• Title/Summary/Keyword: damage imaging technique

Search Result 56, Processing Time 0.027 seconds

Estimation of evapotranspiration change due to the 2019 April Gangwon-do wildfire using remote-sensing data

  • Kim, JiHyun;Sohn, Soyoung;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.4-4
    • /
    • 2020
  • Three wildfires severely damaged local towns and forests in Gangwon-do, South Korea in 2019 April 4-5. Local hydrological regime could be greatly altered by the wildfires, therefore it is important to assess its damage (e.g. area and severity) and also resultant changes in hydrological fluxes. We retrieved the Normalized-Burned Ratio (NBR) index using remote-sensing data (Moderate Resolution Imaging Spectroradiometer (MODIS) 500-m 8-day surface reflectance data), and delineated the damaged-area based on the difference in the NBR (dNBR) before and after the wildfires. We then estimated changes in the annual evapotranspiration (AET) in 2019 using the MODIS evapotranspiration data (500-m 8-day). It was found that the damaged-area of the three wildfires was 29.50 km^2 in total, which take up 1.00-6.19% area of five catchments. It was estimated that the AET would be decreased as 0.05-1.56% over those five catchments, as compared to the pre-fire AET (2004-2018). The impact of the wildfires on the catchment AET was less severe than expected (i.e. up to 1.56%) mostly because two big wildfires were distributed across two catchments respectively (i.e. four catchments for the two wildfires) and the other wildfire was small and not severe. This study highlights the importance of assessing the area and severity of a wildfire when estimating its impact on the local hydrological cycle.

  • PDF

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

Cryo-SEM Methodology of Arabidopsis thaliana Stem Using High-Pressure Freezing (고압동결고정을 이용한 애기장대 줄기의 cryo-SEM 분석법)

  • Choi, Yun-Joung;Lee, Kyung-Hwan;Je, A-Reum;Chae, Hee-Su;Jang, Ji-Hoon;Lee, Eun-Ji;Kweon, Hee-Seok
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.111-114
    • /
    • 2012
  • The scanning electron microscopy is an ideal technique for examining plant surface at high resolution. Most hydrate samples, however, must be fix and dehydrate for observation in the scanning electron microscope. Because the microscopes operate under high vacuum, most specimens, especially biological samples, cannot withstand water removal by the vacuum system without morphological distortion. Cryo-techniques can observe in their original morphology and structure without various artifacts from conventional sample preparation. Rapid cooling is the method of choice for preparing plant samples for scanning electron microscopy in a defined physiological state. As one of cryo-technique, high-pressure freezing allows for fixation of native non-pretreated samples up to $200{\mu}M$ thick and 2 mm wide with minimal or no ice crystal damage for the freezing procedure. In this study, we could design to optimize structural preservation and imaging by comparing cryo-SEM and convention SEM preparation, and observe a fine, well preserved Arabidopsis stem's inner ultrastructure using HPF and cryo-SEM. These results would suggest a useful method of cryo-preparation and cryo-SEM for plant tissues, especially intratubule and vacuole rich structure.

Investigation of Ground Remote Sensing Technique Using CCD Camera (CCD 카메라를 이용한 지상원격탐사 기술 개발)

  • Kim, Eung Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.325-333
    • /
    • 2006
  • Recently, in the case of observing the global environment, satellite remote sensing technology has been important. It's because satellite remote sensing is valuable for assessing relatively large areas. But now, small scale remote sensing techniques are needed which can be applicable to the detail investigation of plant tree areas which afforest land after the large scale construction of roads, dams and airports. In this study, we tried to develop and propose a lower altitude sensing technique which can be used in ground remote sensing by using a CCD camera. As a result of this investigation the following can be concluded: We recognized the transference characteristics of filters which were used in comparative tests about the four ground remote sensing devices. We also found that the near-IR camera could be used for an imaging spectral radiometer in the extraction of the vegetation index. Furthermore, we found that the vegetation index has varied hour by hour during the day of the experiment. Finally, we brought about an increase phase of the NDVI in a forest fire, which caused considerable damage, by developing new ground remote sensing technology.

Technique for Malicious Code Detection using Stacked Convolution AutoEncoder (적층 콘볼루션 오토엔코더를 활용한 악성코드 탐지 기법)

  • Choi, Hyun-Woong;Heo, Junyoung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.39-44
    • /
    • 2020
  • Malicious codes cause damage to equipments while avoiding detection programs(vaccines). The reason why it is difficult to detect such these new malwares using the existing vaccines is that they use "signature-based" detection techniques. these techniques effectively detect already known malicious codes, however, they have problems about detecting new malicious codes. Therefore, most of vaccines have recognized these drawbacks and additionally make use of "heuristic" techniques. This paper proposes a technology to detecting unknown malicious code using deep learning. In addition, detecting malware skill using Supervisor Learning approach has a clear limitation. This is because, there are countless files that can be run on the devices. Thus, this paper utilizes Stacked Convolution AutoEncoder(SCAE) known as Semi-Supervisor Learning. To be specific, byte information of file was extracted, imaging was carried out, and these images were learned to model. Finally, Accuracy of 98.84% was achieved as a result of inferring unlearned malicious and non-malicious codes to the model.

Identification of the Nonrecurrent Laryngeal Nerve during Thyroid Surgery: Variations, Associated Vascular Malformation, Adequate Surgical Technique (갑상선 수술시 발견된 비회귀성 후두신경; 유형, 동반 혈관 이상, 신경 손상 예방에 대한 고찰)

  • Lee Jan-Dee;Yun Ji-Sup;Lim Chi-Young;Nam Kee-Hyun;Chang Hang-Seok;Chung Woong-Youn;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.1
    • /
    • pp.3-7
    • /
    • 2006
  • Purpose: The nonrecurrent laryngeal nerve(NRLN) is a rare anomaly that is associated with the developmentally aberrant subclavian artery. Although rare on the right side and exceptional on the left, an aberrant nonrecurrent pathway for RLN represents a major surgical risk. Three course variations of right NRLN can be distinguished: descending(type I) , horizontal(type II), ascending(type III). This study is performed to characterize the variations of NRLN, associated vascular anomaly, and proper surgical methods for preventing nerve damage. Materials and Methods: Between January 1998 and March 2006 3,381 thyroidectomy were performed at our institution, and during these operations a nonrecurrent laryngeal nerve was observed in 13 cases (0.38%). There were 1 men and 12 women with a median age of 48 years(range 28-57). All of them are identified on the right side. Results: In all cases, there were no clinical symptoms observed preoperatively. The nerve anomaly was diagnosed preoperatively in only one case. There were type I variations of right RLN in 2 cases and type II variations in 11 cases. The retroesophageal aberrant right subcalvian artery; no innominate(brachiocephalic) artery was found and the right common carotic artery was arising directly from the aortic arch, was seen in 12 cases. A vocal cord palaysis caused by NRLN damage during operation was observed in one patient(7.6%) , where the nerve was close to the superior thyroid artery. No other complications were noted. Conclusion: It can be possible to predict NRLN from signs associated with the vascular anomaly; clinical symptoms or imaging studies. When an vascular anomaly is not detected preoperatively, overlooking possibility of NRLN may lead to severe operative morbidity. Hence, It is most important to identify all the thyroid structures carefully during thyroid surgery and to be aware of the possibility of anatomic variations of RLN.

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Comparison and Analysis of Techniques for Achieving Azimuth Resolution of Imaging Radar (영상레이다의 방위 해상도 구현기법 비교 분석)

  • Hong, In-Pyo;kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.2
    • /
    • pp.185-196
    • /
    • 1997
  • By considering the definition and application of resolution as well as the concept and theory of SAR, the essential contents of the SAR design and analysis are described. This paper is to compare and analyze the resolution performance capability of three techniques for achieving azimuth resolution such as the real aperture, the unfocused and the focused techniques, through the simulation. Simulation is performed to make the restricted conditions for the unfocused technique that can be implemented by the less commputing load of signal processingand the lower cost. Through the mission analysis, the use of SAR image can be applied for estimation of whole situation at the regional area in the field of military demands for tactical purpose as well as civilian demands for the damage of disaster. RPV and sall or medium aircraft are selected to carry the SAR for these purposes and the proper resolution turns ou 5~15 m. The trade-off study of variables through the simulations results in the proper conditions such that range is less 3, 000 m, Wavelength is 1~10 m, and the raw signals and results processed by three techniques for two point targets are exhibited undr such conditions. Therefore, at some points, the result of this paper si proposed for useful applications of unforcused technique in the restricted conditions except the identification of the small target at a long range re- quired for high resolution.

  • PDF

A Study of Data Management Methods through Shake Correction of Underwater Investigation Using High Resolution Side Scan SONAR (흔들림 보정을 통한 고해상 사이드스캔소나의 데이터 관리기법 연구)

  • Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul;Choi, Sang-Sik;Lee, Heung-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.94-100
    • /
    • 2017
  • In the case of the side scan sonar operated by the towing method, the underwater structure electric jig was developed because there is a difficulty in the cross-sectional survey that the user wants when conducting the survey. However, in the case of the sound wave photographing method using the electric jig, since the boat and the sonar behaves as one body, data distortion has occurred due to various problems according to working environment, such as, the rolling phenomenon of the boat due to the wave and the fluctuation of the sonic image due to the inoperability of the boat driver. Therefore, in order to solve the image blurring caused by the operation of the equipment for underwater survey of the existing side scan sonar, in this research, the program was supplemented to enable the shake correction by attaching the shake correction sensor and developing the shake correction algorithm. In order to verify the improvement of the sonar data resolution, the sonic images before and after the shake correction were collected through on-site investigation and the analysis of the sonic image data acquired by a diver measuring the actual damage length and depth. This study is expected to contribute to the development of sonar imaging technique of the underwater surface of the structure and bed surface of the sea or a river using the side scan sonar in the future.

Microvascular Contrast Image in Portal Veins of Rat using Micro-CT (마이크로 CT를 이용한 BALB/C(흰쥐) 간문맥의 미세혈관 조영 영상)

  • Lee, Sang-Ho;Lim, Cheong-Hwan;Jung, Hong-Rayng;Han, Beom-Hee;Mo, Eun-Hee;Chai, Kyu-Yun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.259-266
    • /
    • 2010
  • The study focuses on the value of Micro CT, a high resolution X-ray imaging device, by using it on rats to observe the overall portal vein image of the liver and the microvasculature of each lobes, visualize the 4 segmental lobes and acquire 3D image of the microvasculature through the reconstruction of sectional image data. Less of the damage to liver of the 5 mice, the device was able to separate the liver into 4 segmental lobes and displayed the 4 portal vein microvasculature in 2D. By using the 3D MIP technique, observation of the whole portal vein system microvasculature in 3D image was made possible along with each of the portal vein segment's branches until the 6th branch. Measured the size of 6branch, the average was measured at 1branch : $0.51mm{\pm}0.08$, 2 branch : $0.32mm{\pm}0.12$, 3 branch : $0.23mm{\pm}0.11$, 4 branch : $0.19mm{\pm}0.08$, 5 branch : $0.13mm{\pm}0.06$, 6 branch : $70.5{\mu}m{\pm}14.1$. The 3D image and the images of the microvasculatures in the result of study proved that the Micro-CT can be considered many useful device in obtaining high resolution images.