• Title/Summary/Keyword: damage analysis

Search Result 7,712, Processing Time 0.033 seconds

Behaviour of GFRP composite plate under ballistic impact: experimental and FE analyses

  • Ansari, Md. Muslim;Chakrabarti, Anupam
    • Structural Engineering and Mechanics
    • /
    • v.60 no.5
    • /
    • pp.829-849
    • /
    • 2016
  • In this paper, experimental as well as numerical analysis of Glass Fiber Reinforced Polymer (GFRP) laminated composite has been presented under ballistic impact with varying projectile nose shapes (conical, ogival and spherical) and incidence velocities. The experimental impact tests on GFRP composite plate reinforced with woven glass fiber ($0^{\circ}/90^{\circ}$)s are performed by using pneumatic gun. A three dimensional finite element model is developed in AUTODYN hydro code to validate the experimental results and to study the ballistic perforation characteristic of the target with different parametric variations. The influence of projectile nose shapes, plate thickness and incidence velocity on the variation of residual velocity, ballistic limit, contact force-time histories, energy absorption, damage pattern and damage area in the composite target have been studied. The material characterization of GFRP composite is carried out as required for the progressive damage analysis of composite. The numerical results from the present FE model in terms of residual velocity, absorbed energy, damage pattern and damage area are having close agreement with the results from the experimental impact tests.

Typhoon Path and Prediction Model Development for Building Damage Ratio Using Multiple Regression Analysis (태풍타입별 피해 분석 및 다중회귀분석을 활용한 태풍피해예측모델 개발 연구)

  • Yang, Seong-Pil;Son, Kiyoung;Lee, Kyoung-Hun;Kim, Ji-Myong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.437-445
    • /
    • 2016
  • Since typhoon is a critical meteorological disaster, some advanced countries have developed typhoon damage prediction models. However, although South Korea is vulnerable to typhoons, there is still shortage of study in typhoon damage prediction model reflecting the vulnerability of domestic building and features of disaster. Moreover, many studies have been only focused on the characteristics and typhoon and regional characteristics without various influencing factors. Therefore, the objective of this study is to analyze typhoon damage by path and develop to prediction model for building damage ratio by using multiple regression analysis. This study classifies the building damages by typhoon paths to identify influencing factors then the correlation analysis is conducted between building damage ratio and their factors. In addition, a multiple regression analysis is applied to develop a typhoon damage prediction model. Four categories; typhoon information, geography, construction environment, and socio-economy, are used as the independent variables. The results of this study will be used as fundamental material for the typhoon damage prediction model development of South Korea.

Bree's interaction diagram of beams with considering creep and ductile damage

  • Nayebi, A.
    • Structural Engineering and Mechanics
    • /
    • v.30 no.6
    • /
    • pp.665-678
    • /
    • 2008
  • The beams components subjected to the loading such as axial, bending and cyclic thermal loads were studied in this research. The used constitutive equations are those of elasto-plasticity coupled to ductile and/or creep damage. The nonlinear kinematic hardening behavior was considered in elastoplasticity modeling. The unified damage law proposed for ductile failure and fatigue by the author of Sermage et al. (2000) and Kachanov's creep damage model applied to cyclic creep and low cycle fatigue of beams. Based on the results of the analysis, the shakedown limit loads were determined through the calculation of the residual strains developed in the beam analysis. The iterative technique determines the shakedown limit load in an iterative manner by performing a series of full coupled elastic-plastic and continuum damage cyclic loading modeling. The maximum load carrying capacity of the beam can withstand, were determined and imposed on the Bree's interaction diagram. Comparison between the shakedown diagrams generated by or without creep and/or ductile damage for the loading patterns was presented.

Damage detection of railway bridges using operational vibration data: theory and experimental verifications

  • Azim, Md Riasat;Zhang, Haiyang;Gul, Mustafa
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.2
    • /
    • pp.149-166
    • /
    • 2020
  • This paper presents the results of an experimental investigation on a vibration-based damage identification framework for a steel girder type and a truss bridge based on acceleration responses to operational loading. The method relies on sensor clustering-based time-series analysis of the operational acceleration response of the bridge to the passage of a moving vehicle. The results are presented in terms of Damage Features from each sensor, which are obtained by comparing the actual acceleration response from the sensors to the predicted response from the time-series model. The damage in the bridge is detected by observing the change in damage features of the bridge as structural changes occur in the bridge. The relative severity of the damage can also be quantitatively assessed by observing the magnitude of the changes in the damage features. The experimental results show the potential usefulness of the proposed method for future applications on condition assessment of real-life bridge infrastructures.

An Analysis of the Damage Factor Vulnerability Using a Natural Disaster DB (자연재해 DB를 이용한 피해항목별 취약성 분석)

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyo-Jin
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.505-508
    • /
    • 2008
  • When it grasps a total property losses and relationship of damage factors, there is possibility of reducing the natural disaster damage which is a yearly repeated. Also, checking and supply to vulnerability should be presupposed. This study aims to find out a damage factor vulnerability using a natural disaster database by Park et al(2007). And added 2005 year data to database. Total 10 damage factors are deaths(person, including missing person) injury(person), victims(person), building(thousand), vessel(thousand), cultivated land(thousand), public facilities(thousand), others(thousand), total property losses(thousand). We analyzed of correlation analysis, ratio, population, area, regional character etc for damage factors.

  • PDF

Study on The Damage Location Detection of Shear Building Structures Using The Degradation Ratio of Story Stiffness (층강성 손상비를 이용한 전단형 건물의 손상위치 추정에 관한 연구)

  • Yoo, Seok-Hyung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.3-10
    • /
    • 2018
  • Damage location and extent of structure could be detected by the inverse analysis on dynamic response properties such as frequencies and mode shapes. In practice the measured difference of natural frequencies represent the stiffness change reliably, however the measured mode shape is insensitive for stiffness change, but provides spatial information of damage. The damage detection index on shear building structures is formulated in this study. The damage detection index could be estimated from mode shape and srory stiffness of undamaged structure and frequency difference between undamaged and damaged structure. For the verification of the observed damage detection method, the numerical analysis of Matlab and MIDAS and shacking table test were performed. In results, the damage index of damaged story was estimated so higher than undamaged stories that indicates the damaged story apparently.

Application of Multi-Dimensional Flood Damage Analysis for Urban Flood Damage (다차원 홍수피해산정방법을 이용한 도시지역의 홍수피해액 산정)

  • Lee, Keon Haeng;Choi, Seung An;Kim, Hung Soo;Shim, Myung Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4B
    • /
    • pp.363-369
    • /
    • 2006
  • A simple and an improved methods for the economic analysis of the flood control project has been in previous studies in Korea. In 2004, the Multi-Dimensional Flood Damage Analysis (MD-FDA) was developed and now it is widely used for the economic analysis of flood control project. However, the MD-FDA was developed for general damage assessment and analysis without consideration of specific regional characteristics such as urban and rural areas. To compensate the MD-FDA for the application in urban area, a part of damage estimation components is modified and a component for the flood damage estimation is suggested. The component we suggest is for the consideration of the capability of stormwater pump stations in the study area. When flood is occurred in the urban area, the damage potential is larger than the rural area because of the concentration of human lives and properties. So, many stormwater pump stations are located in the urban area and the inundation depth is estimated by considering the capabilities of pump stations. We also compensate the damage components such as the damages of industrial area, and public facilities for the flood damage estimation of the urban area. The results by the compensated MD-FDA for the urban area application with those by original MD-FDA are compared. As a result the B/C ratio showed 6.75 and 5.51 respectively for the modified and original MD-FDA. This difference might be largely affected by the damage rate of the public facilities.

Experimental Modal Analysis for Damage Identification in Foundation-Structure Interface of Caisson-type Breakwater (케이슨식 방파제 지반-구조 경계부 손상식별을 위한 실험적 모드분석)

  • Lee, So-Young;Lee, So-Ra;Kim, Jeong-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • This paper presents an experimental modal analysis of a caisson-type breakwater to produce basic information for the structural health assessment of a caisson structure. To achieve the objective, the following approaches are implemented. First, modal analysis methods are selected to examine the modal characteristics of a caisson structure. Second, experimental modal analyses are performed using finite element analyses and lab-scale model tests. Third, damage scenarios that include several damage levels in a foundation-structure interface are designed. Finally, the effects of damage on the modal characteristics are analyzed for the purpose of utilizing them for damage identification.

Structural Durability Analysis of Tie Rod (타이로드의 구조적 내구성 해석)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.68-75
    • /
    • 2012
  • This study aims at the structural analysis of vibration and fatigue according to the tie rod configuration. The maximum displacement amplitude is happened at 156Hz by harmonic vibration analysis, this tie rod model can be broken as the weakest state. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sine wave' becomes most stable. In case of 'Sine wave' with the average stress of 0MPa and the amplitude stress of 570MPa, the possibility of maximum damage becomes 70%. This stress state can be shown with 140 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively utilized with the design on tie rod by investigating prevention and durability against its damage.

Damage Pattern Analysis of Voltage Cabinet Panel due to Flame (분전반의 화염에 의한 소손패턴 분석)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Kim, Man-Geon
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 2008
  • This paper deals with damage patterns of cabinet panel for low voltage deteriorated by flame. In order to analyze damage patterns, we used Metallurgical Microscope, x-ray system, and Fourier Transform Infrared spectroscopy. Firstly, Metallurgical microscope was used for analysis of electrical causes, such as electric short and overload Secondly, X-ray system was used for analysis of internal characteristics of circuit breakers. Lastly, Fourier Transform Infrared spectroscopy was used for analysis of damage direction by flame.

  • PDF