• 제목/요약/키워드: dead

검색결과 3,309건 처리시간 0.026초

Revolution of Dead-Cell: Production of New Generation by Intracytoplasmic Dried-Sperm Injection in Mammal

  • Kim, Duk-Im;Kim, Chang Jin;Lee, Kyung-Bon
    • Reproductive and Developmental Biology
    • /
    • 제39권3호
    • /
    • pp.69-76
    • /
    • 2015
  • In a conventional sense, dried-spermatozoa are all dead and motionless due to the lost of their natural ability to penetrate oocytes both in vivo and in vitro. However, their nuclei are completely able to contribute to normal embryonic development even after long-term preservation in a dried state when the dried-spermatozoa are microinjected into the oocytes. In this sense, dried spermatozoa must still be alive. Thus, defining spermatozoa as alive or dead seems rather arbitrary. Several drying method of sperm including freeze-drying, evaporative/convective-drying and heat-drying were represented in this review. Although the drying protocol reported here will need further improvement, the results suggest that it may be possible to store the male genetic resources.

SI 엔진 피스톤-링의 마찰모드 (The Frictional Modes of Piston Rings for an SI Engine)

  • 조성우;최상민;배충식
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.114-120
    • /
    • 2000
  • Friction forces of piston rings for a typical SI engine were independently measured while excluding the effects of cylinder pressure, oil starvation and piston secondary motion using a floating liner system. Friction patterns, represented by the measured friction forces, were classified into five frictional modes with regard to the combination of predominant lubrication regimes(boundary, mixed and hydrodynamic lubrication) and stroke regions(mid-stroke and dead centers). The modes were identified on the Stribeck diagram of the dimensionless bearing parameter and friction coefficients which were evaluated at the mid-stroke and at the dead centers. And the frictional modes were estimated to the full operation range. The compression rings behave in the mode where hydrodynamic lubrication is dominant at the mid-stroke and mixed lubrication is dominant at the dead centers under steady operating conditions. However, the oil control ring behave in the mode where mixed lubrication is dominant throughout the entire stroke.

  • PDF

지연요소를 수반하는 일차계통의 패러미터 추정에 관한 연구 (A Study of Parameter Estimation for First Order System with Dead Time)

  • 하주식
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.15-23
    • /
    • 1969
  • A lot of recent researches have shown that a Pseudo Random Binary Signal is a quite effective test signal to measure the impulse response of a plant. Generally speaking, however, such a response itself is not satisfactory to determine the appropriate control parameters or control inputs. Here, the author intends to estimate the unknown parameters of the First Order Plant with Dead Time by means of correlation method using M-sequence signal. The time constant T and the dead time L of the plant are eatimated with one tracking loop by automatically adjusting delay time .tau. of M-sequence signal according to variations of T and L. In this paper, a three level M-sequence signal is used as a test signal in order to avoid troublesome operations to calculate partial derivatives of a given performance index with respect to the parameters which are usually required in the Model Method. Several experiments with analogue computer using low pass filters as averaging circuits showed good results as expected.

  • PDF

전기철도 절연구분장치의 효율적 운용에 관한 연구 (A Study on Efficient Operation of Dead Section in Electric Railway)

  • 박정균;최현영;류형선;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.416-418
    • /
    • 2001
  • In the feeding system of electric railways it is necessary to divide the power lines for either ac or dc system. At this dead section, the system is damaged by the abrupt change of the coming-in power. This paper present the relationships. Between the feeding system and the trail-cars, and the counter plans to reduce the electrical arc and the breakdown at the dead section.

  • PDF

스위칭 손실저감을 위한 인버터 휴지기간 최소화 알고리즘 (A Noble Dead Time Minimization Algorithm for Reducing the Swtiching Losses)

  • 최정수;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1902-1904
    • /
    • 1998
  • In this paper. a noble dead time minimization algorithm is presented for reducing the switching losses. Firstly, the effects of the inverter dead time are examined, Secondly the principle of the proposed algorithm is explained with the commutation conditions. And the validity of the proposed algorithm is verified by simulation results. We can conclude from the results that the proposed algorithm have a virtue which is able to reducing the hamonics in the output voltages and which make the output voltage equal to the reference vlaue. Another merit is this method can reduce the number of inverter switchings.

  • PDF

가변속냉동시스템의 효율적인 과열도제어를 위한 예측제어기 설계 (Design of Predictive Controller for Effective Superheat Control of Variable Speed Refrigeration System)

  • 최정필;;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.9-15
    • /
    • 2008
  • In this paper, we suggest PI control with a predictive controller to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. The refrigeration system has long dead time in superheat inherently. The dead time makes the system difficult to achieve the satisfactory quick control response, especially superheat control response. In order to solve this problem, we designed a predictive controller based on PI control to progress superheat control performance. The control performance was investigated through some experiments to verify the effectiveness of the predictive controller.

  • PDF

시공 공정에 따른 건축 구조물의 구조해석 및 수직부재의 부등변형 (Structural Analysis for Building Structures reflecting Differential Column Shortening based upon Construction Sequence)

  • 조상규;이형우;최창식
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.333-341
    • /
    • 1998
  • The general method of structural analysis for building structures has been based upon the assumption that all dead loads are imposed on a building simultaneously throughout the entire structure. In reality, buildings are built floor by floor or a few floors at a time. The construction dead load is applied gradually onto the structure as the structure is being erected. The prevailing commercial software for structural analysis used to date have resulted in the representation of inaccurate structural behaviors. The actual construction sequence and the loading of the structure ere not properly represented in the analysis. This paper identifies the source of the errors and develops the algorithm to account for the differential column shortening due to construction dead load based upon a given construction sequence

  • PDF

이동로봇의 추측항법 정확성을 개선하기 위한 자이로스코프의 정확도 교정 (Precision Calibration of Gyroscopes for Improving Dead-Reckoning Accuracy in Mobile Robots)

  • 고재평;윤재무;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제11권5호
    • /
    • pp.463-470
    • /
    • 2005
  • This paper describes a method aimed at improving dead-reckoning accuracy with gyroscopes in mobile robots. The method is a precision calibration procedure for gyroscopes, which effectively reduces the ill effects of nonlinearity of the scale-factor and temperature dependency. This paper also describes the methods of gyro data collection fur all ambient temperature$(-40^{\circ}C{\~}+80^{\circ}C)$ using cubic spline interpolation and defining the error function. The sensor used was a vibrating gyroscope called the EWTS82NA21, which is low lost and commonly used in car navigation system, made by Panasonic. This angular rate sensor utilizes Coriolis force generated by a vibrating tuning fork. The paper also provides experimental results to check the performance and the effectiveness of the proposed method.

교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴 (Switching Signal Patterns to Prevent Short Circuit of AC Choppers)

  • 장도현;연재을
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권9호
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

새로운 축소 모델을 이용한 Smith-Predictor 제어기 설계 (Smith-Predictor Controller Design Using New Reduction Model)

  • 최정내;조준호;황형수
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권1호
    • /
    • pp.9-15
    • /
    • 2003
  • To improve the performance of PID controller of high order systems by model reduction, we proposed two model reduction methods. One, Original model with two point $({\angle}G(jw)=\;-{\pi}/2,\;-{\pi})$ in Nyquist curve used gradient base method and genetic algorithm. The other, Original model without two point$({\angle}G(jw)=\;-{\pi}/2,\;-{\pi})$in Nyquist curve used to add very small dead time. This method has annexed very small dead time on the base model for reduction, and we remove it after getting the reduced model, and , we improved Smith-predictor for a dead-time compensator using genetic algorithms. This method considered four points$({\angle}G(jw)=0,\;-\pi/2,\;-\pi,\;-3\pi/2)$ in the Nyquist curve to reduce steady state error between original and reduced model. It is shown that the proposed methods have more performance than the conventional method.