heon;Kim, Jin-Geol
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권4호
    • /
    • pp.471-478
    • /
    • 2007
  • In this paper, an optimal Wiener-Hopf decoupling controller formula is obtained which is expressed in terms of rational matrices, thereby readily allowing the use of state-space algorithms. To this end, the characterization formula for the class of all realizable decoupling controller is formulated in terms of rational functions. The class of all stabilizing and decoupling controllers is parametrized via the free diagonal matrices and the optimal decoupling controller is determined from these free matrices.

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

가변속 냉동시스템의 비간섭제어를 위한 실험적 모델 (An Empirical Model for Decoupling Control of a Variable Speed Refrigeration System)

  • ;정석권
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.81-87
    • /
    • 2006
  • This paper deals with an empirical model for decoupling control to control the refrigeration system effectively. The conventional control schemes of the system are mainly focused on representative two control methods, superheat control and capacity control. The capacity control is basically conducted to respond partial loading conditions on the purpose of energy saving. The superheat control is mainly carried out to maintain maximum coefficient of performance (COP). In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. The capacity and superheat can not be controlled independently because of interfering loop when the compressor speed and opening angle electronic expansion valve is varied. Therefore, we suggest decoupling model to eliminate the interfering loop at first. Next, each transfer function in decoupling control model is obtained from number of experiments.

  • PDF

Adaptive Decoupling for IPM Machine(ICCAS 2005)

  • Cho, Sung-Uk;Park, Seung-Kyu;Ahn, Ho-Kyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1617-1620
    • /
    • 2005
  • The current control for interior permanent magnet machines is more complicate than surface permanent magnet machine because of its torque characteristic depending on the reluctance. For high performance torque control, it requires state decoupling between the d-current and q-current dynamics. However the variation of the inductances, which couples the state dynamics of the currents, makes the state decoupling difficult. So some decoupling methods have developed to cope this variations and each current can be regulated independently. This paper presents a novel approach for fully decoupling the states cross-coupling using parameter adaptation. The adaptation method is based on the error between reference currents and the currents with state decoupling which have to follow the references. This method is more object-oriented than the other online parameter estimation methods in IPM machine and other electrical machines

  • PDF

CPP를 갖는 선박 추진 시스템의 강인한 Decoupling 제어 (Robust Decoupling Control of Ship Propulsion System with CPP)

  • 김영복;변정환
    • 한국정밀공학회지
    • /
    • 제15권9호
    • /
    • pp.33-42
    • /
    • 1998
  • If a ship diesel engine is operated by consolidated control with Controllable Pitch Propeller(CPP), the minimum fuel consumption is achieved together with the demanded ship speed. For this, it is necessary that the ship is operated on the ideal operating line which satisfies the minimum fuel consumption and that the pitch angle of CPP and throtle valve angle are controlled simultaneously. In this point of view, this paper presents a controller design method for a ship propulsion system with CPP based on the decoupling control theory. To do this, Linear Matrix Inequality(LMI) approach is introduced for the control system to satisfy the given $H_\infty$ control performance and robust stability in the presence of physical parameter perturbations. The validity and applicability of this approach are illustrated by simulation in the all operating ranges.

  • PDF

개선된 비간섭 전류제어기를 이용한 영구자석 동기 전동기의 성능 향상에 관한 연구 (A study on Performance Improvement of SPMSM with Improved Decoupling Current Controller)

  • 조수억;김정수;김철우
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.151-159
    • /
    • 2007
  • 본 논문에서는 영구자석 동기전동기의 운전중 간섭성분을 형성하는 고정자 인덕턴스가 변화할 경우 d축 전류의 오차로부터 고정자 인덕턴스의 변화량을 보상할 수 있는 보상기를 제안하였다. 그리고 이러한 보상기를 기존의 DDC(Dynamic Decoupling Control)에 적용하여, 고정자 인덕턴스의 변화에 대한 강인성이 향상된 비 간섭 전류제어기를 설계하였다.

입력과 출력간의 비간섭 제어계 설계에 관한 연구 (A Study on a Sufficient Condition for Decoupling Control System Design)

  • 김영복
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.84-88
    • /
    • 1999
  • In this paper, systems described by state-space models are considered. For these systems, author studies the decoupling of linear systems and gives a sufficient condition for a system to be made feedback decouplable. Especially, the condition is given by LMI(Linear Matrix Inequality) form. Based on this condition, it is guaranteed that the system decoupling problem is achieved and the $H_{\infty}$ constraint is satisfied simultaneously. This result can be easily extended to the robust decoupling control system design problems.

  • PDF

Decoupling Control Design for Variable Speed Refrigeration System of a Ship

  • Hua, Li;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권7호
    • /
    • pp.808-815
    • /
    • 2006
  • In this paper, we suggest decoupling control method based on general PI control law to control variable speed refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering loop between capacity and superheat at first. Next, we design PI controller to control capacity and superheat independently and simultaneously. Finally the control performance was investigated through some experiments. The experimental results show that the PI control design can obtain good control performance under the adjustable control reference and thermal load variation.

냉연시스뎀의 비간섭화 기법에 관한 연구 (A Study on Decoupling Methods in Cold Rolling Mill)

  • 이관호;심재훈;권욱현;최승갑;박철재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.220-220
    • /
    • 2000
  • In this paper, some non-interaction problems in tandem cold rolling mill are considered, which are required to control effectively a thickness of the cold .oiled strip. First, Interstand non-interactive compensate. (Interstand NIC) is designed for decoupling the interaction between stands. Next, a L2 optimization based pre-compensator is designed for decoupling the interaction between roll gap and strip tension in the stand. Finally, the effectness of the proposed decoupling methods is demonstrated via simulations.

  • PDF