• 제목/요약/키워드: damped structure

검색결과 110건 처리시간 0.025초

유한용소법을 이용한 점탄성 감쇠구조물이 포함된 2단 탄성마운트 시스템의 진동/충격응답 해석 (Finite Element Vibration/Shock Analysis of Double Stage Elastic Mounting System with Viscoelastically Damped Foundation Structure)

  • 정우진;류정수;배수룡;함일배
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.508-516
    • /
    • 2000
  • To study the possibility of F.E.M application to vibration and shock response of double stage elastic mounting system with complicated damped foundation structure like common-bed or raft in ships foundation structure model which has complicated damped sandwich cross-section is analyzed first. And then vibration responses experimental results and shock response of double stage elastic mounting system with complicated damped foundation structure like common-bed or raft in ships foundation structure model which adopts the above damped structure as intermediate foundation were compared. As a result it is found that F.E.M could be effectively used in analyzing the vibration and shock response of double and multi-stage elastic mounting system with complicated damped foundation structures.

  • PDF

FE model updating method incorporating damping matrices for structural dynamic modifications

  • Arora, Vikas
    • Structural Engineering and Mechanics
    • /
    • 제52권2호
    • /
    • pp.261-274
    • /
    • 2014
  • An accurate finite element (FE) model of a structure is essential for predicting reliably its dynamic characteristics. Such a model is used to predict the effects of structural modifications for dynamic design of the structure. These modifications may be imposed by design alterations for operating reasons. Most of the model updating techniques neglect damping and so these updated models can't be used for accurate prediction of vibration amplitudes. This paper deals with the basic formulation of damped finite element model updating method and its use for structural dynamic modifications. In this damped damped finite element model updating method, damping matrices are updated along with mass and stiffness matrices. The damping matrices are updated by updating the damping coefficients. A case involving actual measured data for the case of F-shaped test structure, which resembles the skeleton of a drilling machine is used to evaluate the effectiveness of damped FE model updating method for accurate prediction of the vibration levels and thus its use for structural dynamic modifications. It can be concluded from the study that damped updated FE model updating can be used for structural dynamic modifications with confidence.

마찰 감쇠기를 사용한 구조물의 보강 설계법 제안 (Seismic Retrofit Design Procedure Using a Friction Damper)

  • 문기훈;한상환;조한철;이강석
    • 한국지진공학회논문집
    • /
    • 제15권6호
    • /
    • pp.45-53
    • /
    • 2011
  • 본 연구의 목적은 마찰 감쇠기를 사용한 기존 구조물의 제진보강 설계절차를 제시하는 것이다. 보강된 구조물의 목표 지붕층 변위는 기존 구조물이 급격한 강도의 저감없이 보유내력을 발휘할 수 있는 최대변위를 초과하지 않도록 결정하였다. 보강 구조물의 변위는 비탄성 변위비 제안식을 이용하여 예측하였다. 제안된 방법의 유효성을 검증하기 위하여 80개의 지반운동 데이터를 사용하여 비선형 동적해석을 수행하였다. 해석결과 제안된 방법은 보강 구조물의 지붕층 변위를 정확히 예측할 수 있는 것으로 나타났다.

감도계수 반복법을 이용한 비비례감쇠계의 고유치 및 고유벡터 변화량 해석 (Analysis of Eigenderivative for the Non-Proportional Damped Structure Using the Iterative Method of the Sensitivity Coefficient)

  • 이정윤
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.750-756
    • /
    • 2006
  • This study predicts the modified eigenvectors and eigenvalues of the non-proportional damped structure due to the change in the mass, damping and stiffness of structure by iterative method of the sensitivity coefficient using the original dynamic characteristic. The method is applied to the non-proportional damped 3 degree of freedom system by modifying the mass, damping and stiffness. The predicted dynamic characteristics are showed a good agreement with these from the structural reanalysis using the modified mass, damping and stiffness.

Seismic retrofit of a framed structure using damped cable systems

  • Naeem, Asad;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제29권3호
    • /
    • pp.287-299
    • /
    • 2018
  • The purpose of this study is to investigate the effectiveness of damped cable systems (DCS) to mitigate the earthquake-induced responses of a building frame structure. The seismic performance of the DCS is investigated using the fragility analysis and life cycle cost evaluation of an existing building retrofitted with the DCS, and the results are compared with the structure retrofitted with conventional fluid viscous dampers. The comparison of the analysis results reveals that, due to the self-centering capability of the DCS, residual displacement approximately reaches to zero for the structure retrofitted with the DCS. The fragility analysis shows that the structure retrofitted with the DCS has the least probability of reaching the specific limit states compared to the bare structure and the structure with the conventional fluid viscous damper (VD), especially under the severe ground motions. It is also observed that both the initial and the life cycle costs of the DCS seismic retrofitting technique is lesser compare to the structure retrofitted with the VD.

질량과 강성 변경 따른 감쇠구조물의 동특성 변화 해석 (Eigenderivative Analysis of the Damped Structurure due to Modification of Mass and Stiffness)

  • 이정윤
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2005
  • This study predicts the modified eigenvectors and eigenvalues of the damped structure due to the change in the mass, damping and stiffness of structure by calculation of the sensitivity coefficient using the original dynamic characteristic. The method is applied to examples of the damped 3 degree of freedom system by modifing the mass, damping and stiffness. The predicted dynamic characteristics are in good agreement with these from the structural reanalysis using the modified mass, damping and stiffness.

복합감쇠보의 진동해석을 위한 등가보요소의 개발 (Equivalent Beam Element for Vibration Analysis of Damped Composite Beam Structure)

  • 원성규;정의봉;배수룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.844-847
    • /
    • 2006
  • In this paper, the forced vibration of damped composite beam with I-type section was analyzed. The damping material was assumed to have complex Young's modulus. Damped composite beam structure could be modeled using equivalent beam elements with less D.O.F. rather than solid elements. Finite element method for 6 D.O.F. equivalent beam element was formulated and programmed using complex values. The results of frequency responses revealed good agreement with those of NASTRAN in both Euler beam model and Timoshenko beam model.

  • PDF

Blind modal identification of output-only non-proportionally-damped structures by time-frequency complex independent component analysis

  • Nagarajaiah, Satish;Yang, Yongchao
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.81-97
    • /
    • 2015
  • Recently, a new output-only modal identification method based on time-frequency independent component analysis (ICA) has been developed by the authors and shown to be useful for even highly-damped structures. In many cases, it is of interest to identify the complex modes of structures with non-proportional damping. This study extends the time-frequency ICA based method to a complex ICA formulation for output-only modal identification of non-proportionally-damped structures. The connection is established between complex ICA model and the complex-valued modal expansion with sparse time-frequency representation, thereby blindly separating the measured structural responses into the complex mode matrix and complex-valued modal responses. Numerical simulation on a non-proportionally-damped system, laboratory experiment on a highly-damped three-story frame, and a real-world highly-damped base-isolated structure identification example demonstrate the capability of the time-frequency complex ICA method for identification of structures with complex modes in a straightforward and efficient manner.

Optimum LCVA for suppressing harmonic vibration of damped structures

  • Shum, K.M.;Xu, Y.L.;Leung, H.Y.
    • Smart Structures and Systems
    • /
    • 제20권4호
    • /
    • pp.461-472
    • /
    • 2017
  • Explicit design formulae of liquid column vibration absorber (LCVA) for suppressing harmonic vibration of structures with small inherent structural damping are developed in this study. The developed design formulae are also applicable to the design of a tuned mass damper (TMD) and a tuned liquid column damper (TLCD) for damped structures under harmonic force excitation. The optimum parameters of LCVA for suppressing harmonic vibration of undamped structures are first derived. Numerical searching of the optimum parameters of tuned vibration absorber system for suppressing harmonic vibration of damped structure is conducted. Explicit formulae for these optimum parameters are then obtained by a series of curve fitting techniques. The analytical result shows that the control performance of TLCD for reducing harmonic vibration of undamped structure is always better than that of non-uniform LCVA for same mass and length ratios. As for the effects of structural damping on the optimum parameters, it is found that the optimum tuning ratio decreases and the optimum damping ratio increases as the structural damping is increased. Furthermore, the optimum head loss coefficient is inversely proportional to the amplitude of excitation force and increases as the structural damping is increased. Numerical verification of the developed explicit design expressions is also conducted and the developed expressions are demonstrated to be reasonably accurate for design purposes.

Forced vibration analysis of damped beam structures with composite cross-section using Timoshenko beam element

  • Won, S.G.;Bae, S.H.;Jeong, W.B.;Cho, J.R.;Bae, S.R.
    • Structural Engineering and Mechanics
    • /
    • 제43권1호
    • /
    • pp.15-30
    • /
    • 2012
  • A damped Timoshenko beam element is introduced for the DOF-efficient forced vibration analysis of beam-like structures coated with viscoelastic damping layers. The rotary inertia as well as the shear deformation is considered, and the damping effect of viscoelastic layers is modeled as an imaginary loss factor in the complex shear modulus. A complex composite cross-section of structures is replaced with a homogeneous one by means of the transformed section approach in order to construct an equivalent single-layer finite element model capable of employing the standard $C^{0}$-continuity basis functions. The numerical reliability and the DOF-efficiency are explored through the comparative numerical experiments.