• 제목/요약/키워드: cycling loading

검색결과 87건 처리시간 0.02초

Delamination behaviors of GdBCO CC tapes under different transverse loading conditions

  • Gorospe, Alking B.;Bautista, Zhierwinjay M.;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.13-17
    • /
    • 2015
  • In superconducting coil applications particularly in wet wound coils, coated conductor (CC) tapes are subjected to different type of stresses. These include hoop stress acting along the length of the CC tape and the Lorentz force acting perpendicular to the CC tape's surface. Since the latter is commonly associated with delamination problem of multi-layered CC tapes, more understanding and attention on the delamination phenomena induced in the case of coil applications are needed. Difference on the coefficient of thermal expansion (CTE) of each constituent layer of the CC tape, the bobbin, and the impregnating materials is the main causes of delamination in CC tapes when subjected to thermal cycling. The CC tape might also experience cyclic loading due to the energizing scheme (on - off) during operation. In the design of degradation-free superconducting coils, therefore, characterization of the delamination behaviors including mechanism and strength in REBCO CC tapes becomes critical. In this study, transverse tensile tests were conducted under different loading conditions using different size of upper anvils on the GdBCO CC tapes. The mechanical and electromechanical delamination strength behaviors of the CC tapes under transverse tensile loading were examined and a two-parameter Weibull distribution analysis was conducted in statistical aspects. As a result, the CC tape showed similar range of mechanical delamination strength regardless of cross-head speed adopted. On the other hand, cyclic loading might have affected the CC tape in both upper anvil sizes adopted.

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

Preparation and Electrochemical Performance of CNT Electrode with Deposited Titanium Dioxide for Electrochemical Capacitor

  • Kim, Hong-Il;Kim, Han-Joo;Morita, Masayuki;Park, Soo-Gil
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권2호
    • /
    • pp.423-428
    • /
    • 2010
  • To reduce polarization of electrochemical capacitor based on carbon nanotube, titanium oxide nanoparticles were deposited by ultrasound. The pore distribution of $TiO_2$/CNT nanoparticle exhibited surface area of $341\;m^2g^{-1}$ when $TiO_2$ content was 4 wt %, which was better than that of pristine CNT with surface area of $188\;m^2g^{-1}$. The analyses indicated that titanium oxide (particle diameter < 20 nm) was deposited on the CNT surface. The electrochemical performance was evaluated by using cyclic voltammetry (CV), impedance measurement, and constant-current charge/discharge cycling techniques. The $TiO_2$/CNT composite electrode showed relatively better electrochemical behaviors than CNT electrode by increasing the specific capacitance from $22\;Fg^{-1}$ to $37\;Fg^{-1}$ in 1 M $H_2SO_4$ solution. A symmetric cell assembled with the composite electrodes showed the specific capacitance value of $11\;Fg^{-1}$ at a current loading of $0.5\;mAcm^{-2}$ during initial cycling.

온도 변화가 교정용 니켈-티타늄 호선의 하중값에 미치는 영향 (The effect of temperature changes on force level of superelastic nickel-titanium archwires)

  • 천경애;김광원;임성훈
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.432-439
    • /
    • 2007
  • 초탄성 니켈-티타늄 호선의 하중값은 온도 변화에 따라 변화함이 보고된 바 있다. 따라서 본 연구에서는 온도가 변화함에 따라 니켈-티타늄 합금 호선의 하중값이 어떻게 변화하는지 알아보고자 하였다. $37^{\circ}C$ 항온 상태에서 $0.016"{\times}0.22"$ 니켈-티타늄 호선을 3.1 mm까지 변위시키는 3점 굴곡 실험을 시행하여 하중 시와 탈하중 시의 1.5mm 변위지점의 하중값을 측정하고 이 지점에서 구강내 온도 변화를 고려한 온도 변화 실험을 시행하였다. $20^{\circ}C$ 저온수 또는 $50^{\circ}C$ 고온수를 호선에 흘려보냄으로써 온도 변화를 주었다. 저온 실험은 저온수로 온도 변화를 주고 $37^{\circ}C$ 항온 온도로 회복된 후에 다시 저온수를 흐르게 하는 방법으로 10회 시행하였고 고온 실험도 동일한 방법으로 시행하였다. 그 결과 하중 시 1.5mm 변위지점의 하중값은 저온 실험 및 고온 실험 후 $37^{\circ}C$로 회복된 후에도 모두 감소된 값을 유지하였다. 반대로 실제로 치아에 가해지는 교정력으로 생각되는 탈하중 시 1.5 mm 변위 지점의 하중값은 저온 실험 및 고온 실험 후 온도가 $37^{\circ}C$로 회복되어도 모두 증가된 값을 유지하였다. 이상의 결과를 종합해 볼 때 온도변화를 거친 후 초탄성 니켈-티타늄 합금 호선의 하중 시 힘은 감소하였고 탈하중 시 힘은 증가되므로, 임상에서 니켈-티타늄 호선을 적용 시에는 $37^{\circ}C$에서의 하중-변위 곡선에서 나타나는 힘에 비해 더 작은 하중 시 힘과 더 큰 탈하중 시 힘이 적용될 수 있음에 유의하여야 한다.

치과용 저작 매스티케이터의 개발 (Development of Dental Chewing Masticator)

  • 이권용;정일영;박성호;전승범
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.255-258
    • /
    • 2002
  • Dental chewing masticator, which is an essential device for evaluating the wear of dental resin and the interfacial failure between the filling resin and enamel of tooth used in conservative dentistry, was developed. This dental chewing masticator mimics the chewing motion and loading by adapting DC motor and rotary cam system. Chewing loading of 49N was imposed by computer-displacement control, loadcell, LM guide, and spring system. Extracted tooth was fixed into a holding jig, and this jig was mounted with rubber pad on the $15^{\circ}$inclined surface to consider the lateral movement of periodontal ligament. A water bath was installed for providing the environment of inside mouth and for circulating the $5^{\circ}C-55^{\circ}C$ water to evaluate the effect of hydrothermal cycling on the damage of resin filled teeth during long-term chewing activity.

  • PDF

Effectiveness of R/C jacketing of substandard R/C columns with short lap splices

  • Kalogeropoulos, George I.;Tsonos, Alexander G.
    • Structural Monitoring and Maintenance
    • /
    • 제1권3호
    • /
    • pp.273-292
    • /
    • 2014
  • The effectiveness of a retrofitting method for concrete columns with particular weaknesses is experimentally evaluated and presented in this paper. Structural deficiencies namely the inadequacy of transverse reinforcement and short length of lap splices are very common in columns found in structures built prior to the 1960s and 1970s. Recent earthquakes worldwide have caused severe damages and collapses of these structures. Nevertheless, the importance of improving the load transfer capacity between the deficiently lap-spliced bars is usually underestimated during the strengthening procedures applied in old buildings, though critical for the safety of the residents' lives. Thus, the seismic performance of the enhanced columns is frequently overestimated. The retrofitting approach presented herein involves reinforced concrete jacketing of the column sub-assemblages and welding of the lap-spliced bars to prevent the splice failure and conform to the provisions of modern design Codes. The cyclic lateral loading response of poorly confined original column specimens with insufficient lap splices and the seismic behavior of the retrofitted columns are compared. Test results clearly demonstrate that the retrofitting procedure followed is an effective way of significantly improving the seismic performance of substandard columns found in old buildings.

현장 데이터를 이용한 연성포장용 피로 공용성 예측모델 검정 (Calibration of Fatigue Performance Prediction Model for Flexible Pavements Using Field Data)

  • 김낙석
    • 한국재난정보학회 논문집
    • /
    • 제8권3호
    • /
    • pp.234-241
    • /
    • 2012
  • 본 연구의 주 목적은 다층 구조를 가진 아스팔트 포장체의 피로균열에 대한 공용성 예측모델을 검정하는 것이다. 그러나, 검정 인자는 목표로 하는 예측모델, 시험법 및 시험중 하중이력에 따라 차이가 있을 수 있다. 본 연구에서 수행된 다양한 현장 조사에 의하면, 연성포장의 피로공용성은 교통하중뿐만 아니라 포장체의 완성후 경과기간에 영향을 받는 것으로 나타났다. 이에 따른 각각의 교통하중과 경과기간에 대한 가중치가 본 연구에서 제시되었다. 또한, 기 발표된 피로 예측모델을 바탕으로 실내와 현장조사를 통하여 얻어진 피로균열 데이터의 상호 상관관계를 분석하여 피로 예측모델에 대한 검정 인자가 개발되었다.

Experimental research on dynamic response of red sandstone soil under impact loads

  • Wang, Tong;Song, Zhanping;Yang, Jianyong;Wang, Junbao;Zhang, Xuegang
    • Geomechanics and Engineering
    • /
    • 제17권4호
    • /
    • pp.393-403
    • /
    • 2019
  • The cycling impact test of red sandstone soil under different axial pressure and different impact loads are conducted to reveal the mechanical properties and energy consumption mechanism of red sandstone soil with static-dynamic coupling loading. The results show that: Under the action of different axial pressure and different impact loads, the peak stress of the specimen increases, and then tends to be stable with the times of impact. With the increase of impact times, the specific energy absorption value of the red sandstone soil specimen is increased first and then gentle development trend. When the impact loads are certain, the larger the axial pressure is, the smaller the peak value of energy absorption, which indicates that the energy utilization rate is not high under the condition of large axial pressure. Through the analysis of energy utilization, it is found that the smaller the impact load, the higher the energy utilization rate. The greater the axial pressure, the lower the energy utilization rate. when the axial pressure is large, the impact loads corresponding to the maximum values of reflectivity, transmissivity and absorptivity are the same. The relationship between reflectivity and transmissivity is negatively correlated.

Electrochemical Characteristics of Silicon-carbon Composite Anodes for Lithium Rechargeable Batteries

  • Lee, Jaeho;Won, Sora;Shim, Joongpyo;Park, Gyungse;Sun, Ho-Jung;Lee, Hong-Ki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.193-197
    • /
    • 2014
  • Si-carbon composites as anode materials for lithium rechargeable batteries were prepared simply by mixing Si nanoparticles with carbon black and/or graphite through a solution process. Si nanoparticles were well dispersed and deposited on the surface of the carbon in a tetrahydrofuran solution. Si-carbon composites showed more than 700 mAh/g of initial capacity under less than 20% loading of Si nanoparticle in the composites. While the electrode with only Si nanoparticles showed fast capacity fading during continuous cycling, Si-carbon composite electrodes showed higher capacities. The cycle performances of Si nanoparticles in composites containing graphite were improved due to the role of the graphite as a matrix.

열하중과 굽힘 하중 조건에서의 솔더조인트 피로 특성 비교연구 (A Comparative study on the solder joint fatigue under thermal and mechanical loading conditions)

  • 김일호;이순복
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권2호
    • /
    • pp.45-55
    • /
    • 2007
  • In this study, two types of fatigue tests were conducted. Firs, cyclic bending tests were performed using the micro-bending tester. Second, thermal fatigue tests were conducted using a pseudo power cycling machine which was newly developed for a realistic testing condition. A three-dimensional finite element analysis model was constructed. A finite element analysis using ABAQUS was performed to extract the applied stress and strain in the solder joints. Creep deformation was dominant in thermal fatigue and plastic deformation was main parameter for bending failure. From the inelastic energy dissipation per cycle versus fatigue life curve, it can be found that the bending fatigue life is longer than the thermal fatigue life.

  • PDF