• 제목/요약/키워드: cut-off temperature

검색결과 140건 처리시간 0.15초

비금속관 설비관통부의 슬리브 종류에 따른 내화성능 비교 (Comparison of the Fire Resistance Performance of Firestop Systems on Non-Metallic Pipes, Based on the Type of Through-Penetration Sleeve Used)

  • 정아영;최홍범;박진오;이형도
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.301-302
    • /
    • 2023
  • In this study, we aimed to identify changes in fire resistance according to the type of sleeves used for pipe penetrations and to examine their accreditation of fire resistance performance and use them as basic data. The test results of fire resistance according to the type of sleeve used in non-metallic pipe facilities showed that the temperature on the support side was higher for sleeves with higher thermal conductivity. For the temperature on the surface of the pipes, in the case of galvanized steel plates, steel pipes, and structures without sleeves, the highest temperature was observed after the expansion of the firestop material for 46 to 53 minutes and then decreased. PVC sleeves showed a steady increase in temperature until 53 minutes, after which the temperature did not increase further. In addition, for non-metallic pipes, the effect of the type of sleeve on fire resistance is considered to be insignificant because the lower part (heating direction of the furnace) under the support structure is cut off to block the heat during the two-hour fire resistance test.

  • PDF

열가소성 가타퍼차 근관충전재료의 흐름성 특성 (Flow properties of thermoplasticized Gutta Percha obturation materials)

  • 백명현;송부석;최은미
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.311-320
    • /
    • 2018
  • 본 연구의 목적은 서로 다른 온도 설정을 받았을 때 열가소성 가타퍼차의 흐름성 특성을 평가 해보고자 현재 임상에서 사용되는 가타퍼차 4개 제품을 연질, 중질, 경질로 분류하여 실험하였으며, 실험시편은 24시간 동안 $(23{\pm}2)^{\circ}C$, ($50{\pm}5$) % 상대습도 조건으로 하여 ISO 1133-1:2011의 제시에 따라 레오미터(Melt flow indexer MFI-10, DAVENPORT, England)로 측정했다. 가타퍼차 재료의 열화 온도는 $108^{\circ}C$, $160^{\circ}C$, $200^{\circ}C$의 온도로 하고 하중은 2.16 ㎏, 3.8 ㎏으로 설정했으며 시편은 레오미터 가압과정에 적합하도록 약 5 mm 단위로 잘랐으며, Preheating time 5 분, Cutting time은 5~240초, 샘플은 10 g 으로 하여 실험한 결과 $108^{\circ}C$, $160^{\circ}C$의 온도에서는 흐름성 성질에 변화가 없었으나 $200^{\circ}C$까지 열화하면 흐름성 성질이 변화되는 것으로 나타났다. 가압 하중은 2.16 ㎏과 3.8 ㎏으로 하여 측정한 결과 하중은 흐름성 특성에 영향을 미치지 않았으나 열가소성 가타퍼차의 흐름성 측정의 경우 온도와 Cut-off time의 설정이 매우 중요한 것으로 조사 되었다.

Terahertz Generation and Detection Using InGaAs/InAlAs Multi Quantum Well

  • 박동우;한임식;노삼규;지영빈;오승재;서진석;전태인;김진수;김종수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.205-205
    • /
    • 2013
  • 테라헤르쯔(terahertz: THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지 (meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자 이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한 (low-temperature grown : LT) GaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 현재 THz 응용분야에서 보다 작고 가격경쟁력이 있는 광통신을 이용한 THz photomixer등이 활발히 연구 하고 있다. 광섬유 내에서 손실과 분산이 최소값을 가지는 부분이 1.55 ${\mu}m$ 부근이고 In0.53Ga0.47As 기판을 이용하였을 때 여기에 완벽하게 만족하게 된다. 하지만 LT-InGaAs 의 경우 AsGa antisite로 인하여 carrier lifetime은 짧아지지만 높은 n-type 전하밀도를 가지게 된다. 이때 Be을 doping하여 전하밀도를 보상하여 높은 저항을 유지해야 하는데 Be의 활성화를 위해서는 열처리를 필요로 한다. 하지만 열처리를 하면 carrier lifetime이 길어지기 때문에 carrier lifetime과 저항을 적절히 조율해야 한다. 이는 물질자체의 특성이기 때문에 InGaAs는 GaAs보다 낮은 amplitude와 짧은 cut-off frequency를 가진다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 InGaAs:Be/InAlAs multi quantum well (MQW)를 온도별 ($250{\sim}400^{\circ}C$), 주기별 (50~150)로 성장을 하였고 이때 InGaAs layer의 Be doping level은 $2{\times}1018\;cm^{-3}$, Ex-situ annealing은 $550^{\circ}C$에서 10분으로 고정 하였다. THz 발생 실험에서는 InGaAs/InAlAs MQW은 4000 pA로 1,000 pA를 가지는 InGaAs epilayer보다 4배 높은 전류 신호를 얻을 수 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. THz 검출 실험에서는 LT-InGaAs:Be epilayer LT-InGaAs:Be/InAlAs, HT-InGaAs/InAlAs 샘플이 각각 180, 9000, 12000 pA의 전류신호를 가지고 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. HT-InGaAs/InAlAs MQW를 이용한 검출실험에서는 InGaAs layer가 defect free이지만 LT-InGaAs:Be/ InAlAs MQW 보다 높은 전류 신호를 얻을 수 있었다. 이는 InAlAs layer가 저항만 높이는 것뿐만 아니라 carrier trapping layer로써의 역할도 하는 것으로 사료된다.

  • PDF

Li-ion 이차전지의 충방전 시 발열 및 충방전 특성의 CFD 모델링 (A CFD Modeling of Heat Generation and Charge-Discharge Behavior of a Li-ion Secondary Battery)

  • 강혜지;박홍범;한경호;윤도영
    • 전기화학회지
    • /
    • 제19권3호
    • /
    • pp.114-121
    • /
    • 2016
  • 본 연구에서는 리튬이온전지의 충방전시 발생하는 발열특성을 CFD 모델링하고, 발열에 따른 충방전 특성을 해석하였다. 리튬이온전지는 직교 파우치형 구조로서 두께방향으로의 1차원계로 설정하여, 전류밀도 방정식, 열 및 물질전달 지배방정식을 도입하였다. Cut-off 전압이 3 V에서 충방전 전류밀도가 1C($17.5A/m^2$), 3C($52.5A/m^2$) 와 5C($87.5A/m^2$)에 대하여, 298K의 등온계와 충방전 전류밀도 별 발열계로 각각 설정하였다. 등온계와 발열계에서 모두 충방전 전류밀도가 높을수록 전지의 용량은 감소되는 것으로 나타났다. 등온계에 비하여 발열계에서 충방전 시간이 증가하였으며, 이는 발열에 의한 온도의 증가로 인해 전극의 평형전위가 감소하고, 리튬이온의 확산계수가 증가하기 때문인 것으로 고려된다. 또한, 리튬이온전지의 충전과 방전에 의한 열 발생 영향을 제어하기 위한 냉각효과를 분석하였다.

Effect of Heat-Treat Methods on the Soluble Calcium Levels in the Commercial Milk Products

  • Yoo, Sung-Ho;Kang, Seung-Bum;Park, Jin-Ho;Lee, Kyung-Sang;Kim, Jin-Man;Yoon, Sung-Sik
    • 한국축산식품학회지
    • /
    • 제33권3호
    • /
    • pp.369-376
    • /
    • 2013
  • Milk is well known to be rich in some nutrients such as protein, calcium, phosphorus, and vitamins. In particular, absorption and bioavailability of calcium receive lots of attention because calcium is very little absorbed until it is changed to the ionized form in the intestine. In this study, concentration of the soluble calcium was determined in the commercial bovine milk products, which were processed by different heat-treatment methods for pasteurization. As for general constituents, lactose, fat, protein, and mineral were almost same in the liquid milk products by different processors. Ultrafiltration of the skimmed milk caused little change in the permeate as for lactose content but both fat and protein decreased. pH values ranges from 6.57-6.62 at room temperature and slightly increase after centrifugation, 10,000 g, 10 min. Rennet-coagulation activity was the lowest in the ultra high temperature (UHT-)milk compared to the low temperature long time (LTLT-) and high temperature short time (HTST-)milk products. Each bovine milk products contains 1056.5-1111.3 mg/kg of Ca. The content of sulfhydryl group was the lowest in raw milk compared to the commercial products tested. For the skimmed milks after ultrafiltration with a membrane (Mw cut-off, 3 Kd), soluble Ca in the raw milk was highest at 450.2 mg/kg, followed by LTLT-milk 336.4-345.1 mg/kg, HTST-milk 305.5-313.3 mg/kg, UHT-milk 370.3-380.2 mg/kg in the decreasing order. After secondary ultrafiltration with a membrane (Mw cut-off, 1 kD), total calcium in raw milk had a highest of 444.2 mg/kg, and those in the market milk products. As follow: UHT-milk, 371.3 to 378.2 mg/kg; LTLT-milk, 333.3 to 342.2 mg/kg; HTST-milk 301.9 to 311.2 mg/kg in a decreasing order.

Influence of electro-magneto-thermal environment on the wave propagation analysis of sandwich nano-beam based on nonlocal strain gradient theory and shear deformation theories

  • Arani, Ali Ghorbanpour;Pourjamshidian, Mahmoud;Arefi, Mohammad
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.329-342
    • /
    • 2017
  • In this paper, the dispersion characteristics of elastic waves propagation in sandwich nano-beams with functionally graded (FG) face-sheets reinforced with carbon nanotubes (CNTs) is investigated based on various high order shear deformation beam theories (HOSDBTs) as well as nonlocal strain gradient theory (NSGT). In order to align CNTs as symmetric and asymmetric in top and bottom face-sheets with respect to neutral geometric axis of the sandwich nano-beam, various patterns are employed in this analysis. The sandwich nano-beam resting on Pasternak foundation is subjected to thermal, magnetic and electrical fields. In order to involve small scale parameter in governing equations, the NSGT is employed for this analysis. The governing equations of motion are derived using Hamilton's principle based on various HSDBTs. Then the governing equations are solved using analytical method. A detailed parametric study is conducted to study the effects of length scale parameter, different HSDBTs, the nonlocal parameter, various aligning of CNTs in thickness direction of face-sheets, different volume fraction of CNTs, foundation stiffness, applied voltage, magnetic intensity field and temperature change on the wave propagation characteristics of sandwich nano-beam. Also cut-off frequency and phase velocity are investigated in detail. According to results obtained, UU and VA patterns have the same cut-off frequency value but AV pattern has the lower value with respect to them.

복부 수술환자의 수술부위 감염 위험 예측 도구의 타당도 검증 (Validation of the Risk Prediction Tool for Wound Infection in Abdominal Surgery Patients)

  • 정현경;이은남
    • 중환자간호학회지
    • /
    • 제15권3호
    • /
    • pp.75-87
    • /
    • 2022
  • Purpose : This retrospective investigation study aimed to determine the predictive validity of superficial surgical site infection assessment tools by measuring the risk score at the surgical site. Methods : This study included patients hospitalized to the general surgery department of a Hospital from January 2021 to December 31, 2021. The inclusion criteria were age ≥19 years, general abdominal surgery under general anesthesia, and hospital stay longer than 2 days. Patients who had undergone transplantation were excluded. Results : Tool validity results showed that tools including surgical time and operative procedure were more accurate than previously developed tools, with a sensitivity of 71.1%, specificity of 71.4%, positive prediction of 12.3%, negative prediction of 97.8%, and area under the curve of 0.743 (95% confidence interval, 0.678~0.745). The tool's cut-off score was 15, and the risks of infection was increased by 6.14 times at or above this cut-off point. Preoperative hair removal period, surgical wound classification, surgery time, body temperature on the second day after surgery, drainage tube type, and suture type affected the risk of infection at the surgical site. Conclusion : The incidence of healthcare-associated infections has been declining in the past decade; however, surgical site infections still account for a considerable proportion. Therefore, early identification of high-risk groups for surgical site infection is crucial for reducing the incidence of surgical site infection using appropriate management.

LiNbO$_3$기판 위에서의 양자교환에 의한 공도파로 제작 (Fabrication of optical waveguide on LiNbO$_3$substrate by proton exchange)

  • 정상철;심광보;정용선;신재혁;오근호
    • 한국결정성장학회지
    • /
    • 제10권4호
    • /
    • pp.297-301
    • /
    • 2000
  • H와 Li의 양자교환법에 의해 평면도파로와 channel도파로를 $LiNbO_3$단결정 기판위에 구현하였다. 양자원으로 피로인산을 사용하였고 평면도파로의 모드들에 대한 유효굴절률을 측정하였으며 반응시간과 반응온도로부터 광도파로의 깊이와 계단형 형태의 굴절률 변화에 대한 식을 구하였다. 이 식에서 구한 단일모드 도파 조건으로 channel 도파로를 제작하였고 입사광의 제한 효과를 관찰하였다.

  • PDF

측두하악장애에서의 적외선 체열 촬영 검사의 유용성 (Infrared Thermography in the Assessment of Temporomandibular Joint Dysorder)

  • 남상건;구미숙;김양현;서정훈;신화용;최용민;김용철;이상철;이평복
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.163-168
    • /
    • 2007
  • Background: Temporomandibular joint disorder (TMD) is a group of musculoskeletal conditions characterized by pain in the pre-auricular area, limitation of jaw movement and palpable muscle tenderness. Thermography is a nonionizing, noninvasive diagnostic alternative for the evaluation of TMD. This study was conducted to evaluate the usefulness of thermography in the assessment of TMD. Methods: Thermography was conducted on the 61 patients who had been diagnosed with TMD, and on the 34 normal symptom-free volunteers. The temperature differences between opposite sides of the temporomandibular joint (${\Delta}T_{TMJ}$) and the masseter muscle (${\Delta}T_{MST}$) were calculated. The sensitivity and specificity of thermography was calculated at the cut off values of 0.2, 0.3, and $0.4^{\circ}C$. Results: In the patient group, the ${\Delta}T_{TMJ}$ was $0.42{\pm}0.38^{\circ}C$ and the ${\Delta}T_{MST}$ was $0.38{\pm}0.33^{\circ}C$, whereas in the control group the ${\Delta}T_{TMJ}$ was $0.10{\pm}0.07^{\circ}C$ and the ${\Delta}T_{MST}\;0.15{\pm}0.10^{\circ}C$. In addition, the patient group demonstrated a significantly lower level of thermal symmetry than the control group (P < 0.001) in both the temporomandibular joints and the masseter muscles. The sensitivity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 67.2, 49.2, and 42.6% in the temporomandibular joint (TMJ) and 60.7, 49.2 and 37.7% in the masseter muscle, respectively. The specificity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 88.2, 100, and 100% in the TMJ and 61.8, 91.2 and 100% in the masseter muscles, respectively. The accuracy of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 74.7, 67.4, and 63.2% in TMJ and 61.1, 64.2 and 60.0% in the masseter muscles, respectively. Conclusions: Temperature differences exist between the opposite sides of the TMD and masseter muscles in patients with TMD. Although the sensitivity of thermography in the diagnosis of TMD is low, it has high specificity in the evaluation of TMD, and is therefore applicable to patients with TMD.

Simulation of 4H-SiC MESFET for High Power and High Frequency Response

  • Chattopadhyay, S.N.;Pandey, P.;Overton, C.B.;Krishnamoorthy, S.;Leong, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권3호
    • /
    • pp.251-263
    • /
    • 2008
  • In this paper, we report an analytical modeling and 2-D Synopsys Sentaurus TCAD simulation of ion implanted silicon carbide MESFETs. The model has been developed to obtain the threshold voltage, drain-source current, intrinsic parameters such as, gate capacitance, drain-source resistance and transconductance considering different fabrication parameters such as ion dose, ion energy, ion range and annealing effect parameters. The model is useful in determining the ion implantation fabrication parameters from the optimization of the active implanted channel thickness for different ion doses resulting in the desired pinch off voltage needed for high drain current and high breakdown voltage. The drain current of approximately 10 A obtained from the analytical model agrees well with that of the Synopsys Sentaurus TCAD simulation and the breakdown voltage approximately 85 V obtained from the TCAD simulation agrees well with published experimental results. The gate-to-source capacitance and gate-to-drain capacitance, drain-source resistance and trans-conductance were studied to understand the device frequency response. Cut off and maximum frequencies of approximately 10 GHz and 29 GHz respectively were obtained from Sentaurus TCAD and verified by the Smith's chart.