• 제목/요약/키워드: dampers

검색결과 1,032건 처리시간 0.03초

Numerical study on the mitigation of rain-wind induced vibrations of stay cables with dampers

  • Li, Shouying;Wu, Teng;Li, Shouke;Gu, Ming
    • Wind and Structures
    • /
    • 제23권6호
    • /
    • pp.615-639
    • /
    • 2016
  • Although the underlying mechanism of rain-wind induced vibrations (RWIVs) of stay cables has not been fully understood, some countermeasures have been successfully applied to mitigating this kind of vibration. Among these, installing dampers near the bridge deck was widely adopted, and several field observations have shown its effectiveness. In this study, the effectiveness of dampers to RWIVs of stay cables is numerically investigated comprehensively by means of finite difference method (FDM). Based on the free vibration analysis of a taut string, it is found that the 3-points triangle scheme, which can be easily implemented in FDM, can offer an excellent approximation of the concentrated damping coefficient (expressed as a Dirac delta function) at the location where the damper is installed. Then, free vibration analysis of a 3-D continuous stay cable attached with two dampers is carried out to study the relationship of modal damping ratio and damping coefficient of the dampers. The effects of orientation of the dampers and cable sag on the modal damping ratio are investigated in detail. Finally, the RWIV response of a 3-D continuous stay cable attached with two dampers is examined. The results indicate that 0.5% of damping ratio is sufficient to reduce the RWIV vibration of the Cable A20 on the No.2 Nanjing Bridge over Yangtze River.

비연성 철근 콘크리트 중력 프레임에 의한 지진 보강 (Seismic Rehabilitation of Nonductile Reidorced Concrete Gravity Frame)

  • Dong Choon Choi;Javeed A. Munsh;Kwang W. Kim
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.116-123
    • /
    • 2001
  • This paper represents results of an effort to seismically rehabilitate a 12-story nonductile reinforced concrete frame building. The frame located in the most severe seismic area, zone 4, is assumed to be designed and detailed for gravity load requirements only. Both pushover and nonlinear time-history analyses are carried out to determine strength, deformation capacity and the vulnerability of the building. The analysis indicates a drift concentration at the $1^{st}$ floor level due to inadequate strength and ductility capacity of the ground floor columns. The capacity curve of the structure, when superimposed on the average demand response spectrum for the ensemble of scaled earthquakes indicates that the structure is extremely weak and requires a major retrofit. The retrofit of the building is attempted using viscoelastic (VE) dampers. The dampers at each floor level are sized in order to reduce the elastic story drift ratios to within 1%. It is found that this requires substantially large dampers that are not practically feasible. With practical size dampers, the analyses of the viscoelastically damped building indicates that the damper sizes provided are not sufficient enough to remove the biased response and drift concentration of the building. The results indicate that VE-dampers alone are not sufficient to rehabilitate such a concrete frame. Concrete buildings, in general, being stiffer require larger dampers. The second rehabilitation strategy uses concrete shearwalls. Shearwalls increased stiffness and strength of the building, which resulted in reducing the drift significantly. The effectiveness of VE-dampers in conjunction with stiff shearwalls was also studied. Considering the economy and effectiveness, it is concluded that shearwalls were the most feasible solution for seismic rehabilitation of such buildings.

  • PDF

강재댐퍼로 보강된 철근콘크리트 골조의 내진성능 실험 연구 (An Experimental Study on the Seismic Performance of RC Frames with Steel Dampers)

  • 박지영
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.43-50
    • /
    • 2010
  • 본 연구에서는 RC골조의 내진보강을 위해 K형브레이스로 지지되는 강재댐퍼 설치방식을 제안하고 강재댐퍼에 의한 RC골조의 내진보강효과를 실험 및 설계식의 비교를 통해 검증하였다. 강재댐퍼로 보강된 RC골조의 성능은 RC골조 및 강재댐퍼의 강도-변형 관계를 각각 산정한 후 조합하여 산정하였다. 강재댐퍼 지지부재의 강성이 충분히 크지 않을 경우 댐퍼의 성능이 제대로 발휘될 수 없으므로 댐퍼의 지지부재인 브레이스의 강성 고려하여 강재댐퍼의 성능을 산정 하였다. 강재댐퍼 보강 RC골조의 내진보강효과를 확인하기 위한 실험은 비보강 RC골조를 기준 실험체로 하고 K형브레이스로 지지되는 강재 댐퍼의 설치 방법을 변수로 하여 횡력에 대한 실험체의 강도, 강성, 이력특성 등의 항목에 대해 평가하였다. 강재댐퍼 보강 RC골조는 강도, 강성, 에너지소산능력이 비보강 RC골조에 비해 우수한 것으로 나타나 강재댐퍼에 의한 보강효과를 확인할 수 있었다. 강재댐퍼 보강 RC골조의 실험결과와 설계식에 의한 성능을 비교한 결과 설계식이 강재댐퍼 보강 RC골조의 성능을 비교적 유사하게 나타낼 수 있는 것으로 검증되었다.

교량의 내진설계에 있어서 점성감쇠기능받침의 감쇠계수 영향평가 (Effect of Damping Coefficients in Earthquakes Resistant Design with Viscous Dampers for Bridges)

  • 정상모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.399-406
    • /
    • 2000
  • Viscous dampers have been utilized as bearings and STU`s (Shock Transmission Unit) in earthquake resistant designs for bridges. Some viscous dampers are used as energy dissipators on one hand, but some dampers such as STU`s are used as fixing devices during an earthquake on the other hand. This paper discusses the effect of viscous dampers on the response of bridge with respect to the magnitude of damping coefficients. For this purpose, a typical bridge was taken as an example, and time-history dynamic analysis have been carried out. The input seismic data used in the analyses are relevant to the response spectra in the Koreans design code. The results show that there is an optimum value of coefficient considered most effective in the design. A STU with a large value of coefficient seems to make its support fixed. The response of the bridge is not much sensitive to the variation of the damping coefficients.

  • PDF

Shaking table study of a 2/5 scale steel frame with new viscoelastic dampers

  • Chang, K.C.;Tsai, M.H.;Lai, M.L.
    • Structural Engineering and Mechanics
    • /
    • 제11권3호
    • /
    • pp.273-286
    • /
    • 2001
  • Viscoelastic (VE) dampers have shown to be capable of providing structures with considerable additional damping to reduce the dynamic response of structures. However, the VE material appears to be sensitive to the variations in ambient temperature and vibration frequency. To minimize these effects, a new VE material has been developed. This new material shows less sensitivity to variations in vibration frequency and temperature. However, it is highly dependent on the shear strain. Experimental studies on the seismic behavior of a 2/5 scale five-story steel frame with these new VE dampers have been carried out. Test results show that the structural response can be effectively reduced due to the added stiffness and damping provided by the new type of VE dampers under both mild and strong earthquake ground motions. In addition, analytical studies have been carried out to describe the strain-dependent behavior of the VE damper. The dynamic properties and hysteresis behavior of the dampers can be simulated by a simple bilinear model based on the equivalent dissipated energy principle proposed in this study.

자기 유변 유체를 이용한 각도 제한 회전 감쇠기 설계 및 응용 (Constrained rotary MR damper design and its application)

  • 김상화;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.191-194
    • /
    • 1997
  • Passive, semi-active and active dampers have been used to dissipate energy in mechanical systems. Semi-active dampers have higher performance than passive dampers and require lower power to operate than active dampers. Its damping characteristics can be changed appropriately for varying conditions. In this paper, we developed a semi-active damper based on Magnetorheological(MR) fluid. MR fluid has a variable damping characteristics proportional for the magnetic field intensity. It has several advantages such as high strength, low viscosity, robustness in impurities and wide temperature range of operational stability. We designed a constrained rotary MR damper base on valve mode which can dissipate more energy per unit volume. The system with Bingham characteristics is obtained and proved by the experiment.

  • PDF

점성감쇠기가 설치된 건물의 내풍해석 (Wind-induced Vibration of Building Structures with Viscoelastic Dampers)

  • 주석준;민경원;홍성목
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.130-135
    • /
    • 1995
  • Wind-induced vibration of buildings with viscoelastic dampers are studied analytically. The added viscoelastic dampers change the damping distribution and reduce the response of buildings. The distribution of damping resistance that results from these viscoelastic dampers is known as non-classical or non-proportional. Non-classically damped structures are analyzed by state-space approach. However, this approach is complex and time-consumming compared to classical approach. This paper is aimed at the analysis of wind-induced Vibration Of buildings With Viscoelastic dampers. The Process Of State-Space approach is studied and the approximate analysis is suggested to overcome the complex and time-consuming access. For numerical certification, PSDF(Power Spectral Density Function) is obtained. Autocorrelation function is obtained in time domain and PSDF is obtained by fourier transformation of this function in frequency domain. It is found that Approximate method can give close approximation to exact solution.

  • PDF

붕괴하중을 받는 MR 댐퍼의 Bingham 모델을 이용한 저항성능 정해 (Exact Solution for Resistance Capacity utilizing Bingham Model of MR Dampers under Collapse Load)

  • 성지영;민경원;김진구
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.234-240
    • /
    • 2011
  • This study deals with progressive collapse of a structure retrofitted with MR dampers. In order to assess their effect of mitigation which prevents progressive collapse, control force ratio is defined by friction force of MR dampers divided by external force. First, simple model of a structure with MR dampers is suggested. Using the model, exact solution with the control force ratio is obtained. When and where the system is stopped is predicted by the derived solution. Through the dissipated energy by MR dampers during collapse event, equivalent damping ratio is derived. Finally, comparison of exact and equivalent solutions is presented.

Seismic design of a precast r.c. structure equipped with viscous dampers

  • Silvestri, Stefano;Gasparini, Giada;Trombetti, Tomaso
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.297-321
    • /
    • 2011
  • The seismic design of a two-storey precast reinforced-concrete building structure equipped with viscous dampers is presented in this paper with twofold purpose. The first goal is to verify the applicability of a practical procedure for the identification of the mechanical characteristics of the viscous dampers which allow to achieve target performance levels, originally proposed by the authors for moment-resisting building frames, also with reference to "pendular" structures. The second goal is to investigate the effectiveness of the use of viscous dampers (as compared with traditional lateral-resisting stiff braces) for the seismic design of precast not moment-resisting concrete structures.

점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material)

  • 이호;이상엽
    • 한국공간구조학회논문집
    • /
    • 제2권3호
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF