• Title/Summary/Keyword: daytime

Search Result 1,238, Processing Time 0.026 seconds

Characterizing Regional Ozone Concentration Changes Due to the Adoption of Eco-Friendly Vehicles in South Korea (친환경 자동차 도입에 따른 지역별 오존 농도 변화 특성 분석)

  • Chaeyeong Yang;Wonbae Jeon;DongJin Kim;Jaehyeong Park;Hyeonsik Choe;Jeonghyeok Mun
    • Journal of Environmental Science International
    • /
    • v.32 no.9
    • /
    • pp.613-626
    • /
    • 2023
  • This study investigates the impact of increased adoption of eco-friendly vehicles on ozone (O3) concentrations in South Korea, utilizing the community multiscale air quality (CMAQ) model. In the summer of 2017 (June-August), we conducted two experiments: a BASE experiment, representing baseline emissions, and an R_30 experiment, involving a 30% emission reduction due to eco-friendly vehicles. The contrast between these experiments reveals that, while most air pollutants decreased with reduced vehicle emissions, O3 concentrations surprisingly increased (up to 2.1 parts per billion) across South Korea. A further examination of O3 concentration changes was conducted by analyzing daytime and nighttime variations as well as wind direction. During the daytime, O3 concentrations notably rose near metropolitan areas due to reduced O3 titration (O3 + NO → O2 + NO2) resulting from emission reductions. At nighttime, O3 concentrations exhibited a greater increase, attributed to the transport of daytime-generated O3 to rural regions. Notably, the impact of reduced emissions in metropolitan areas on O3 concentrations in downwind areas varied depending on the prevailing wind direction. These findings highlight that the promotion of eco-friendly vehicles, though effective in lowering certain air pollutants, might not directly influence O3 concentrations. This study underscores the need to comprehensively understand the complicated chemistry of O3 to develop effective strategies for air quality management.

The Effect of the Healthy Lifestyle Habits of College Students Participating in Leisure on the Quality of Sleep (여가참가 대학생의 건강생활습관이 수면의 질에 미치는 영향)

  • Soo-Jin Seo
    • Journal of Industrial Convergence
    • /
    • v.22 no.1
    • /
    • pp.127-135
    • /
    • 2024
  • This study used a convenience sampling method to find out the effect of healthy lifestyle habits of college students participating in leisure activities on sleep quality. The results are as follows. First, in majors according to the personal characteristics of college students, the arts and sports field showed higher exercise lifestyle habits than the natural field, and in leisure participation, college students participating in the sports field showed an effect on exercise lifestyle, health perception habits, eating habits, and subjective sleep. In the leisure activity period, it was found that students who participated in leisure activities for more than 3 years had an effect on exercise lifestyle, health perception habits, and daytime sleep. In leisure activity time, it was found that students who participated for 1-2 hours had an effect on exercise lifestyle, health perception habits, and eating habits. Second, it was found that bad lifestyle habits had an effect on sleep difficulties, and in daytime sleep, exercise lifestyle habits, bad lifestyle habits, and eating habits were found to have an effect.

Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device

  • Huijin Lee;Sungjoon Park;Hyuktae Kwon;Belong Cho;Jin Ho Park;Hae-Young Lee
    • Korean Circulation Journal
    • /
    • v.54 no.2
    • /
    • pp.93-104
    • /
    • 2024
  • Backgrounds and Objectives: This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM). Methods: Forty patients were recruited, and 33 participants were included in the final analysis. Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements. Results: The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg. Mean differences in SBP/DBP between the two devices were 1.74±6.69/-3.24±6.51 mmHg, 0.75±7.44/-4.41±7.42 mmHg, and 4.15±6.15/-0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001). Conclusions: The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.

The Effect of Insomnia Severity on Daytime Sleepiness in Obstructive Sleep Apnea Syndrome (불면증 정도가 폐쇄성 수면무호흡 증후군에서의 주간졸림 정도에 끼치는 영향)

  • Nam, Ji-Won;Shin, Byoung-Hak;Shin, Hyeon-Sil;Park, Minji
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • Objectives: Whether daytime sleepiness is proportional to the severity of sleep apnea in obstructive sleep apnea syndrome (OSAS) is controversial. In this study we investigated how insomnia severity affects the association between daytime sleepiness and sleep apnea severity in OSAS. Methods: The present study included 235 male subjects who were diagnosed with OSAS based on clinical history and nocturnal polysomnography. Pearson's correlation analysis was conducted among sleep and mood-related self-reported data, polysomnographic data and demographic data of all subjects. Based on Pittsburgh Sleep Quality Index (PSQI), the subjects were divided into 2 groups; group A (n = 75; $PSQI{\leq}5$) and group B (n = 160; PSQI > 5). Partial correlation analysis was performed between the Epworth Sleepiness Scale (ESS) and other data in both groups. Multiple linear regression analysis was conducted to investigate the factors which affected the ESS in group A. Results: Pearson's correlation analysis showed weak or non-existent correlations between ESS and apnea severity data such as apnea-hypopnea index (AHI) (r = 0.148, p = 0.023), apnea index (AI) (r = 0.137, p = 0.036), hypopnea index (HI) (r = 0.058, p = 0.377), oxygen desaturation index (ODI) (r = 0.149, p = 0.022) and arousal total index (ATI) (r = 0.129, p = 0.048). Positive correlations between ESS and apnea severity data such as AHI ($r_p=0.313$, p = 0.008), AI ($r_p=0.339$, p = 0.004), ODI ($r_p=0.289$, p = 0.015) and ATI ($r_p=0.256$, p = 0.031) were observed only in group A. Multiple regression analysis showed that AI (t = 2.996, p = 0.004) and BAI (t = 2.721, p = 0.008) were associated with ESS in group A. Conclusion: The correlation between daytime sleepiness and sleep apnea severity was shown only in group A. This result suggests that associations between daytime sleepiness in OSAS and sleep apnea severity will become prominent when controlling for insomnia-related variables.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

An Analysis of Rational Green Area Ratio by Land Use Types for Mitigating Heat-Island Effects (도시열섬완화를 위한 토지 이용 유형별 합리적 녹지율 분석)

  • SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.59-74
    • /
    • 2015
  • The purpose of this study is to analyze reasonable green area ratios for mitigating urban heat island considering various land use types. Land uses of 5 types such as single residential, multi residential, commercial area, public facility, and industrial area were considered. Green areas were extracted from the tree attribution of land cover. Effect of urban heat island was analysed by the surface temperature of ASTER thermal infrared radiance scanned daytime and nighttime. Mitigation effect of green area at daytime was higher than nighttime. Surface temperature of green area was low in single residential at daytime. But the difference of surface temperature by each land use type was small. The effect of surface temperature mitigation of green area was lower in industrial area. The results of reasonable green area ratios for mitigating urban heat island indicate that surface temperature was the lowest with green area ratio of 40~50% in single residential, multi residential, and commercial area at daytime. Surface temperature of nighttime was not changed much by green area ratios. Therefore, the results of this study will be suggested in urban development planning to construct effectively green area for mitigating urban heat island.

Assessment of Surface Temperature Mitigation Effects of Wetlands During Heat and Cold Waves Using Daytime and Nighttime MODIS Land Surface Temperature (Terra/Aqua MODIS LST를 이용한 폭염 및 한파기간 동안 습지의 지면온도 완화효과 분석)

  • Chung, Jeehun;Lee, Yonggwan;Kim, Seongjoon
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.123-133
    • /
    • 2019
  • This study analyzed the surface temperature mitigation effect of wetlands during cold waves (below -12℃ from January to February) and heat waves (above 33℃ from July to August) in 2018. We used Terra/Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) Daytime and Nighttime Land Surface Temperature (LST) product, and the maximum and minimum air temperature observed at 86 stations of Korea Meteorological Administration (KMA). For the cold wave analysis, the LST of Terra MODIS nighttime was the highest at forest area with -12.7℃, followed by upland crop and wetland areas of -12.9℃ and -13.0℃ respectively. The urban area showed the lowest value of -14.4℃. During the heat wave, the urban area was the highest with + 34.6℃ in Aqua MODIS LST daytime. The wetland area was + 33.0℃ showing - 1.6℃ decrease comparing with urban area.

An Estimation of Occupancy Population Using the Expanded Mobile Phone Data (이동통신 자료 전수화를 통한 존재인구 산정 방안)

  • KIM, Kyoung Tae;LEE, Inmook;KWAK, Ho-Chan;MIN, Jae Hong
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.3
    • /
    • pp.222-233
    • /
    • 2016
  • Recently, mobile phone data was applied in travel demand modeling as a new source of dynamic population movement. This study is also aimed to estimate "occupancy population" during a given period of time within a given spatial region using mobile phone data. An occupancy population was defined as the number of people residing or moving within a given time and space. In case of Seoul Metropolitan area, we divided the area into a number of administrative districts as zones for analysis and estimated the occupancy population of each zone by mobile phone data collected by SK telecom Co., a wireless telecommunication provider in Korea. For the expansion of mobile phone data, a new concept of "communication probability" was introduced and applied in the estimation of occupancy population of each zone by the hour. We compared the estimated number with the daytime population and the daytime population index referred by the Statistics Korea. The results showed that a positive correlation existed between the estimated number and the statistical number by nationwide survey. It was concluded that mobile phone data could be more cost-effective sources than a conventional survey method to estimate the pattern of population movement by the hour or by the day.

Nighttime Cooling Is an Effective Method for Improving Milk Production in Lactating Goats Exposed to Hot and Humid Environment

  • Sunagawa, Katsunori;Nagamine, Itsuki;Kamata, Yasuhiro;Niino, Noriko;Taniyama, Yoshihiko;Kinjo, Kazuhide;Matayoshi, Ayano
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.7
    • /
    • pp.966-975
    • /
    • 2015
  • Heat production in ruminants follows a diurnal pattern over the course of a day peaking 3 hours following afternoon feeding and then gradually declining to its lowest point prior to morning feeding. In order to clarify the cooling period most effective in reducing decreases in feed intake and milk production, experiments were carried out based on the diurnal rhythm of heat production and heat dissipation. In experiment 1, the effects of hot environment on milk production were investigated. The animals were kept first in a thermoneutral environment ($20.0^{\circ}C$, 80.0%) for 12 days, they were then transitioned to a hot environment ($32^{\circ}C$, 80.0%) for 13 days before being returned to second thermoneutral environment for a further 12 days. In experiment 2, the effectiveness of daytime cooling or nighttime cooling for improving milk production in hot environment was compared. While ten lactating Japanese Saanen goats (aged 2 years, weighing 41.0 kg) during early lactation were used in experiment 1, ten lactating goats (aged 2 years, weighing 47.5 kg) during mid-lactation were used in experiment 2. The animals were fed 300 g of concentrated feed and excessive amounts of crushed alfalfa hay cubes twice daily. Water was given ad libitum. The animals were milked twice daily. When exposed to a hot environment, milk yield and composition decreased significantly (p<0.05). Milk yield in the hot environment did not change with daytime cooling, but tended to increase with nighttime cooling. Compared to the daytime cooling, milk components percentages in the nighttime cooling were not significantly different but the milk components yields in the nighttime cooling were significantly higher (p<0.05). The results indicate that nighttime cooling is more effective than daytime cooling in the reduction of milk production declines in lactating goats exposed to a hot environment.

Microclimate in Rice Nursery Bed Covered with Various Materials (벼 보온못자리 피복재질에 따른 상내 미기상 특성)

  • Hwang Kyu Hong;Lee Jeong Taek;Yun Jin Il;Shim Kyo Moon;Hur Seung Oh
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.87-94
    • /
    • 2000
  • To recommend adequate covering materials and shapes of rice nursery bed for mechanical transplanting rice seedling, measuring of microclimate inside the rice nursery protected by polyethylene tunnel type, polyester tunnel type, and polyester flat type was compared to that outside the nursery. The vapor pressure deficit inside the polyester tunnel and polyethylene tunnel was higher than that outside the tunnel during daytime on a sunny day. During daytime on cloudy with rain day, the vapor pressure deficit inside polyester tunnel was higher than that in polyethylene tunnel or outside the nursery tunnel. The heat fluxes in the rice nursery tunnel during daytime flowed more to the soil than to the outside tunnel. Amounts of soil heat fluxes in polyethylene tunnel were higher than in polyester flat and polyester tunnel. The vertical profile of air temperature inside the nursery tunnel came to inversion during daytime and was lapse during nighttime regardless weather condition. The maximum temperature inside the nursery tunnel were 47.2$^{\circ}C$ in polyethylene tunnel and 37.$0^{\circ}C$ in polyester tunnel which was 21.1$^{\circ}C$ and 10.9$^{\circ}C$ higher than outside the tunnels respectively on sunny day. On cloudy with rain day, the temperature inside nursery tunnel was higher 8.4$^{\circ}C$ and 4.$0^{\circ}C$ polyethylene and polyester tunnel respectively then outside. Daily temperature changes became larger in the polyethylene tunnel, polyester tunnel, and outside the nursery tunnel in order. The rice seedling growth in polyester tunnel was better than the other nursery beds.

  • PDF