• Title/Summary/Keyword: cyclic behaviour

Search Result 206, Processing Time 0.023 seconds

Large-scale cyclic test on frame-supported-transfer-slab reinforced concrete structure retrofitted by sector lead rubber dampers

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Da yang Wang;Ke Jiang;Song Wang
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.383-400
    • /
    • 2024
  • For a conventionally repaired frame-supported-transfer-slab (FSTS) reinforced concrete (RC) structure, both the transfer slab and the beam-to-column and transfer slab-to-column joints remain vulnerable to secondary earthquakes. Aimed at improving the seismic performance of a damaged FSTS RC structure, an innovative retrofitting scheme is proposed, which adopts the sector lead rubber dampers (SLRDs) at joints after the damaged FSTS RC structure is repaired by conventional approaches. In this paper, a series of quasi-static cyclic tests was conducted on a large-scale retrofitted FSTS RC structure. The seismic performance was evaluated and the key test results, including deformation characteristics, damage pattern, hysteretic behaviour, bearing capacity and strains on key components, were reported in detail. The test results indicated that the SLRDs started to dissipate energy under the service level earthquake, and thus prevented damages on the beam-to-column and transfer slab-to-column joints during the secondary earthquakes and shifted the plastic hinges away from the beam ends. The retrofitting scheme of using SLRDs also achieved the seismic design concept of 'strong joint, weak component'. The FSTS RC structure retrofitted by the SLRDs could recover more than 85% bearing capacity of its undamaged counterpart. The hysteresis curves were featured by the inverse "S" shape, indicating good bearing capacity and hysteresis performance. The deformation capacity of the damaged FSTS RC structure retrofitted by the SLRDs met the corresponding codified requirements for the case of the maximum considered earthquake, as set out in the Chinese seismic design code. The stability of the FSTS RC structure retrofitted by the SLRDs, which was revealed by the developed stains of the RC frame and transfer slab, was improved compared with the undamaged FSTS RC structure.

Stiffness Evaluation of Steel Beam-to-Column Joints Using Component method (Component method를 이용한 철골 보-기둥 죠인트의 강성평가)

  • 양철민;조지은;김영문
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.243-250
    • /
    • 2004
  • This paper reports on the evaluation of the initial stiffness of steel joints using component method as well as experimental tests. The so-called component method corresponds precisely to a simplified mechanical model composed of extensional springs and rigid links, whereby the joint is simulated by an appropriate choice of rigid and flexible components. An application to a cantilever beam-to-column steel joint is presented and compared to the experimental results obtained under cyclic loading condition. Comparison between numerical and experimental results allows to conclude that the numerical model is able to simulate, with a good level of accuracy for initial stiffness, the behaviour of beam-to-column joints.

  • PDF

Synthesis and Characterization of Conductive Polyaniline-Modified Polymers via Nitroxide Mediated Radical Polymerization (NMRP 중합법을 이용한 전도성 폴리아닐린-수식 고분자의 제조와 특성)

  • Jaymand, Mehdi
    • Polymer(Korea)
    • /
    • v.34 no.6
    • /
    • pp.553-559
    • /
    • 2010
  • The paper describes the preparation and characterization of conductive polyaniline-modified polymers by growing of aniline onto functionalized poly(styrene-co-p-methylstyrene) [P(St-co-MSt)]. For this purpose, P(St-co-MSt) was synthesized via nitroxide mediated radical polymerization (NMRP) and then N-boromosuccinimide was used for introduction of bromine to the benzylic positions of copolymer. Afterwards, 1,4-phenylenediamine was linked to the brominated P(St-co-MSt) and functionalized copolymer $[P(St-co-MSt)-NH_2]$ was prepared. The graft copolymerization of aniline monomers onto functionalized P(St-co-MSt) was initiated by oxidized phenylamine groups after addition of ammonium peroxydisulfate (APS), and p-toluenesulfonic acid-doped PANI was chemically grafted onto P(St-co-MSt) via oxidation polymerization. The obtained terpolymer was studied by FTIR and UV-Vis spectroscopy and its thermal behaviour were examined by DSC and TGA analyses. The conductivity of terpolymer was measured by four-point probe method and electroactivity was measured by cyclic voltammetry (CV). The solubility of P(St-co-MSt)-g-PANI was examined in common organic solvents.

Characteristic Behavior of High-Strength Reinforced Concrete Bridge Column under Simulated Seismic Loading (고강도 철근콘크리트 교각의 내진거동특성)

  • Ra Hong-Seong;Lee Kyoung-Joon;Ryu Hyo-Jin;Hwang Sun-Kyoung;Lee Chin-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.22-27
    • /
    • 2004
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (ps = 0.96, 1.44 per cent) and axial load ratio (0.05, 0.1, 0.2 P/Po) and strength $(350kgf/cm^2,\;600kgf/cm^2)$. Test results show that bridge columns with 50 per cent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of Mmax over Mad, nominal moment capacity predicted by ACI 318-02 provisions, is consistently greater than 1 with approximately a 20 percent margin of safty.

  • PDF

A Study on Damage-Assessment of RC Large Cooling Tower Shells (RC 대형 냉각탑 셀의 손상추정에 관한 연구)

  • Noh, Sam-Young
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.279-286
    • /
    • 2004
  • An accumulated crack damage which propagates progressively with time was frequently observed on several engineering structures, This paper numerically demonstrates this damage process on large cooling tower shells under thermal and wind loads. Damage states under varying loads are investigated and the influence of this progressive damage process on the life-cycle of cooling towers discussed. The paper presents briefly some fundamentals of the geometrically and physically non-linear numerical analysis employed for reinforced concrete, especially concerning the models used for concrete, steel reinforcement and the bond between them. As a numerical example an existing cooling tower with noticeable meridian crack damage is analysed. The existing damage state of the cooling tower is determined by quasi-static analyses for temperature, hygric and cyclic wind leading. The change in the dynamical behaviour of the structure as mirrored in its natural frequencies and mode shapes is presented and discussed. Finally, the example shows that such damage processes develop progressively over the life-time of the structures.

  • PDF

An experimental-computational investigation of fracture in brittle materials

  • De Proft, K.;Wells, G.N.;Sluys, L.J.;De Wilde, W.P.
    • Computers and Concrete
    • /
    • v.1 no.3
    • /
    • pp.227-248
    • /
    • 2004
  • A combined experimental-computational study of a double edge-notched stone specimen subjected to tensile loading is presented. In the experimental part, the load-deformation response and the displacement field around the crack tip are recorded. An Electronic Speckle Pattern Interferometer (ESPI) is used to obtain the local displacement field. The experimental results are used to validate a numerical model for the description of fracture using finite elements. The numerical model uses displacement discontinuities to model cracks. At the discontinuity, a plasticity-based cohesive zone model is applied for monotonic loading and a combined damage-plasticity cohesive zone model is used for cyclic loading. Both local and global results from the numerical simulations are compared with experimental data. It is shown that local measurements add important information for the validation of the numerical model. Consequently, the numerical models are enhanced in order to correctly capture the experimentally observed behaviour.

A study on the behaviour of axisymmetric outer tube and inner movable part(case) under pressure and thermal load (열하중 및 내압을 받는 축대칭 튜브와 내부 운동체의 거동해석 연구)

  • Kim, I.W.;Lee, S.B.;Park, Y.J.;Lee, Y.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.114-125
    • /
    • 1993
  • Thermoelastoplastic analysis of a typical device consisting of fixed tube and movable case having an inital clearance in between, which is subjected to pressure and thermal load, has been carried out to examine the cause of malfunction mainly at high temperature condition, and to improve the design. Stresses, deformed shape, interface state and their effects on normal function of case are discussed by using finite element method. The extraction energy can be remarkably reduced by changing the configuration of tube from the present design (Parallel type) to the improved design (Tapered type). This effect has been proved by sustained cyclic function test.

  • PDF

Shear Damage Behavior of Reinforced Concrete Beams under Repetitive Fatigue Loadings (반복하중을 받는 철근콘크리트보의 전단피로손상거동)

  • Oh, Byung-Hwan; Han, Seung-Hwan;Yoo, Young;Cho, Jae-Yeol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.633-638
    • /
    • 1997
  • This study was performed to investigate the fatigue behaviour and fatigue damage process of RC structures under repeated load. Especially, the behavior of RC beams subjected to flexure-shear force has been focused. The test results show that the deflections of beam and the strains of longitudinal steels and stirrups under cyclic loads increase with constant rate, and these increases depend on diagonal crack openings and strain increases. The present study provides useful data for the analysis of damage accumulation of reinforced concrete beams under repeated loadings.

  • PDF

Analysis of Shear Damage Behaviour of Reinforced Concrete Beams using Modified Compression Field Theory (철근콘크리트보의 전단피로손상거동에 대한 수정압축장이론을 이용한 해석기법)

  • 한승환;오병환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.552-557
    • /
    • 1997
  • In this study, a quantitative analysis technique for the damage process of reinforced concrete beams under repeated shear loading is proposed, which can express the progressively increasing strain and stiffness reduction. The analysis technique is mainly based on the modified compression field theory and scalar damage concept. which describe the strain and stress configuration in the shear zone by considering the 2-dimensional effect, and express the degradation of principal compressive strut by cyclic strain increment, secant modulus decrement, and modifying the parabolic stress strain relationship. The analysis of the response of RC beams under repeated shear-flexure loading has been carried out and compared with the experimental results. The present theory may efficiently be used to evaluate the deflection and strain accumulation under repeated loadings.

  • PDF

Behavior of FRP strengthened RC brick in-filled frames subjected to cyclic loading

  • Singh, Balvir;Chidambaram, R. Siva;Sharma, Shruti;Kwatra, Naveen
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.557-566
    • /
    • 2017
  • Fiber reinforced polymer (FRP) sheets are the most efficient structural materials in terms of strength to weight ratio and its application in strengthening and retrofitting of a structure or structural elements are inevitable. The performance enhancement of structural elements without increasing the cross sectional area and flexible nature are the major advantages of FRP in retrofitting/strengthening work. This research article presents a detailed study on the inelastic response of conventional and retrofitted Reinforced Concrete (RC) frames using Carbon Fibre Reinforced Polymers (CFRP) and Glass Fiber Reinforced Polymers (GFRP) subjected to quasi-static loading. The hysteretic behaviour, stiffness degradation, energy dissipation and damage index are the parameters employed to analyse the efficacy of FRP strengthening of brick in-filled RC frames. Repair and retrofitting of brick infilled RC frame shows an improved load carrying and damage tolerance capacity than control frame.