• 제목/요약/키워드: cut-off wall

검색결과 60건 처리시간 0.024초

전통 벽체 기법 변화에 관한 연구 (A Study on Changes of Traditional Wall Technique)

  • 조영민
    • 건축역사연구
    • /
    • 제23권4호
    • /
    • pp.47-56
    • /
    • 2014
  • Traditional wall is ground coat, twice plater, last plaster by such a process has made a wide variety of used materials and techniques are accordingly diverse. These traditional techniques handed down the traditional walls of the techniques, rather than coming to the lowered cut off at any moment from now when the technique is used, not knowing whether to be used. Repair and restore cultural property maintenance work, it is not only the outward form hiding inside it is a technique to keep the preservation of cultural assets can be called true. When viewed from the side walls of these conventional techniques to reveal changes in the traditional process by looking at the changes in technology with traditional techniques for cause shall be made in stock. This paper is from the late Joseon Japanese occupation of techniques ranging from traditional wall to reveal the change process to its current significance of cultural property repair method to be helped.

흡기포트 분사방식의 가솔린 엔진에서 급가속시 연료 거동에 관한 연구 (A Study on Fuel Transport Characteristics in a Port Fuel Injected Sl Engine during Transient Condition)

  • 황승환;조용석;이종화
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.20-27
    • /
    • 2003
  • In this paper, the fuel transport characteristics during transient condition was studied by using a Fast Response Flame Ionization Detector(FRFID). The quantitative measurement method for the inducted fuel mass into cylinder is studied. The inducted fuel mass into the cylinder was estimated by using calculated air-fuel ratio by hydrocarbon concentration of cylinder and air flow model. In order to estimate the transportation of injected fuel from the intake port into cylinder, the wall wetting fuel model was used. The two coefficient $\alpha$,$\beta$) of the wall-wetting fuel model was determined from the measured fuel mass that was inducted into the cylinder at the first cycle after injection cut-off To reduce an air/fuel ratio fluctuation during rapid throttle opening, the appropriate fuel injection rate was obtain from the wall wetting model with empirical coefficients. Result of air/fuel ratio control, air/fuel excursion was reduced.

수종의 버드나무과 유관속 형성층의 구조에 관한 비교연구 (Comparative Study on the Structure of Vascular Cambium in Some Salicaceae)

    • 한국자원식물학회지
    • /
    • 제11권3호
    • /
    • pp.326-334
    • /
    • 1998
  • Vascular cambium in 16 species of Salicaceae is nonstoried in all of them and is made up of fusiform and ray initials. The growth of cambial girth occurred by pseudotransverse division of fusiform initials and subsequent apical intrusive growth of daughter initials. The measurements of fusiform initials in tangerntial sections have revealed that the average length varies from 252.2-437.1${\mu}{\textrm}{m}$ in investigated species, with the maximum being in Populus euramericana and the minimum in Salix purprea var. Multinervis. The length of fusiform initials depends on the length of the tapering end wall , therefore, the longer the length of the tapering end wall, therefore, the longer the length of the taperding end wall, the longer the length of fusiform initials. Ray initials have their own size, magnitude, and frequency of occrrence in each species. The relative proportion of ray initials fall about 15.0-24.5% in Salicaceae. Shrubby species of Salix have a lower ratio of ray initials than the species which possess wider trunks. New ray initials are originated from cut off the side or the end of fusiform initials and central partition of a fusiform initials.

  • PDF

철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame)

  • 신종학;하기주;이희종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.131-139
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of RC frame structures with masonry infilled wall, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame(IFWB-1~3), cumulated energy dissipation capacities were increased by 1.35~1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame.

  • PDF

Determination of plastic concrete behavior at different strain rates to determine Cowper-Symonds constant for numerical modeling

  • Nateghi, Reza;Goshtasbi, Kamran;Nejati, Hamid Reza
    • Computers and Concrete
    • /
    • 제26권3호
    • /
    • pp.227-237
    • /
    • 2020
  • Strain rate investigations are needed to calibrate strain-rate-dependent material models and numerical codes. An appropriate material model, which considers the rate effects, need to be used for proper numerical modeling. The plastic concrete cut-off wall is a special underground structure that acts as a barrier to stop or reduce the groundwater flow. These structures might be subjected to different dynamic loads, especially earthquake. Deformability of a structure subjected to dynamic loads is a principal issue which need to be undertaken during the design phase of these structures. The characterization of plastic concrete behavior under different strain rates is essential for proper designing of cut-off walls subjected to dynamic loads. The Cowper-Symonds model, as one of the most commonly applied material models, complies well with the behavior of a plastic concretes in low to moderate strain rates and will be useful in explicit dynamics simulations. This paper aims to present the results of an experimental study on mechanical responses of one of the most useful types of plastic concrete and Cowper-Symonds constant determination procedures in a wide range of strain rate from 0.0005 to 107 (1/s). For this purpose, SHPB, uniaxial, and triaxial compression tests were done on plastic concrete samples. Based on the results of quasi-static and dynamic tests, the dynamic increase factors (DIF) of this material in different strain rates and stress state conditions were determined for calibration of the Cowper - Symonds material models.

Large deformation performance of the anti-seepage system connection part in earth core dam built on thick overburden

  • Yu, Xiang;Wang, Gan;Wang, Yuke;Du, Xueming;Qu, Yongqian
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.683-696
    • /
    • 2022
  • Dams are inevitably planned to be built on thick overburden with high permeability and deformability. The connection part between concrete cut-off wall in overburden and earth core in dam body is not only a key part of the anti-seepage system, but also a weak position. Large uneven settlement will be aroused at the concoction part. However, the interaction behavior and the scope of the connection part cannot be determined effectively. In this paper, numerical analysis of a high earth core dam built on thick overburden was carried out with large deformation FE method. The mechanical behavior of the connection part was detail studied. It can be drawn that there is little differences in dam integral deformation for different analysis method, but big differences were found at the connection part. The large deformation analysis method can reasonably describe the process that concrete wall penetrates into soil. The high plasticity clay has stronger ability to adapt to large uneven deformation which can reduce stress level, and stress state of concrete wall is also improved. The scope of high plasticity clay zone in the connection part can be determined according to stress level of soils and penetration depth of concrete wall.

3차원 흐름모델을 이용한 지하저수지의 관리에 대한 연구 (A Study of the Management of Groundwater Reservoir by Numerical Three Dimensional Flow Model)

  • 신방웅;김희성
    • 지질공학
    • /
    • 제5권3호
    • /
    • pp.289-300
    • /
    • 1995
  • 지하 저수지를 효과적으로 관리하기 위하여는 지표. 지하 수문 특성,대수층계의 수리지질 특성, 차수벽의 차수 기능을 기본 설계 단계부터 계획적으로 분석 검토하여야 한다. 본 연구에서는 국재 최초로 건설된 경북 이안 지하 저수지의 기능 분석하기 위하여 3차원 유한 차분 흐름모델을 이용하였다.지하댐 건설 후의 정류모의를 구축하였으며 그 결과 각 조건에 따른 지하 수문계의 물수지를 결정하고 안전 채수량을 제시하였다. 모의 결과 지하수위의 계절적 변동에 영향을 주는 주요인의 하나로 관개용수의 지하침투 현상이 규명되었다. 관개용수로부터 함양량은 5,6개월에는 4.3mm/d, 7,8월에는 1.7mm/d이다. 유역 산지로부터 대수층내로의 함양량은 $0.04m^3/s$로서 연중일정하며 1984년 댐의 종단면을 통한 지하수 유출량이 $0.002m^3/s$일 때 관개 기간인 7,8월 두달간 최적 양수량은 $254000m^3$이었으나, 1993년 댐의 종단면을 통한 지하수 유출량은 $0.013m^3/s$로서 차수벽의 기능은 상실되었다. 지하댐의 차수기능을 보강하지 않을 경우 관개 기간내에서의 최적 양수량은 $93,000m^3$이 된다.

  • PDF

원심모형실험을 통한 EPS 차단벽의 방진효과에 관한 연구 (A Study on the Vibration Protection Efficiency of EPS Wall Barrier with Centrifuge Model Tests)

  • 이강일
    • 한국지반공학회논문집
    • /
    • 제22권10호
    • /
    • pp.101-110
    • /
    • 2006
  • 일반적으로 환경 지반진동은 가진원과 지반내 전달, 수신부라는 전파경로를 통해 목적지에 전달된다. 그중에서도 지반내 파동의 전달은 전파의 방식이 각 지반의 특성에 따라 의존하고 있기 때문에 매우 복잡하다. 또한 이러한 전파를 효율적으로 차단하기 위해 최근 현장에서 가장 많이 적용하고 있는 공법은 방진벽이다. 그러나 이러한 방진벽 공법은 다양한 변수와 연관되어 방진효과에 영향을 미치지만 그중에서도 방진벽 재료의 선택이 가장 중요하다. 따라서 본 연구는 지표면에 충격하중이 가해졌을 경우 지반내 전달되는 전파경로를 효율적으로 차단할 수 있는 방진벽 재료인 EPS차단벽 재료에 대하여 원심모형실험을 통해 연구하였다. 이를 위하여 차단벽의 형상은 원통형과 직사각형 타입을 적용하였고 원통형 타입은 차단벽재의 타설심도를, 직사각형타입은 차단벽의 길이를 변화시키는 실험을 실시하여 이들의 차이가 방진효과에 미치는 영향에 대하여 연구하였다.

주열식 지중연속벽체의 차수효과 확인 방안 (The Method of Certificating Waterproof Effect for Consecutive Column-Wall Mass in Underground)

  • 고용일
    • 한국지반환경공학회 논문집
    • /
    • 제18권9호
    • /
    • pp.5-9
    • /
    • 2017
  • 일반적인 지하수에 대해서는 지반공학적 방법((1)지반을 굴착한 후 지중연속벽체의 육안 확인, (2)벽체의 코아 채취 후 일축압축강도시험, (3)벽체 코아 채취 시 현장 투수시험)으로 주열식 지중연속벽체의 차수효과를 확인할 수 있다. 그러나, 폐기물 매립장내에서 발생하는 침출수와 같은 고농도 오염수 유출이나 침투의 차단에 대해서는 주변 지하수 등을 대상으로 현장에서 pH, 수온, 염분 농도 등을 측정하고 이들의 성분시험을 실시하여 기본 성분 및 성분비 등의 특성을 분석한 후 일치성 유사성을 판정하며, GC-MS를 이용하여서는 이들 시료수의 크로마토그램에 대한 피크의 높고 낮음의 차이 등 전반적인 분포패턴을 비교하여 간편하게 유사성 판정을 추가적으로 실시함으로써 객관성 있게 주열식 지중연속벽체의 차수효과를 확인하여야 한다.

Pelvic Hydatidosis Mimicking a Malignant Multicystic Ovarian Tumor

  • Singh, Prem;Mushtaq, Deeba;Verma, Neetu;Mahajan, N.C.
    • Parasites, Hosts and Diseases
    • /
    • 제48권3호
    • /
    • pp.263-265
    • /
    • 2010
  • Echinococcosis is a multisystem disease and has propensity to involve any organ, an unusual anatomical site, and can mimic any disease process. Primary peritoneal echinococcosis is known to occur secondary to hepatic involvement but occasional cases of primary peritoneal hydatid disease including pelvic involvement have also been reported. We report here 1 such case of primary pelvic hydatidosis mimicking a malignant multicystic ovarian tumor where there was no evidence of involvement of the liver or spleen. Our patient, a 27-year-old female, was detected to have a large right cystic adnexal mass on per vaginal examination which was confirmed by ultrasonography. Her biochemical parameters were normal and CA-125 levels, though mildly raised, were below the cut off point. She underwent surgery and on exploratory laparotomy, another cystic mass was found attached to the mesentery of the small gut. The resected cysts were processed histopathologically. On cut sections both large cysts revealed numerous daughter cysts. Microscopic examination of fluid from the cysts revealed free scolices with hooklets and the cyst wall had a typical laminated membrane with inner germinal layer containing degenerated protoplasmic mass. The diagnosis of pelvic hydatid disease was confirmed and patient was managed accordingly. Hydatid disease must be considered while making the differential diagnosis of pelvic cystic masses, especially in endemic areas.