• Title/Summary/Keyword: d-ROM

Search Result 190, Processing Time 0.025 seconds

Effects of Limited Dorsiflexion Range of Motion on Movement Strategies during Landing (발등굽힘 관절가동범위 제한이 착지 시 움직임 전략에 미치는 영향)

  • Inje Lee;Donggun Kim;Hyeondeukje Kim;Hyunsol Shin;Jiwon Lee;Yujin Jang;Myeongwoo Pi
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.147-154
    • /
    • 2023
  • Objective: This study aimed 1) to compare the Landing Error Scoring System (LESS) score and movement patterns during landing of the lesser dorsiflexion range of motion (LDFROM) group to that with the greater dorsiflexion range of motion group, and 2) to identify the correlation between the weight-bearing dorsiflexion range of motion (WBDF ROM), LESS score, and movement patterns during landing. Method: Fifty health adults participated in this study. WBDF ROM was measured using the weight bearing lunge test while movement patterns during landing was assessed using the LESS. The joint angles of the ankle, knee and hip joints during landing were analyzed using the 2D video analysis. After mean value of WBDF ROM was calculated, participants were divided into two groups (GDFROM and LDFROM) based on the mean value. The Mann-Whiteny 𝒰 test was used to identify differences in movement strategies during landing between two groups and the Pearson's correlation analysis was performed to determine relationships between WBDF ROM and movement strategies. Results: The LDFROM group showed the poorer LESS score and stiffer landing kinematics during landing compared to the GDFROM group (p<0.05). In addition, DFROM was significantly related to the LESS score and landing kinematics (p<0.05) except for total hip excursion (p=0.228). Conclusion: Our main findings showed that the LDFROM group had poorer landing quality and stiffer landing movements compared to the GDFROM group. In addition, increase of WBDF ROM significantly improved landing quality and soft-landing movements. To reduce shock during landing such as ground reaction forces, individuals need to better utilize WBDF ROM and lower extremity movements based on our findings. Therefore, intervention programs for safer landings should include exercises that increase WBDF ROM and utilize eccentric contraction.

Three cases meniscus injury treated with Shinbaro pharmacopuncture therapy

  • Lee, So Jin;Yoon, Tae Kyung;Shin, Soo Ji;Ahn, Sang Min;Lee, Seong Jin;Won, Jeong Yoon;Jang, Yeo Jin
    • Journal of Acupuncture Research
    • /
    • v.34 no.3
    • /
    • pp.109-119
    • /
    • 2017
  • Objectives : The purpose of this report was to show that oriental therapy, specifically Shinbaro pharmacopuncture is effective for improvement of symptoms and and range of motion (ROM) in patients diagnosed with meniscus tears in the knee. Methods : Three patients were treated with herbal medicine, acupuncture, cupping, Shinbaro pharmacopuncture. The efficacies of the treatments in the three cases were assessed and the progress of the three cases were measured Numerical Rating Scale (NRS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), European Quality of Life five dimensions dimensions (EQ-5D), and range of motion (ROM) measurements. Results : After all the treatments, NRS, WOMAC, and EQ-5D decreased. Active and passive ROM of the knee increased. Conclusion : These reports show the effect of Shinbaro pharmacopucture on a meniscus tear. Due to the small number of cases in this study, further case reports are needed.

Joint Range Measurement and Correction using Kinect Camera (키넥트 카메라를 이용한 관절 가동 범위 측정과 보정)

  • Jeong, Juheon;Yoon, Myeongsuk;Kim, Sangjoon;Park, Gooman
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.11a
    • /
    • pp.63-66
    • /
    • 2019
  • 가상현실과 증강현실의 대중화로 사람의 동작을 실시간 3D 애니메이션으로 구현하는 연구가 활발히 진행 중이다. 특히 Microsoft에서 키넥트 (Kinect)를 개발함에 따라 저렴한 가격에 부가적인 장치 필요 없이 간단한 조작만으로도 3D 모션 정보 취득이 가능해졌다. 하지만 키넥트 카메라는 마커 기반 모션 캡쳐 시스템에 비해 관절 정보의 추정 성능이 뒤떨어져 낮은 정확도를 보이는 단점을 지니고 있다. 이에 본 논문에서는 키넥트 카메라를 이용해 사람의 관절 정보를 취득하고 이것에 관절 가동 범위 (Range of Motion, ROM)를 적용하여 비정상적인 동작을 보정하는 시스템을 제안한다. ROM을 구하는 방법으로는 수행자가 모든 관절에 대해 회전 운동을 수행한 뒤 관절들의 회전 운동 정보를 취득, 분석하여 정상적인 ROM을 설정하고 실험으로부터 사람의 동작이 개선되는 것을 확인하였다.

  • PDF

New Encoding Method for Low Power Sequential Access ROMs

  • Cho, Seong-Ik;Jung, Ki-Sang;Kim, Sung-Mi;You, Namhee;Lee, Jong-Yeol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.443-450
    • /
    • 2013
  • This paper propose a new ROM data encoding method that takes into account of a sequential access pattern to reduce the power consumption in ROMs used in applications such as FIR filters that access the ROM sequentially. In the proposed encoding method, the number of 1's, of which the increment leads to the increase of the power consumption, is reduced by applying an exclusive-or (XOR) operation to a bit pair composed of two consecutive bits in a bit line. The encoded data can be decoded by using XOR gates and D flip-flops, which are usually used in digital systems for synchronization and glitch suppression. By applying the proposed encoding method to coefficient ROMs of FIR filters designed by using various design methods, we can achieve average reduction of 43.7% over the unencoded original data in the power consumption, which is larger reduction than those achieved by previous methods.

A Design of a Diredt Digital Frequency Syntheszer with an Array Type CORDIC Pipeline (파이프라인형 CORDIC를 이용한 직접 디지털 주파수 합성기 설계)

  • 남현숙;김대용;유영갑
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.5
    • /
    • pp.36-43
    • /
    • 1999
  • A new design of a Direct Digital Frequency Synthesizer(DDFS) is presented, where a pipelined Coordinate Rotate Digital Computer(CORDIC) circuit is employed to calculate amplitude values of all the phase angles of sinusoidal waveforms produced. a near-optimal number of pipeline stages is determined based on an error analysis of calculated amplitude values in terms of the number of bits. The DDFS was implemented using a field programmable gate array, yielding a stable operating frequency of 11.75MHz. The measurement results show higher resolution, faster operating speed and simpler fabrication process, compared to ROM-based counterparts. The CORDIC-based DDFS yields 5 times higher resolution than conventional ROM-based versions.

  • PDF

Random Signal Characteristics of Super-RENS Disc (Super-RENS Disc의 Random 신호 특성)

  • Bae Jaecheol;Kim Jooho;Kim Hyunki;Hwang Inho;Park Changmin;Park Hyunsoo;Jung Moonil;Ro Myongdo
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.119-123
    • /
    • 2005
  • We report the random pattern characteristics of the super resolution near field structure(Super-RENS) write once read-many(WORM) disc at a blue laser optical system(laser wavelength 405nm, numerical aperture 0.85) and the Super-RENS read only memory(ROM) disc at a blue laser optical system(laser wavelength 659nm, numerical aperture 0.65). We used the WORM disc of which carrier-to-noise ratio (CNR) of 75nm is 47dB and ROM disc of which carrier-to-noise ratio (CNR) of 173nm is 45dB. We controlled the equalization (EQ) characteristics and used advanced partial-response maximum likelihood (PRML) technique. We obtained bit error rate (bER) of 10-3 level at 50GB WORM disc and bite error rate of 10-4 level at 50GB level ROM disc. This result shows high feasibility of Super-RENS technology for practical use.

  • PDF

Random Signal Characteristics of Super-RENS Disc (Super-RENS Disc의 Random 신호 특성)

  • Bae, Jae-Cheol;Kim, Joo-Ho;Kim, Hyun-Ki;Hwang, In-Oh;Park, Chang-Min;Park, Hyun-Soo;Jung, Moon-Il;Ro, Myong-Do
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.38-42
    • /
    • 2006
  • We report the random pattern characteristics of the super resolution near field structure(Super-RENS) write once read-many(WORM) disc at a blue laser optical system(laser wavelength 405nm, numerical aperture 0.85) and the Super-RENS read only memory(ROM) disc at a blue laser optical system(laser wavelength 659nm, numerical aperture 0.65). We used the WORM disc of which carrier-to-noise ratio(CNR) of 75nm is 47dB and ROM disc of which carrier-to-noise ratio(CNR) of 173nm is 45dB. We controlled the equalization(EQ) characteristics and used advanced partial-response maximum likelihood(PRML) technique. We obtained bit error rate(bER) of 10-3 level at 50GB WORM disc and bite error rate of 10-4 level at 50GB level ROM disc. This result shows high feasibility of Super-RENS technology for practical use.

  • PDF

Effects of Artificial Leg Length Discrepancies on the Dynamic Joint Angles of the Hip, Knee, and Ankle During Gait

  • Kim, Yong-Wook;Jo, Seung-Yeon;Byeon, Yeoung-In;Kwon, Ji-Ho;Im, Seok-Hee;Cheon, Su-Hyeon;Kim, Eun-Joo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • PURPOSE: This study examined the dynamic range of motion (ROM) of the hip, knee, and ankle joint when wearing different shoe sole lifts, as well as the limb asymmetry of the range according to the leg length discrepancy (LLD) during normal speed walking. METHODS: The participants were 40 healthy adults. A motion analysis system was used to collect kinematic ROM data. The participants had 40 markers attached to their lower extremities and were asked to walk on a 6 m walkway, under three different shoe lift conditions (without an insole, 1 cm insole, and 2 cm insole). Visual3D professional software was used to coordinate kinematic ROM data. RESULTS: Most of the ROM variables of the short limbs were similar under each insole lift condition (p>.05). In contrast, when wearing a shoe with a 2 cm insole lift, the long limbs showed significant increases in flexion and extension of the knee joint as well as; plantarflexion, dorsiflexion, pronation, eversion, and inversion of the ankle joint (p<.05). Of the shoes with the insole lifts, significant differences in all ROM variables were observed between the left and right knees, except for the knee internal rotation (p<.05). CONCLUSION: As the insole lift was increased, more ROM differences were observed between the left and right limbs, and the asymmetry of the bilateral lower limbs increased. Therefore, appropriate interventions for LLD are needed because an artificial mild LLD of less than 2.0 cm could lead to a range of musculoskeletal problems of the lower extremities, such as knee and ankle osteoarthritis.

Robust servo control of high speed optical disk drives (고속 광 디스크 드라이브의 강인 서보제어)

  • 임승철;정태영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.438-444
    • /
    • 1997
  • Recently, optical disk drives are increasingly demanded to have higher speed as well as high information density, especially for applications like CD-ROM drives. To this end, improvement of their optical pick-up structure and control is recognized the very challenging issue. In this paper, the 2-D motion of the pick-up is first analytically modelled to identify the cause and effect of the troublesome cross coupling between auto-focusing and tracking directions. Subsequently, the overall system equations are derived to include the dynamics of the related components in the auto-focusing servo system. While its unmeasurable parameters being estimated by the least square error method, a simple but decent linear model can be obtained within its operating frequency range. To design the high speed and robust positional servo controller, the design specifications are detailed and H$\sub$.inf./ control method is employed based on the simple model. Using the pickup in a commercial 8 fold speed CD-ROM drive as an example, performance of the designed controller is verified by realtime experiments.

  • PDF

Effects of the Flex-OA Functional Shoe and the Standardized Shoe on Ranges of Hip and Knee Joint During Gait in Healthy Individuals (정상 성인에서 Flex-OA 기능성 신발과 일반 신발이 보행 중 엉덩관절과 무릎관절의 가동범위에 미치는 효과)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the characteristics of the Flex-OA shoe, a specific functional shoe, in terms of the range of motion (ROM) of hip and knee joint during walking when compared to a standardized shoe. Methods : Twenty-six healthy adults (18 males, 6 females) participated in this study. Subjects performed 8 walking trials consisting of two different shoe conditions to evaluate the hip and knee ROM using a three-dimensional motion capture system. Visual 3D motion analysis software was finally used to coordinate the kinematic data. Result : The total ROM and maximal abduction range of the hip joint in the coronal planes when wearing the Flex-OA shoe were significantly increased during walking compared to wearing a standard shoe (p<.05). On the other hand, significantly increased ROM was observed in the sagittal plane when wearing the Flex-OA shoe in the knee joints compared to a standard shoe (p<.05). Conclusion : Although clinical application of the specific functional shoe has known clearly positive effects on knee moments, the results of this study could provide important clues to explain the background of these effects in terms of the hip and knee joints when applying a specific functional shoe.