• Title/Summary/Keyword: daylight

Search Result 460, Processing Time 0.025 seconds

A Study on the Daylight Distribution Analysis in different Height of Roller Shade in a Small Office (Roller Shade 높이 조절에 따른 사무소 건축물의 주광유입분포 분석에 관한 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.17-20
    • /
    • 2008
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in the room. But, it has a problem of an excessive direct sunlight. This study analyzed daylight distribution characteristic by roller shade systems with a Mock-up test. With three 1/2 Scale Mock-up rooms, we performed a test of daylight distribution performance in different shade height of each room through the different height of roller shade. systems. This research will be used as a fundamental study for automated roller shade systems.

  • PDF

Study on Comparative Analysis of Daylight Evaluation Tools for Building Environment (건물 주광환경 평가도구의 비교분석에 관한 연구)

  • Park, K.E.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2002
  • Daylighting in building is very important as it has an effect on work performance as well as on their visual health. It is also regarded as a good energy conservation measure in saving energy used for lighting. There are many daylighting evaluation tools such as empirical equations, tables, nomograms, diagrams, protractors, computer simulation, scale models. This study conducted initial daylight measurements to analyze luminous environment in classrooms of elementary school and comparative analysis on three daylighting evaluation tools, such as daylight factor calculation formula, the graphic method with BRE Protractor and computer simulation with Adeline 3.0. It is found that the computer simulation tool produced the closest result to actual measurements of luminous environment in elementary school classroom, and the other simplified tools made appropriate results so that they can be used in the early stage of daylighting design process.

Analysis of Requirements for Night Vision Imaging System (야시조명계통 요구도 분석)

  • Kwon, Jong-Kwang;Lee, Dae-Yearl;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

Analysis of Daylight Availability Rights using 3D City-Model (3차원 도시모델을 이용한 건물 일조권 분석)

  • Yoo, Hwan-Hee;Goo, Sin-Hoi;Cho, Eun-Rae;Kim, Seong-Sam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.2
    • /
    • pp.165-175
    • /
    • 2007
  • Nowadays, architecture in urban areas is dominated by the goal of spanning wide spaces and creating openings large enough to distribute daylight to building interiors. Daylight availability of building in city strongly depends not only on the building's height but also on spaces between buildings. Recently numbers of disputes over the daylight availability are increasing in high density developed areas because residents' demand for pleasant residential environment is getting stronger. Therefore in this study we constructed the three-dimensional information of buildings using LiDAR data connected with digital map and then suggested conclusions by applying it to daylight availability analysis. This study presents an approach to judge accurately the violation of a right to enjoy sunshine by using altitude and azimuths of the sun, simulating three-dimensional urban space precisely, and classifying the total duration of sunshine and the continuous duration of sunshine each householder. We expect that local government performs precisely the confirmation and permission business about urban planning and design by advising this approach.

A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.

Illumination Simulation of the Daylight using AGI S/W Program (AGI 프로그램을 활용한 자연광 조도시뮬레이션)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.58-62
    • /
    • 2017
  • In this study, the design conditions for the Korean-style glass greenhouse structure has been reduced to achieve the most efficient use of natural light. The AGI program was simulated for the optimal conditions of daylight in a glass greenhouse. From the results of daylight simulation, the axis position of the glass greenhouse's roof was not an important factor in the daylight effects regarding illumination and uniformity. In summer, there were long periods of daylight and high illumination levels. The illumination value of daylighting increased with increasing glass transparency value, and the illumination value was greatest at 14:00 hours. At this time, the rate of light variation according to the glass transparency was 89 [lux/%]. In addition, the optimal design conditions for the glass greenhouse were established, which were a $30[^{\circ}]$ or $150[^{\circ}]$ installation angle and higher transmittance of glass.

The Analysis of View and Daylights for the Design of Public Housing Complexes Using a Residential Environment Analysis System Integrated into a CAD System (주거환경분석시스템의 CAD 시스템 통합을 통한 공동주택단지설계 시 일조 및 조망분석에 관한 연구)

  • Park, Soo-Hoon;Ryu, Jeong-Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.2
    • /
    • pp.137-145
    • /
    • 2007
  • This paper concerns about residential environment analysis program implementation for design and analysis on public housing complexes such that view and daylight analysis processes are automated and integrated into existing design routine to achieve better design efficiency. Considering the architectural design trends this paper chooses ArchiCAD as a platform for a CAD system, which contains the concepts such as integrated object-oriented CAD, virtual building and BIM. Residential environment analysis system consists of three components. The first component is the 3D modeling part defining 3D form information for external geographic contour models, site models and interior/exterior of apartment buildings. The second is the parametric library part handling the design parameters for view and daylight analysis. The last is the user interface for the input/output and integration of data for the environment analysis. Daylight analysis shows rendered images as well as results of daylight reports and grades per time and performs the calculations for floor shadow. It separates the site-only analysis from the analysis of site and exterior environmental parameters. View analysis considers horizontal and vertical view angles to produce view image from each unit and uses the bitmap analysis method to determine opening ratio, scenery ratio and void ratio. We could expect better performance and precision from this residential environment analysis system than the existing 2D drawing based view and daylight analysis methods and overcome the existing one-way flow of design information from 3D form to analysis reports so that site design modifications are automatically reflected on analysis results. Each part is developed in a module so that further integration and extension into other related estimation and construction management systems are made possible.

A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems (가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • This research aimed to generate two points of daylighting application as follows: 1) providing daylight performance data with a variety of glazing materials for a large window and 2) designing and evaluating an experimental type of differentiated window. For this purpose, we compared the daylight and distribution performance of new defined type of window configuration to the conventional window counterpart with a variety of glazing materials. The comparison was made for a deep, south-facing perimeter zone with large window, without any interior obstruction. The conventional window is the base single homogeneous glass pane, where as the differentiated window uses of two different glazings; an upper daylight glazing with high visible transmission and lower view window with lower transmittal glass. The daylight performance data was translated into a ratio between outdoor illuminance and the interiors. The simulated analysis of the conventional window indicates that the interior light levels have been changed proportionally dependent on the transmittance of the applied glass. The comparison of daylight distribution analysis showed that the differentiated window has lots of photometric advantage by the optical function of upper daylight window. In particular, the contribution of higher daylight window into deep rear space must be stressed for daylighting application.

Effects of the Daylight Disturbance on the Growth and Yield of Cut Flower Rose 'Monet' (Rosa hybrida cv. 'Monet') (일조방해가 절화 장미의 생육 및 수량에 미치는 영향)

  • Yuri, Lee;Sang Kun, Park
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.24 no.4
    • /
    • pp.30-34
    • /
    • 2022
  • This study was carried out to analyze the effect of changes in the light environment caused by the daylight disturbance on the productivity and quality of the standard cut flower rose cultivar 'Monet'. It was artificially shaded to obstruct the sunlight and the productivity and growing characteristics of roses according to the time of daylight disturbance were investigated. The number of cut flowers per unit area (3.3m2) of the cut flower rose 'Monet' was 40 stems in the control, while in the 4-hour, 8-hour, and 12-hour treatments, it was 32, 29, and 25, respectively. As the daylight disturbance time was increased, the number of cut flowers showed a tendency to decrease. In the case of cut flower characteristics related to the quality of cut roses, all characteristics such as flower width, flower height, petal length, and petal width, decreased by 10 to 20% in the 12-hour treatment compared to the control. In addition, growth characteristics such as peduncle length, peduncle thickness, and cut flower height, which determine the marketability of cut roses, also tended to decrease as the daylight disturbance time increased. On the other hand, the number of days to flowering increased by 14.0% from 24.3 to 27.7. The overall growth characteristics were contracted and flowering was delayed as the time of daylight disturbance increased. In the results of this study, as the daylight disturbance time increased, flower size, cut flower length, and fresh weight was decreased. This is due to the decrease in the total photosynthetic amount as the daily average photosynthetic photon flux density (PPFD) was decreased, resulting in a decrease in the quality of roses. It is judged that it is because they do not receive enough carbohydrates necessary for growth and development.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.