• Title/Summary/Keyword: damage aspect

Search Result 306, Processing Time 0.025 seconds

An Evaluation on the Chloride Resistance of Concrete Footing at Coastal Area -Comparision of Performance in Korea Building Code(KBC)- (해안인접지역 기초 구조물콘크리트의 내염해 성능 평가 -건축구조기준과의 성능비교-)

  • Park, Yong-Kyu;Yoon, Gi-Won;Kim, Hyun-Woo;Kim, Yong-Ro;Song, Young-Chan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.148-149
    • /
    • 2016
  • In this paper, the increase in chloride resistance of footing concrete at coastal area was evaluated by replacement of Mineral Admixture. In KBC 2009, the footing concrete's minimum specific concrete strength at coastal area is determined to 35MPa. However, this is criteria only based on the strength aspect. Thus, it is not considered to increase the chloride resistance by replacement of Mineral Admixture. According to the test results of chloride ions penetration resistance, 35MPa class concrete with OPC 100% shown inaccessible state. Low-strength (24~30MPa class) concretes with Mineral Admixture, however, presented better performances. In addition, chloride diffusion coefficient tests showed identical appearance. Therefore, the current KBC's chloride resistance criteria based on only concrete strength has to review for the reason it can cause many problems (ex. cost increases by growing concrete strength and the environmental issues by a lot of cement use).

  • PDF

A Study on the Measurement of Damages under Int'l Sale Contract of Goods (국제물품매매계약하(國際物品賣買契約下)의 손해배상금(損害賠償金) 산정(算定)에 관한 연구(硏究))

  • Oh, Se-Chang
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.17
    • /
    • pp.37-69
    • /
    • 2002
  • This study sumed up general rules for measuring damages based on SGA, UCC, CISG, PICC legislated by on the base of English decision of Hadley v. Baxendale Concluding marks as follows : (1) General rule for measuring damages is a standard rule that is developed to place the aggrieved party in as good a position as if the party in breach performed the contract. (2) Damages may also be accompanied by other remedies (3) Damages has alternative character (4) Damages give the aggrieved party full compensation (5) It is enough for the aggrieved party simply to prove the non-performance for damages (6) Occurence of harm must be reasonably certain and a direct consequence of non-performance (7) while Rule for measuring damages an UCC is concrete CISG is comprehensive. (8) Although rule of UCC and CISG for damages measurement is a similar in many aspect but there are in expression and range of damage between them. (9) the result of this study will give researchers the opportunity to develope in depth and their report of research also contribute chance to perform business their effective oversea's trade

  • PDF

Development of a Transmission Error Measurement System and Its Adaptation to a Manufacturing Line (기어 전달오차 측정 시스템의 개발 및 라인 적용에 관한 연구)

  • Lee, Hyun Ku;Lee, Sang Hwa;Ku, Han Il;Yoo, Dong Kyu;Won, Kwang Min;Lee, Tae Hwi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.420-427
    • /
    • 2016
  • Diverse research on gearing systems have been made to resolve gear NVH problems for many decades, and transmission error (T.E.) has been identified as one of the main sources generating gear noises. While gear profiles and amounts of tooth modifications have influences on gear noise in the design aspect, it is found that bad manufacturing conditions such as burrs, bumps and damage, which result in improper gear operating conditions, produce gear noise with respect to manufacturing process. In this paper, T.E. measurement system was introduced to examine the gears damaged or improperly manufactured, while they are assembled, by comparing T.E. values and various gear conditions with theoretical ones. This T.E. measurement system, following grinding machining process, has been installed in a manufacturing line in 2014, and it results that the transmission rework to resolve manufacturing problems is not needed at the end of line.

Study on the characteristics of acid resistance and thermal shock for epoxy coatings (에폭시계 코팅재의 내산열충격 특성에 관한 연구)

  • Lee, Sang-Yeal;Yun, Byoung-Du
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.4
    • /
    • pp.362-369
    • /
    • 2007
  • This paper was studied on the characteristics of acid resistance and thermal shock for epoxy coatings in the strong acidic environment. The exhaust gas system, such as a air preheater, desulfurization equipment, for industrial boiler is damaged by dew point corrosion. To protect the acid corrosion, the coating using nonmetal was applied. The electrochemical polarization test, acid resistance and thermal shock test for epoxy coatings were carried out. And the acid resistance and thermal shock characteristics, aspect, and electrochemical anti-corrosion characteristics for epoxy coatings in the strong acidic environment were considered. The main results are as followings: As the epoxy glass flake coating by acidic thermal shock was damaged to the crack, blistering and elution etc., the current density of epoxy glass flake coating is high. But the damage of epoxy metal complex coating by acidic thermal shock was not occurred. Therefore the characteristics of acid resistance and thermal shock for epoxy metal complex coating is better than those for epoxy glass flake coating.

A Study on the Application of Vertical Drainage System for Resisting Uplift of Sub-structure (지하구조물 부력방지를 위한 연직배수시스템의 적용성 연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.183-190
    • /
    • 2001
  • A sub-structure is uplift if the floating greater than dead load of a structure. When such occasion arise, a structure sustain damage. In general, the measures for floating prevention of structure are a permanent anchor method and a drainage method. The primary construction cost of a permanent anchor method is heavy. And a drainage method is needed maintenance management long term. At this point, the measures for floating prevention of a notion being requires the other days. Therefore, at this study a simple construction and a economic vertical drainage system was developed. The findings be used in the in-situ and gave careful consideration to an application. The result of examination, this system considering a characteristic of coefficient of permeability for the ground controls occurrence of floating despite the water level rise of the ground, which a period of construction get shorter compared with other methods, which understood that measures satisfactory in the financial aspect. Especially, A structure occurring effects of flatting under the course of construction made use of it. As the result of the effect of it was confirmed by construction.

  • PDF

Numerical analyses for the structural assessment of steel buildings under explosions

  • Olmati, Pierluigi;Petrini, Francesco;Bontempi, Franco
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.803-819
    • /
    • 2013
  • This paper addresses two main issues relevant to the structural assessment of buildings subjected to explosions. The first issue regards the robustness evaluation of steel frame structures: a procedure is provided for computing "robustness curves" and it is applied to a 20-storey steel frame building, describing the residual strength of the (blast) damaged structure under different local damage levels. The second issue regards the precise evaluation of blast pressures acting on structural elements using Computational Fluid Dynamic (CFD) techniques. This last aspect is treated with particular reference to gas explosions, focusing on some critical parameters (room congestion, failure of non-structural walls and ignition point location) which influence the development of the explosion. From the analyses, it can be deduced that, at least for the examined cases, the obtained robustness curves provide a suitable tool that can be used for risk management and assessment purposes. Moreover, the variation of relevant CFD analysis outcomes (e.g., pressure) due to the variation of the analysis parameters is found to be significant.

Static and fatigue performance of stud shear connector in steel fiber reinforced concrete

  • Xu, Chen;Su, Qingtian;Masuya, Hiroshi
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.467-479
    • /
    • 2017
  • The stud is one of the most frequently used shear connectors which are important to the steel-concrete composite action. The static and fatigue behavior of stud in the steel fiber reinforced concrete (SFRC) were particularly concerned in this study through the push-out tests and analysis. It was for the purpose of investigating and explaining a tendency proposed by the current existing researches that the SFRC may ameliorate the shear connector's mechanical performance, and thus contributing to the corresponding design practice. There were 20 test specimens in the tests and 8 models in the analysis. According to the test and analysis results, the SFRC had an obvious effect of restraining the concrete damage and improving the stud static performance when the compressive strength of the host concrete was relatively low. As to the fatigue aspect, the steel fibers in concrete also tended to improve the stud fatigue life, and the favorable tensile performance of SFRC may be the main reason. But such effect was found to vary with the fatigue load range. Moreover, the static and fatigue test results were compared with several design codes. Particularly, the fatigue life estimation of Eurocode 4 appeared to be less conservative than that of AASHTO, and to have higher safety redundancy than that of JSCE hybrid structure guideline.

Design Study of LAR Tokamak Reactor with a Self-consistent System Analysis Code

  • Hong, B.G.;Lee, D.W.;Kim, S.K.;Kim, D.H.;Lee, Y.O.;Hwang, Y.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.314-314
    • /
    • 2010
  • The design of the blanket and shield play a key role in determining the size of a reactor since it has an impact on the various reactor components. The blanket should produce enough tritium for tritium self-sufficiency and the shield should provide sufficient protection for the superconducting TF coil. Neutronic optimization of the blanket and the shield is necessary, and we coupled the system analysis with a neutronic calculation to account for the interrelation of the blanket and shield with the plasma performance of a reactor system in a self-consistent manner. By using the coupled system analysis code, the operational space for a low aspect ratio (LAR) tokamak reactor with a superconducting toroidal field (TF) coil is investigated with an spect ratio in the range of 1.5 - 2.5. The minimum major radius which satisfies all the physics and engineering requirements increases with the magnetic field at the magnetic axis. A required inboard shield thickness is mainly determined by the requirement on the protection of the TF coil against radiation damage. It is shown that to have a fusion power bigger than 3,000 MW in the LAR tokamak with a superconducting TF coil, a major radius bigger than 4.0 m is required.

  • PDF

Production Practices for North American Ginseng: Challenges and Opportunities

  • Proctor John T.A.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.212-226
    • /
    • 2002
  • North American ginseng production may have been maximized in the traditional growing areas in the last decade and further increases may be in woods grown root, for niche markets. The marketplace demands high quality roots. Most problems leading to low quality roots start with the grower and can be avoided. These include poor site selection, inadequate soil drainage, untimely and poorly applied pesticides, and neglect of good sanitary practices. Selection of low lying sites increased the plant damage from frost in Ontario in May 2002. Seeding is still the major method of propagation of ginseng in spite of some success in culturing different parts of the plant. Opportunities exist for shortening the stratification period of North American ginseng seed to allow spring planting. This may reduce disease incidence. Since only one-third of ginseng seed sown ultimately produces plants harvested after 3 years any approach that reduces disease incidence and improves seed germination, seedling emergence and crop stand must be pursued. Disease is the major problem in ginseng cutivation from seed stratification, soil preparation prior to planting, right through to drying of the roots. Replant disease remains as an unresolved problem and needs full characterization and new approaches for control. Much progress has been made in research and related extension activities in disease control although challenges will arise such as with Quintozene and its replacement with Quadris for control of diseases caused by Rhizoctonia. Decreased labor populations and increased associated costs for ginseng production are causing rapid mechanization in every aspect of the ginseng industry. Engineers, machinery dealers, and fabricators, and growers are being challenged to increase efficiency by mechanization.

  • PDF

The Expression of ECP in the Perennial Allergic Rhinitis and Correlations with Mucociliary Clearance (통년성 알레르기성 비염에서의 ECP의 발현양상과 점액섬모수송기간과의 관계)

  • 오승철;김찬우;이상학
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.85-90
    • /
    • 1998
  • The role of the ECP(Eosinophilic cationic protein) is still unknown in the allergic rhinitis. In bronchial asthma, ECP can induce the exposure of the neuropeptidergic nerve to environments destroying the bronchial mucosa, aggravating the bronchial hypersensitivity and delay the mucociliary clearance. In the clinical aspect, we can (md that patients with perennial allergic rhinitis sometimes have sinusitis. The purpose of this article is to evaluate whether mucosal damage by ECP can play a role to develop the sinusitis by delaying the mucociliary clearance, and relationship between long symptom duration of allergic rhinitis and mucociliary clearance. In 32 perennial allergic rhinitis patients, we elucidated there is correlation among ECP presence, mucociliary clearance, sinusitis, and symptom durations. The obtained results were as follows : 1. ECP appeared in all mucosa of each specimen. 2. Mean mucociliary clearance time is 6 mins. 12 sec. in allergic patients with sinusitis, 6 mins. 36 sec in allergic patients without sinusitis. 3. n out of 32 cases have mucosal destruction. 4. Symptom duration is not correlated with the development of sinusitis. This study suggests that ECP may destroy the mucosa in allergic rhinitis and the mucociliary clearance of allergic rhinitis is not related to sinusitis and symptom dotation. Therefore development of sinusitis in allergic rhinitis seems not to be caused by delaying of mucociliary clearance due to mucosal destruction, but by some other factors.

  • PDF