• Title/Summary/Keyword: cyclone

Search Result 592, Processing Time 0.026 seconds

Relationship between the Outer Vortex and the Collection Efficiency with respect to Temperatures in the Cyclone Dust Collector (사이클론 집진장치의 내부온도에 따른 외부 소용돌이와 집진효율의 관계)

  • Hyun, Daegeun;Chang, Hyuksang
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.47-55
    • /
    • 2015
  • This study compares the results of collection efficiency of difference gas temperature in cyclone dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $600^{\circ}C$ and $1000^{\circ}C$. As the temperature decreases, the average velocity of outer vortex and collection efficiency is increased, showed the highest collection efficiency at $20^{\circ}C$. It can be inferred smooth flow in cyclone dust collector is difficult because air viscosity increases as temperature increases. The power required at $1000^{\circ}C$ is almost 18 times greater than that of $20^{\circ}C$ to get the similar collection efficiency.

Development of Cyclone Conveying System for Transporting Chopped Round Bale Roughage and Separating Dust (흙먼지 분리기 용이한 원형베일 세절 조사료의 사이클론 이송장치 개발)

  • Ha, Yu-Shin;Kwon, Jin-Kyung;Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.204-210
    • /
    • 2011
  • This study developed the cyclone conveying system using roughage cutter for the round bale reported in the previous papers. Performance tests were conducted whether it can easily separate dust from roughage such as rice straws and it can transport roughages from cutter to TMR mixer. In addition, the airflow patterns in the cyclone conveying system were investigated using CFD code (FLUENT 6.2) for various velocities of dust collection fan. The cyclone conveying system was designed based on dried rice straws with a diameter of 1,340 mm, a cylinder length of 1,220 mm, a cone length of 850 mm and the current velocity of the dust collection fan was 15~20 m/s. It was found that transporting of roughage from cutter to TMR mixer and the separation of dust were satisfactory, and the dust removal rate of rice straws was around 31.9%. CFD analysis showed that, at the blowing fan velocity of 11.6 m/s, the airflow velocity inside the dust collector increased as velocity of the dust collection fan increased, but the airflow patterns inside the dust collector were all much the same.

A Numerical Analysis on the Flow Characteristics and the Collection Efficiency for Fine Particles in a Cyclone (사이클론 내 유동특성 및 미세입자 집진효율에 대한 수치해석적 연구)

  • Yong, Jung-Kwon;Kim, Chang-Nyung;Jo, Young-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.144-153
    • /
    • 2008
  • A numerical analysis has been carried out to examine the flow characteristics and the collection efficiency for fine particles in a cyclone using Computational Fluid Dynamics (CFD) technique. The cyclone with the cylinder diameter of 60 mm has been considered for the investigation of the particle collection in a relatively smaller cyclone with somewhat higher inlet air velocities. Fundamental air flow patterns for different inlet velocities have been calculated and then the motions of particles of different sizes have been obtained. The calculated collection efficiencies for fine particles are compared with the experimental results, which shows a good agreement. The current result can be used for the design of cyclones with high collection efficiency.

CFD Simulation of Air-particle Flow for Predicting the Collection Efficiency of a Cyclone Separator in Mud Handling System (Mud handling system 내 cyclone separator의 집진효율 추정을 위한 공기-분체의 CFD 시뮬레이션)

  • Jeon, Gyu-Mok;Park, Jong-Chun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.42-49
    • /
    • 2019
  • Drilling mud was used once in the step of separating the gas and powder they were transported to a surge tank. At that time, the fine powder, such as dust that is not separated from the gas, is included in the gas that was separated from the mud. The fine particles of the powder are collected to increase the density of the powder and prevent air pollution. To remove particles from air or another gas, a cyclone-type separator generally can be used with the principles of vortex separation without using a filter system. In this study, we conducted numerical simulations of air-particle flow consisting of two components in a cyclone separator in a mud handling system to investigate the characteristics of turbulent vortical flow and to evaluate the collection efficiency using the commercial software, STAR-CCM+. First, the single-phase air flow was simulated and validated through the comparison with experiments (Boysan et al., 1983) and other CFD simulation results (Slack et al., 2000). Then, based on one-way coupling simulation for air and powder particles, the multi-phase flow was simulated, and the collection efficiency for various sizes of particles was compared with the experimental and theoretical results.

A Study on Optimum Design of an Axial Cylcone structure using Response Surface Method (반응표면법을 활용한 축류형 사이클론 구조 최적화 설계에 관한 연구)

  • Cho, Jinill;Yun, Junho;Cho, Yeongkwang;Seok, Hyunho;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.17 no.3
    • /
    • pp.71-79
    • /
    • 2021
  • Ultrafine dust, which is emitted from industrial factories or all kinds of vehicles, threatens the human's respiratory system and our environment. In this regard, separating airborne particles is essential to mitigate the severe problem. In this work, an axial cyclone for the effective technology of eliminating harmful dust is investigated by numerical simulation using Ansys 2020, Fluent R2. In addition, the optimized structure of the cyclone is constructed by means of multi objective optimization based on the response surface method which is a representative method to analyze the effect of design parameter on response variables. Among several design parameters, the modified length of the vortex finder and dust collector is a main point in promoting the performance of the axial cyclone. As a result, the optimized cyclone exhibits remarkable performance when compared to the original model, resulting in pressure drop of 307 Pa and separator efficiency of 98.5%.

Mechanism Study of Tropical Cyclone Impact on East Asian Subtropical Upper-Level Jet: a Numerical Case Investigation

  • Chen, Xian;Zhong, Zhong;Lu, Wei
    • Asia-Pacific Journal of Atmospheric Sciences
    • /
    • v.54 no.4
    • /
    • pp.575-585
    • /
    • 2018
  • In the case study of this paper, sensitivity experiments are carried out using the mesoscale non-hydrostatic Weather Research and Forecasting (WRF) model to investigate the impact of tropical cyclone (TC) Soudelor (2003) on the East Asian subtropical upper-level jet (EASJ) before TC Soudelor transformed into an extratropical cyclone. The physical mechanism for changes in the EASJ intensity and position caused by TC Soudelor is explored. Results indicate that TC Soudelor would warm the air in the middle and upper troposphere over the Japan Sea and the adjacent areas through stimulating northward propagating teleconnection pattern as well as releasing large amounts of latent heat, which led to increase (decrease) the meridional air temperature gradient to the south (north) below the EASJ axis. As a result, the geopotential height abnormally increased in the upper troposphere, resulting in an anomalous anticyclonic circulation belt along the EASJ axis. Correspondingly, the westerly winds to the north (south) of the EASJ axis intensified (weakened) and the EASJ axis shifted northward by one degree. The case study also suggests that before the extratropical cyclone transition of TC Soudelor, the TC activities had exerted significant impacts on the EASJ through thermodynamic processes.

Analysis and Evaluation of Separation Efficiency on Mass Flow of Mini Hydro Cyclone Separator Manufactured by 3D Printing (3D 프린팅을 적용한 미니 하이드로 싸이클론 분리기의 질량유량을 통한 분리효율 해석 및 평가)

  • Yi, Hyung-wook;Lee, Yeo-ul;Lee, Myung-won;Kwon, Je-young;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.89-96
    • /
    • 2021
  • In this study, a mini hydro cyclone was designed and manufactured to achieve an inlet flow rate of 2 L/min in the experiment, which was conducted using alumina powder with a specific gravity of 3.97. This hydro cyclone was studied for using in steam and water analysis system (SWAS) of thermal power plant and was manufactured by 3D printing. Numerical analysis was performed with Solidworks Flow Simulation, utilizing the reynolds stress method (RSM) of fluid multiphase flow analysis models. Experimental and numerical analysis were performed under the three conditions of inlet velocity 2.0, 4.0, and 6.0 m/s. The separation efficiency was over 80% at all inlet velocity conditions. At the inlet velocity 4m/s, the separation efficiency was the best, and it was confirmed that the efficiency was more than 90%.

Evaluation of Performance Characteristics by Dual Arrangement of Mini-hydrocyclone Separators (미니 하이드로 사이클론 분리기의 이중배열을 통한 성능특성 평가)

  • Kwon, Je-Young;Kim, Seung-Kyung;Hong, Jun-Gyu;Yi, Hyung-Wook;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.17-23
    • /
    • 2021
  • A cyclone is a dust-separating mechanism that works on the principle of centrifugal force. The performance of a cyclone is evaluated using pressure loss and collection efficiency. A multi-cyclone arrangement is used to improve the collection efficiency within a limited area. In this study, experiments and numerical analyses were conducted on a dual arrangement of mini-hydrocyclone separators, which was fabricated using 3D printing. The experiment was performed at an inlet flow rate of 0.7 m/s, and alumina powder with a particle size of 0.5, 15, and 50 ㎛. ANSYS FLUENT, was used for the numerical analysis. The reliability of the numerical analysis was verified through a comparison with the experimental results. The errors in the experiment and numerical analysis were confirmed to be 2% at the outlet flow rate.

A STUDY ON CYCLONE SYSTEM ASSISTING FOR THE REVISION OF CONSTRUCTION STANDARD PRODUCTION UNIT SYSTEM

  • Tae-Kyung Lim;Han-Seong Gwak;Won-Sang Shin;Chang-Baek Son;Dong-Eun Lee
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.583-586
    • /
    • 2013
  • Construction processes are highly repetitive. A resource entity continuously cycles through work tasks that processes or uses resources. Web-CYCLONE (Halpin 1992) has been accepted as a useful tool for modeling and analyzing a specific operation. However the system has a lack of practicality as follows: (1) it does not efficiently record and keep track of operation models in a database; (2) it does not provide the functions which facilitate to retrieve corresponding model and to update local variables of the model using observed data; (3) it does not automate the complex process that executes simulation experiment, analyzes simulation outputs and generates a report on behalf of the practitioners. Therefore, practitioners have a difficulty in reusing, modifying and analyzing the existing operation models. This study introduces a Client/Server based CYCLONE that improves above-mentioned limitations in the existing Web-CYCLONE. The system was illustrated by revising CSPU in practice.

  • PDF

Performance Evaluation of a Electro-Double Cyclone (전기 Double Cyclone의 성능평가)

  • 임경수;김현수;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.399-400
    • /
    • 2003
  • 싸이클론은 대기오염물질의 샘플링과 여러 산업공정에서 분진을 제어, 분리하는데 널리 사용되고 있다. 이는 싸이클론의 구조 및 형태가 간단하여, 제작과 운전이 쉽고 비용이 적게 들기 때문이다 하지만 작은 입자에 대한 분리효율이 낮기 때문에 싸이클론의 구조 및 형태를 변화시키거나 싸이클론내에 운전 조건을 변화시켜 높은 분리효율을 얻으려는 연구가 수행되어 왔다. 특히, 싸이클론내에 이중으로 원심력이 작용하게 한 double cyclone(Zhu et al., 2001)과 입자 하전 및 전기장 형성을 위해 고전압을 인가하는 전기싸이클론이(Lim et al., 2001) 최근에 연구가 되어지고 있다. (중략)

  • PDF