• Title/Summary/Keyword: cycle count

Search Result 134, Processing Time 0.027 seconds

AE Count Rate and Crack Growth Rate under Low Cycle Fatigue Fracture Loading (저주기 피로 파괴 하중하에서 AE수 변화율과 균열성장율에 관한 연구)

  • 이강용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.252-256
    • /
    • 1989
  • In the low cycle fatigue fracture testing with KS(or JIS) SS41, crack growth rate, AE count rate and J-integral range are measured to get empirical relations between crack growth rate and J-integral range, AE count rate and J-integral range as well as AE count rate and crack growth rate. All the relations are shown to be linear on the log-log graphs. It is also shown that the linear relations can be formulated by using Dunegan's assumption and elastic-plastic fracture mechanics along with the well-known relation of crack growth rate and J-integral range. It is concluded that the differences between experimental and theoretical values are due to Dunegan's assumption.

Cleaning and Storage Effect of Electrolyzed Water Manufactured by Various Electrolytic Diaphragm (격막 방식에 따라 제조한 전해수의 세척 및 보관 효과)

  • 김명호;정진웅;조영제
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.160-169
    • /
    • 2004
  • This study was carried out to investigate the efficacy of electrolyzed water manufactured with or without diaphragm on sterilization and preservation of cut-celery and shelled raw oyster. In cut-celery, total viable cell count and coliform group in the treatment of electrolyzed water were decreased to about 1/200∼1/1,000 level and about 1/100 level comparing non-treated ones. But moisture content, pH, hardness, vitamin C and residual chlorine content were showed a little difference among treatments up to 10 days at 10$^{\circ}C$. L and a color values were gradually increased in all treatments, and color differences($\Delta$E) were remarkable between treatment and untreatment sample. In overall acceptability, cut-celery treated with electrolyzed water showed somewhat higher score than that of other ones treated with tap water and 100 ppm NaClO solution until 5 days of storage. After 48 hours of storage, it was showed that VBN, total viable cell count and coliform count of shelled raw oyster treated with electrolyzed alkali water produced by non-diaphragm system are lower by about 3 mg%, 1∼2 log cycle and 2 log cycle respectively than that of ones treated with sea water. Total viable cell count of shelled raw oyster just after treatment was lower by about 1 log cycle than that of ones treated with sea water, and any significant increment was not found after 24∼48 hours of storage.

Evaluation and monitoring of degradation mechanism of Li-ion battery for portable electronic device (휴대전자기기용 저용량 리튬이온 배터리의 충방전 열화 기구 분석 및 모니터링)

  • Byeon, Jai Won
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.129-140
    • /
    • 2013
  • As a fundamental experimental study for reliability improvement of lithium ion secondary battery, degradation mechanism was investigated by microscopic observation and acoustic emission monitoring. Microstructural observation of the decomposed battery after cycle test revealed mechanical and chemical damages such as interface delamination, microcrack of the electrodes, and solid electrolyte interphase (SEI). Acoustic emission (AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Observed damages were attributed to sources of the detected AE signals.

A Performance-Oriented Intra-Prediction Hardware Design for H.264/AVC

  • Jin, Xianzhe;Ryoo, Kwangki
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • In this paper, we propose a parallel intra-operation unit and a memory architecture for improving the performance of intra-prediction, which utilizes spatial correlation in an image to predict the blocks and contains 17 prediction modes in total. The design is targeted for portable devices applying H.264/AVC decoders. For boosting the performance of the proposed design, we adopt a parallel intra-operation unit that can achieve the prediction of 16 neighboring pixels at the same time. In the best case, it can achieve the computation of one luma $16{\times}16$ block within 16 cycles. For one luma $4{\times}4$ block, a mere one cycle is needed to finish the process of computation. Compared with the previous designs, the average cycle reduction rate is 78.01%, and the gate count is slightly reduced. The design is synthesized with the MagnaChip $0.18{mu}m$ library and can run at 125 MHz.

Detection of Acoustic Signal Emitted during Degradation of Lithium Ion Battery (리튬이온전지의 열화손상에 의한 음향방출 신호 검출)

  • Choi, Chan-Yang;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.198-204
    • /
    • 2013
  • Acoustic emission(AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. AE signal was received during accelerated charge/discharge cycle test of a coin-type commercial battery. A number of AE signals were successfully detected during charge and discharge, respectively. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Microstructural observation of the decomposed battery after cycle test revealed mechanical damages such as interface delamination and microcracking of the electrodes. These damages were attributed to sources of the detected AE signals. Based on a linear correlation between discharge capacity and cumulative count, feasibility of AE technique for evaluation of battery degradation was suggested.

A New Register Allocation Technique for Performance Enhancement of Embedded Software (내장형 소프트웨어의 성능 향상을 위한 새로운 레지스터 할당 기법)

  • Jong-Yeol, Lee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.85-94
    • /
    • 2004
  • In this paper, a register allocation techlique that translates memory accesses to register accesses Is presented to enhance embedded software performance. In the proposed method, a source code is profiled to generate a memory trace. From the profiling results, target functions with high dynamic call counts are selected, and the proposed register allocation technique is applied only to the target functions to save the compilation time. The memory trace of the target functions is searched for the memory accesses that result in cycle count reduction when replaced by register accesses, and they are translated to register accesses by modifying the intermediate code and allocating Promotion registers. The experiments where the performance is measured in terms of the cycle count on MediaBench and DSPstone benchmark programs show that the proposed method increases the performance by 14% and 18% on the average for ARM and MCORE, respectively.

Effect of Hyulbuchukeotang on the Inhibition of Proliferation of Uterine leiomyoma cells and Cell apoptosis (혈부축어탕(血府逐瘀湯) 자궁근종세포의 증식억제와 Apoptosis 관련 유전자 발현에 미치는 영향)

  • Moon, Na-Young;Baek, Seung-Hee;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.2
    • /
    • pp.186-198
    • /
    • 2006
  • Purpose : The purpose of this study is to demonstrate the direct inhibitory effect of Hyulbuchukeotang on the proliferation of uterine leiomyoma cells through an experiment treating uterine leiomyoma cells cultivated by explantation with indicated concentrations of Hyulbuchukeotang and to research the gene expression related to cell cycle ill order to discover the connection with apoptosis and its mechanism by analyzing cell cycle. Methods : After primary culture of uterine leiomyoma cells, the cultivated uterine leiomyoma cells were treated with indicated concentrations of Hyulbuchukeotang for 24 hours. The inhibitory effect on the cell proliferation was determined by the cell count assay. The value of a cell count assay represent the percentage of cells in a phase of the cell cycle compared with total cells. In addition, a link between Hyulbuchukeotang and apoptosis was examined through flow cytometric analysis by FACS and DNA fragmentation analysis. Finally, the degree of gene expression related to cell cycle was evaluated by Western blot analysis. Results : The inhibitory effect of Hyulbuchukeotang increase of uterine leiomyoma cells treated with indicated concentrations of Hyulbuchkeotang increases. The result of gene expression related to G1 phase after treating with 100, 250, 500, 1,000 ${\mu}g/ml$ concentrations of Hyulbuchukeotang. on uterine leiomyoma cells is that the gene expression of p27 was increased but that of p53 an p21 remained unchanged and the gene of pRB, pro-caspase 3 was decreased. Conclusion Through the mentioned experiments, it is demonstrated that Hyulbuchkeotang is effective in inhibiting Proliferation of uterine leiomyoma cells by extending cell cycle G1. However it is not considered that the inhibitory effect results from the aptoposis.

  • PDF

Inter-ovarian differences in ultrasound markers of ovarian size in women with polycystic ovary syndrome

  • Chun, Sungwook
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.46 no.4
    • /
    • pp.197-201
    • /
    • 2019
  • Objective: The aim of this study was to establish whether differences in ovarian size exist between the right and the left ovary of the same individual in women with polycystic ovary syndrome. Methods: In total, 206 Korean women with polycystic ovary syndrome were included in this study. In all participants, a transvaginal or transrectal ultrasound examination was conducted in the early follicular phase of the menstrual cycle. Results: A significant linear correlation was found between the two ovaries with regard to antral follicle count and ovarian volume. The mean antral follicle count in the right ovary (26.75 ± 11.72) was significantly higher than that in the left ovary (23.98 ± 10.85), and the mean volume of the right ovary (11.06 ± 5.17 cm3) was significantly different from that of the left ovary (9.12 ± 4.89 cm3). Conclusion: Ovarian size is different between the right and the left ovary in women with polycystic ovary syndrome.

Effect of the Number of Nodular Grains on Low Cycle Fatigue Life in Spheroidal Graphite Cast Iron (저사이클 피로수명에 영향을 미치는 구상흑연주철의 흑연입자수의 영향)

  • Kim, Min-Gun;Lee, Byeong-Hyeon;Yoo, Byung-Ho
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.3-8
    • /
    • 2000
  • Low cycle fatigue life of spheroidal graphite cast iron is determined by the morphological parameters of internal graphite. The aim of this study is to clarify the effect of the number of nodular grain of spheroidal graphite cast iron on low cycle fatigue life. Two specimens that have identical average nodular grain size by changing nodular grain volume fraction and different number of nodular grain count was tested. In this paper, the parameter governing fatigue life through fatigue test, the number of nodular grain seriously affect fatigue life and nodular grain size is no longer governing parameter of it.

  • PDF

Update Cycle Detection Method of Control Limits using Control Chart Performance Evaluation Model (관리도 성능평가모형을 통한 관리한계선 갱신주기 탐지기법)

  • Kim, Jongwoo;Park, Cheong-Sool;Kim, Jun Seok;Kim, Sung-Shick;Baek, Jun-Geol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Statistical process control (SPC) is an important technique for monitoring and managing the manufacturing process. In spite of its easiness and effectiveness, some problematic sides of application exist such that the SPC techniques are hardly reflect the changes of the process conditions. Especially, update of control limits at the right time plays an important role in acquiring a reasonable performance of control charts. Therefore, we propose the control chart performance evaluation index (CPEI) based on count data model to monitor and manage the performance of control charts. The CPEI could indicate the degree of control chart performance and be helpful to detect the proper update cycle of control limits in real time. Experiments using real manufacturing data show that the proper update intervals are made by proposed method.