• 제목/요약/키워드: dMLC(dynamic multi-leaf collimator)

검색결과 5건 처리시간 0.021초

Practical Virtual Compensator Design with Dynamic Multi-Leaf Collimator(dMLC) from Iso-Dose Distribution

  • Song, Ju-Young;Suh, Tae-Suk;Lee, Hyung-Koo;Choe, Bo-Young;Ahn, Seung-Do;Park, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Yi, Byong-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.129-132
    • /
    • 2002
  • The practical virtual compensator, which uses a dynamic multi-leaf collimator (dMLC) and three-dimensional radiation therapy planning (3D RTP) system, was designed. And the feasibility study of the virtual compensator was done to verify that the virtual compensator acts a role as the replacement of the physical compensator. Design procedure consists of three steps. The first step is to generate the isodose distributions from the 3D RTP system (Render Plan, Elekta). Then isodose line pattern was used as the compensator pattern. Pre-determined compensating ratio was applied to generate the fluence map for the compensator design. The second step is to generate the leaf sequence file with Ma's algorithm in the respect of optimum MU-efficiency. All the procedure was done with home-made software. The last step is the QA procedure which performs the comparison of the dose distributions which are produced from the irradiation with the virtual compensator and from the calculation by 3D RTP. In this study, a phantom was fabricated for the verification of properness of the designed compensator. It is consisted of the styrofoam part which mimics irregular shaped contour or the missing tissues and the mini water phantom. Inhomogeneous dose distribution due to the styrofoam missing tissue could be calculated with the RTP system. The film dosimetry in the phantom with and without the compensator showed significant improvement of the dose distributions. The virtual compensator designed in this study was proved to be a replacement of the physical compensator in the practical point of view.

  • PDF

동적 다엽콜리메이터를 이용한 척수의 부분 차폐 기법 (Spinal Cord Partial Block Technique Using Dynamic MLC)

  • 조삼주;이병용;이상욱;안승도;김종훈;권수일;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2003
  • 두경부 및 흥부에서 척수 견딤선량은 방사선 치료 제약 조건중의 하나이다. 이 영역에서 척수 견딤 선량을 임상적으로 허용 가능한 수준으로 유지하면서 표적에 임상적으로 유의한 선량을 전달하는 것은 쉽지 않은 문제이다. 기존의 치료 방법을 적용할 때 따르는 문제를 해결하기 위해 동적 다엽콜리메이터(dynamic multi leaf collimator, dMLC)를 사용한 척수의 부분 차폐 기법(spial cord partial block technique)을 개발하였다. 이 기법은 기존의 3차원 방사선 치료 계획 장치를 사용하여 치료계획을 수립한다. 치료 계획 절차는 표적을 잘 포함 할 수 있는 빔 방향 및 빔 개수를 설정한 후, 척수 등 방사선 민감 장기를 보호하기 위한 부분차폐를 적용하여 최적화된 선량분포를 만들어 낸다. 이 기법의 유용성을 평가하기 위해 동일한 환자에 대해 기존의 치료 계획과 PBT 치료 계획을 수립하여 상호 비교 평가하였다. 평균 선량과 DVH를 치료 계획 평가 인자로 사용하였다. 임상 적용 가능성을 위해 일련의 정도관리를 수행하여 평가하였다. 이 정도관리는 선량 분포 검증에 대한 필름 도시메트리와 단일점 측정으로 구성되어 있다. PBT 치료계획이 기존의 치료계획 보다 좋은 결과를 얻을 수 있었으며, 두경부에서 유용한 치료 기법임을 볼 수 있었다.

  • PDF

Spinal Cord Partial Block Technique Using Dynamic MLC

  • Cho, Sam-Ju;Yi, Byong-Yong;Back, Geum-Mun;Lee, Sang wook;Ahn, Seung-Do;Kim, Jong-Hoon;Kwon, Soo-Il;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.138-140
    • /
    • 2002
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck (H&N) or the thorax region. Due to the fact that the cord is the elongated shaped structure, it is not an easy task to maintain the cord dose within the clinically acceptable dose range. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. Three dimension (3D) conformal beam directions, which minimize the coverage of the normal organs such as the lung and the parotid gland, were chosen. The PBT field shape for each field was designed to shield the spinal cord with the dMLC. The transmission factors were determined by the forward calculation method. The plan comparisons between the conventional 3D conformal therapy plan and the PTB plan were performed to evaluate the validity of this technique. The conformity index (CI) and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan always generated better results than the conventional 3D conformal plan. The PBT was proved to be useful for the H&N and thorax region.

  • PDF

두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰 (The usefulness of Forward IMRT for Head and Neck Cancer)

  • 백금문;김대섭;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.41-52
    • /
    • 2003
  • I. 목적 방사선 치료계획에 있어서 정상조직의 선량과 치료부위 선량의 분포는 매우 중요하다. 또한 치료부위의 균일한 선량분포를 얻기 위하여 여러 가지 방법을 이용하고 있다. 특히 두경부(Head & Neck) 종양의 방사선 치료 시 체표 윤곽의 변화가 심하여 이에 따른 선량 불균일 보정이 필요하다. 기존의 치료방법으로는 parotid gland 와 spinal cord 의 tolerance dose 이하를 유지하면서 planning target volume(PTV)에 충분한 치료 선량을 전달하기에는 여러 가지 어려움이 있다. 이에 본원에서는 Forward IMRT를 이용한 방사선 치료의 유용성 및 실용적인 정도관리 방법에 관한 연구를 하였다. II. 대상 및 방법 본 연구는 두경부(Head & Neck) 종양 비인두암(nasophrygeal cancer)의 방사선 치료가 요구되는 환자를 대상으로 하여 2차원적인 치료계획과 dynamic Mulit-Leaf Collimator(dMLC)를 이용하여 partial block technique(PBT)방법을 적용한 Forward IMRT를 위한 치료계획을 dose volume histogram(DVH)로 비교 분석하였다. 또한 정도관리(quality assurance, QA)를 위하여 필름과 pinpoint chamber를 이용하여 정확한 선량 평가를 실시하였다. III. 결과 2차원적인 치료계획과 Forward IMRT를 적용한 치료계획의 DVH를 비교 분석한 결과 Forward IMRT를 적용한 치료계획이 Rt, Lt parotid gland와 spinal cord에 들어가는 선량을 좀더 줄일 수 있었다. 이러한 Forward IMRT의 시도로 조사면의 방사선 세기가 정상조직의 보호를 개선시키고 치료의 최적화를 이룰 수 있었다. Inverse IMRT에 비해 기존의 3차원적 치료계획 장치를 이용할 수 있고 비교적 단순한 방사선 세기 패턴이므로 정도관리가 용이하였다. IV. 결론 Forward IMRT는 2차원적인 치료법에 비하여 PTV에는 균일한 선량분포를 이루면서 정상조직에는 tolerance dose 이하로 선량을 전달 할 수 있는 치료기법이었다.

  • PDF

다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가 (Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator)

  • 이순성;최상현;민철기;김우철;지영훈;박승우;정해조;김미숙;유형준;김금배
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.168-177
    • /
    • 2015
  • 세기조절방사선치료(IMRT)는 복잡하고 정교한 방사선치료 기법을 이용한 환자 치료 시 치료계획의 정확성을 평가하기 위해 첫 치료 시작 전 품질관리를 권고하고 있다. 이 목적 실현을 위해 최근 상용화된 품질관리 소프트웨어를 이용하면 치료 전후의 정확한 방사선량의 전달을 확인할 수 있다. 이에 본 연구에서는 품질관리 시스템 내에 MLC의 선량학적엽간격(DLG)의 변화에 따른 IMRT 치료계획 경우별 계산 결과의 분석을 통해 그 효용성을 평가하고자 한다. MobiusFx에 입력할 MLC 다이나로그 파일(Dynamic MLC Log File)을 획득하기 위하여 HD120 MLC가 장착된 Novalis Tx를 이용하였다. IMRT 치료계획을 수립하기 위해 Eclipse 치료계획시스템을 사용하였으며, IBA사의 I'mRT 팬톰영상에 표적 및 장기 윤곽(다중표적, 전립선, 두경부, C-모양)을 묘사하였다. DLG에 따른 선량분포의 변화를 확인하기 위해서 MLC 다이나로그 파일을 MobiusFX 시스템에 입력하고 각 경우마다 0.5, 0.7, 1.0, 1.3, 1.6 mm로 DLG를 변화시켜 선량계산의 차이를 평가하였다. 선량평가는 허용범위가 3%/3 mm인 3차원 감마지표의 통과율과 DVH 그리고 CC13 전리함에 대한 점선량을 통해 분석하였다. MobiusFx에서 4가지의 경우에 대해 각 DLG 마다의 선량분포를 비교 분석한 결과, 다중표적과 두경부는 DLG가 0.5와 0.7 mm에서 3~5%, 1.0~1.6 mm에서 3% 미만의 선량차이를 보였다. 감마 지수 통과율에서도 0.7 mm 이하의 DLG에서 다중표적 경우의 중앙표적과 상위표적은 30% 미만, PTV와 척수는 81% 미만이었으며, 다른 DLG에서는 95% 이상의 통과율을 보였다. 하위표적과 귀밑샘은 모든 DLG에서 100.0%이었다. 전립선에서 점선량은 모든 DLG에서 3% 미만의 차이를 보였으나 PTV에서 DLG 0.7 mm 이하와 1.0 mm 이상에서는 각각 95% 미만과 98% 이상의 통과율을 보였다. 직장과 방광은 모든 DLG에서 100.0%로 나타났다. C-모양에서 점선량은 1.3 mm를 제외한 모든 DLG에서 3~9%의 차이를 보이며 PTV는 1.0과 1.3 mm의 DLG에서 각각 96.7, 93.0%의 통과율을 보였으나 다른 DLG에서는 86% 미만이었다. 코어에서는 모든 DLG에서 100.0%였다. 본 연구에서는 치료계획 품질관리 시스템에서 DLG 적용 값의 차이에 따라 품질관리의 정확성에 유의미한 영향을 미치는 것으로 확인되었다. 그러므로 IMRT, VMAT 등 MLC의 움직임을 이용한 방사선치료법의 경우 정확한 품질관리를 위해서는 사용하고 있는 치료장비 및 치료계획시스템에 맞는 적합한 DLG 값을 상호 일치시켜 사용해야 할 것으로 판단된다.