• Title/Summary/Keyword: daylighting performance

Search Result 125, Processing Time 0.024 seconds

Daylighting Performance of a New-Developed Energy Efficient Double-Skin Window System (에너지절약형 이중외피 창호의 기본채광 성능)

  • Park, Jong-Myung;Kim, Jae-Hoon;Choi, Jin-Woo;Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.117-122
    • /
    • 2008
  • The apartment will be much more convenient than the other one in the application of green technologies, providing the merits by mass production. For example, pre-manufactured building materials can be effectively adapted to the formation of buildings. Recently, the form of double-enveloped window system has been developed for the purposed of minimizing energy loss occurred around windows. On the other hand, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. A various types of glass can be applied to the window system and it plays a critical role in the determination of inner visual environment. For the purpose of verifying the potential of its daylighting, a mock-up model has been constructed and tested. The refurbished version of conventional window shows its illuminated characteristics. Clear and Low-e glass have been adapted for window area and daylighting ratio has been compared in both test cells.

  • PDF

Interior Partitioned Layout and Daylighting Energy Performance in Office Buildings

  • Kim, Gon
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • In this age of "Information", many people consider it a deterrent to information flow to provide a hierarchy with private rooms in a modern office layout. There are others, however, who insist that visual and acoustical privacy are more important than any other design factor in achieving higher productivity. The debate may never end, but the partitioned open plan, which is a new form of the vast open plan, has merits of each concept - open and closed layout. Consequently, office design has dramatically shifted to partitioned open planning, with shorter, temporary walls or partitions, originally intended for increasing privacy and diminishing hierarchy, yet still keeping flexibility in spatial organization. The introduction of low-level partitioned spaces in an office layout, however, produces a complicated lighting design problem. Obviously, accurately predicted daylighting performance data are needed not only for daylighting design but for artificial lighting system design. Scale models of 12 sets of unit partitioned spaces are constructed and extensive scale model measurements of both daylight and reflected sunlight have been performed within an artificial sky simulator. The prototype-building interior is modeled with different partition configurations, each of which is modeled using the different envelope geometry and exterior configurations, and then the variations in interior light levels are estimated. The result indicates that partitioned spaces employed in an open plan of modern offices still offer a large potential for daylighting and energy saving as well. Much of the savings may derive from the cumulative effect of reflected sunlight. Optimal design for building envelope geometry and exterior configuration promises additional savings.

  • PDF

Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses (공동주택의 배치유형에 따른 창호 시스템의 채광특성)

  • Kim, Gon;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

Development and Validation of Sky Simulator for Reproducing CIE Overcast Sky Model (돔형 인공천공의 개발 및 CIE표준담천공 구현 검증에 관한 연구)

  • Shin, Ju Young;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.97-103
    • /
    • 2010
  • Sky simulator is a effective daylighting design tool that can evaluate three dimensional performance of lighting. Especially, the dome type sky simulator offer reliable and reproducible daylighting performance with different standard sky models. Recently, K university has developed the dome type sky simulator(sky dome) with the diameter of 6.5m and the height of 3.7m. The sky dome consists of a group of 145 large steel panels with 72 halogen lamps which are arranged in a circular array. The luminance distribution of the sky dome can be calibrated by changing the angle and the brightness of the lamps respectively. To allow more reliable prediction and evaluation of daylighting through the sky dome, It is essential to validate the sky luminance distribution of the sky dome. This study consider the validation of the comparisons between the measured and the calculated luminance values for the CIE standard overcast sky. Also, the error rate between the measured and the calculated luminance values were compared to the previous studies. The results indicated that the K university sky dome can reproduce reliable CIE standard overcast sky with the average relative error rate of 4.4% and root-mean-square error(RMSE) of 5.4%.

Daylighting Performance of Topside Lighting Systems for Different Orientations (방위에 따른 정측창 시스템의 채광성능 평가)

  • Kong, Hyo-Joo;Lee, Jin-Seoung;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Daylighting is core of sustainable design in most buildings. Well-designed daylighting systems can significantly reduce or even eliminate the electric lighting loads during the day time, including air conditioning energy loads. Among window systems. the topside lights systems including monitor lighting, sawtooth lighting, sunscoop and, lightscoop is one of the most popular apparatus to improve the lighting quantity. Also they are important both in terms of energy savings and visual quality. The objective of this study is to analyse daylighting performance of topside lighting system for different orientations. Four types of topside lighting system were tested and comparpd: monitor lighting, sawtooth lighting, lightscoop and sunscoop. Totally 25 measuring points of illuminance on the horizontal plane were monitored from 09:00 to 17:00 on October 6, 2008. Agilent data logger and photometric sensors Li-cor were used. Comparisons with a light factor is discussed. The results found in this study would mean that there were no significant differences in light factor between three cases.

Evaluation of Seasonal Daylighting Performance according to Window Compositions of Double Skin Facades (이중외피 창호특성에 따른 계절별 실내 주광환경 평가)

  • Lim, Tae-Sub;Kang, Seung-Mo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.4
    • /
    • pp.91-98
    • /
    • 2015
  • Double skin façade is known that several features affected the building energy and daylighting performance. That is why the envelope is able to consist of all architectural materials such as glass, aluminum, wood and insulation for vision of residents and workers in buildings. Its specifications is very diverse according to the building designers and building owners. In recent times, visual environment became a major focus and resulted in the development of cutting edge engineering of diverse glazing systems and shading devices by growing interests of friendly environment. Thus this research has evaluated the fluctuations of interior lighting and atmospheric conditions based on double skin facade systems. Especially in terms of daylighting environment as dependent on solar variations, this research provides quantitative analysis of interior lighting conditions and how it affects the living conditions as well as improve the design of interior spaces.

Development of Solar Daylighting System Using Parabolic Mirrors (포물면 집광거울 방식의 태양광 집광채광시스템 개발)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Jong-Min;Joung, Che-Bong;Kim, Byung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.240-245
    • /
    • 2013
  • We developed a parabolic reflector based daylighting system which can be used as an alternative indoor daytime lighting device such as for fluorescent lamps. The system comprises three main components : a daylight concentrator made of 4 pairs of parabolic reflectors and mirrors, a silica optical fiber bundle based light transmitter, and 4 light diffusers for the final indoor delivery of the collected daylight. We analyzed the performance of the system and revealed the system efficiency and daylighting factor. All test methods follow the rule, NR PV601 : 2007-daylighting system, governed by Korea Energy Management Corporation.

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator (광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구)

  • Oh, Seung Jin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.124-132
    • /
    • 2012
  • This study presents the simulation results of Photopia when a lecture room with north-facing windows were illuminated by two different types of daylighting systems to improve the imbalance in its lighting conditions. Especially, the candela power distribution curves (CDCs) on a clear sunny day at the summer solstice, reaching $80^{\circ}$ in solar altitude, were analyzed with respect to the illuminance available at task areas (work planes). The difference between its illuminance on the north and south areas exceeded 1,000 lux without any daylighting system. This, however, decreased drastically with the application of a daylighting system. When a light tube system was introduced, it reduced from 906lx to 603lx and, even further to 308lx with the application of a dish concentrator system. Generally, the performance of a light tube system was greatly influenced by solar altitude while its effect on the dish concentrator system was rather negligible.

Daylighting Performance Nomographs for Toplit Atrium (아트리움의 자연채광 성능 예측용 노모그래프)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.