• 제목/요약/키워드: cut-off low

검색결과 376건 처리시간 0.025초

저압용 누전차단기의 차단특성 및 그라파이트 분석에 관한 연구 (A Study on the Cut Off Characteristics and Graphite Analysis of Residual Current Protective Devices for Low Voltage)

  • 최충석;이경섭;정재희;박수홍;김병수;이덕출
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.49-54
    • /
    • 1999
  • In this paper. we studied cut off characteristics and fire hazard of residual current protective devices(RCD or ELB) for low voltage. The operative time of RCD with grounding resistance was analyzed by using RCD operating tester. The surface structure and composition of insulator were analyzed by using scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of phenol resin showed network structure and void. The spectra shown in EDX analysis are composed not only of the corresponding elements but also of several new spectra, as CK. OK$\alpha$. MgK, SiK. and CaK, which were absent in original material.

  • PDF

부모의 원가족 분화수준과 자녀양육행동과의 관계 (Level of parental differentiation from family of origin : relationship to child-rearing behaviors)

  • 정문자;최난경
    • 아동학회지
    • /
    • 제25권3호
    • /
    • pp.87-99
    • /
    • 2004
  • The subjects of this investigation were 393 fourth and fifth graders from two elementary schools in Seoul and parents of these children. The level of fathers' emotional separation from the family of origin was higher than that of mothers'. Mothers were more warm acceptant and rejective restrictive than fathers; fathers were more permissive neglectful than mothers. Both fathers and mothers were more rejective restrictive of girls than of boys. Mothers with high scores in emotional separation from family of origin were more warm acceptant to their children and less rejective restrictive than those with low scores. Fathers with high scores in emotional cut off from the family of origin were more permissive neglectful behavior of their children than fathers with low scores.

  • PDF

16Kbps와 40Kbps의 Dual Rate G.723 ADPCM 음성 codec 구현 (Implementation of Dual Rate G.723 ADPCM Speech codec)

  • 김재오;한경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2480-2482
    • /
    • 1998
  • In this paper, the implementation of dual rate ADPCM using G.723 16Kbps and 40Kbps speech codec algorithm is handled. For small signals, the low rate 16Kbps coding algorithm shows the same SNR as the high rate 40Kbps coding algorithm, while the low rate 16Kbps coding algorithm shows the lower SNR than the high rate 40Kbps coding algorithm for large signal. To obtain the good trade-off between the data rate and synthesized speech quality, we applied low rate 16Kbps for the small signal and high rate 40Kbps for the large signal. Various threshold values determining the rate are tested for good trade off data rate and speech quality. Also the low pass filter effect of speech input and output devices is simulated at several cut-off frequencies. To simulation result shows the good speech quality at a low rate comparing with 16Kbps & 40Kbps.

  • PDF

위성방송 수신용 소형 반사면 안테나의 절단 크기에 따른 성능지수의 분석 (An Analysis of the Figure of Merit depending on the cut-off size of a Small Reflector for Satellite Broadcast Receiving Antenna)

  • 임계재
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.152-155
    • /
    • 2013
  • 본 논문은 위성방송 수신용 소형 파라볼라 안테나의 높이를 보다 낮추기 위하여 반사면의 상하 부분을 부분적으로 절단하였을 때 나타나는 spill-over 의 증가로 인한 성능지수의 저하를 분석하였다. 또한 안테나를 고도각 0도부터 60도까지 트래킹하는 경우에 측엽과 후엽이 받는 대지면 열잡음의 증가로 인한 잡음온도의 영향을 고려하고, LNA 의 잡음지수로 인한 총 잡음온도의 증가 영향을 고려하여 성능지수 값을 시뮬레이션하여 그 결과를 분석하였다. 분석 결과, 원형 파라볼라의 반사면 상하부분을 35% 절단하였을 때, 잡음온도는 약 15K 정도 증가하였으며, G/T 비는 2.5dB 정도 저하하였다.

Enhancement of Ozone and Carbon Monoxide Associated with Upper Cut-off Low during Springtime in East Asia

  • Moon, Yun-Seob;Drummond, James R.
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.475-489
    • /
    • 2010
  • In order to verify the enhancement of ozone and carbon monoxide (CO) during springtime in East Asia, we investigated weather conditions and data from remote sensors, air quality models, and air quality monitors. These include the geopotential height archived from the final (FNL) meteorological field, the potential vorticity and the wind velocity simulated by the Meteorological Mesoscale Model 5 (MM5), the back trajectory estimated by the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, the total column amount of ozone and the aerosol index retrieved from the Total Ozone Mapping Spectrometer (TOMS), the total column density of CO retrieved from the Measurement of Pollution in the Troposphere (MOPITT), and the concentration of ozone and CO simulated by the Model for Ozone and Related Chemical Tracers (MOZART). In particular, the total column density of CO, which mightoriginate from the combustion of fossil fuels and the burning of biomass in China, increased in East Asia during spring 2000. In addition, the enhancement of total column amounts of ozone and CO appeared to be associated with both the upper cut-off low near 500 hPa and the frontogenesis of a surface cyclone during a weak Asian dust event. At the same time, high concentrations of ozone and CO on the Earth's surface were shown at the Seoul air quality monitoring site, located at the surface frontogenesis in Korea. It was clear that the ozone was invaded by the downward stretched vortex anomalies, which included the ozone-rich airflow, during movement and development of the cut-off low, and then there was the catalytic photochemical reaction of ozone precursors on the Earth's surface during the day. In addition, air pollutants such as CO and aerosol were tracked along both the cyclone vortex and the strong westerly as shown at the back trajectory in Seoul and Busan, respectively. Consequently, the maxima of ozone and CO between the two areas showed up differently because of the time lag between those gases, including their catalytic photochemical reactions together with the invasion from the upper troposphere, as well as the path of their transport from China during the weak Asian dust event.

대역통과필터를 이용한 직렬아크 검출에 관한 연구 (A Study on Series Arc Detection Using Band-pass Filters)

  • 김일권;김진수;박건우;김광순;김영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1345-1347
    • /
    • 2008
  • This paper described a method of determining whether arcing is present in a low-voltage wiring system. We simulated the series arcing that generated in electrical loads and fabricated a arc detection module which can discriminate between normal and arcing state. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage and an active band-pass filter with a frequency of 4 kHz ${\sim}$ 8 kHz to detect series arc signals only. We tested an Incandescent lamp that was controlled by a dimmer and analysed. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. From the experimental results, we could detect series arc signals without an influence of non-linear loads.

  • PDF

Analysis of Novel Approach to Design of Ultra-wide Stopband Microstrip Low-Pass Filter Using Modified U-Shaped Resonator

  • Karimi, Gholamreza;Lalbakhsh, Ali;Dehghani, Khatereh;Siahkamari, Hesam
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.945-950
    • /
    • 2015
  • A novel microstrip low-pass filter is presented to achieve an ultra-wide stopband with 11 harmonic suppression and very sharp skirt characteristics. The filter is composed of a modified U-shaped resonator (which creates two fully adjustable transmission zeroes), a T-shaped resonator (which determines a cut-off frequency), and four radial stubs (which provide a wider stopband). The operating mechanism of the filter is investigated based on a proposed equivalent-circuit model, and the role of each section of the proposed filter in creating null points is theoretically discussed in detail. The presented filter with 3 dB cut-off frequency ($f_c=2.35GHz$) has been fabricated and measured. Results show that a relative stopband bandwidth of 164% (referred to as a 22 dB suppression) is obtained while achieving a high figure-of-merit of 15,221.

분광 반사법을 이용한 GaN 박막의 실시간 관찰 (In-situ Monitoring of GaN Epilayers by Spectral Reflectance)

  • 나현석
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.361-366
    • /
    • 2011
  • 본 연구에서는 분광 반사 측정용으로 개조된 metalorganic chemical vapor deposition를 이용하여 GaN의 성장을 반응기 내부에서 실시간으로 관찰하였다. 분광 반사법에서는 190~861 nm의 p-편광된 빛을 시편에 $75^{\circ}$로 입사시킨 후 뒤 GaN 박막으로부터 반사되어 나오는 빛을 분석한다. 관찰된 반사 스펙트럼은 다중반사로 인하여 간섭현상도 함께 보여주고 있는데, 이때 위아래로 진동하는 폭은 박막의 결정성이 나쁘면 줄어들었고, 이는 박막 내부에 존재하는 많은 결함에 의해 입사된 빛이 산란되거나 흡수되어 전체적으로 반사강도가 크게 감소하였기 때문으로 판단된다. 또한 가장 강한 보강간섭을 나타내는 파장을 선택하여 $NH_3$의 공급여부에 따른 강도변화를 실시간을 관찰하였는데, 10초 차단한 경우에는 큰 변화는 없었지만, 30초 이상인 경우에는 뚜렷한 강도 증가가 관찰되었고, 계속 차단하였을 때도 높아진 강도로 계속 유지되었다. 이러한 현상은 $NH_3$를 공급했을 때 표면은 N로 덮여 있었지만, $NH_3$ 공급을 차단하면 GaN의 높은 질소평형증기압으로 인하여 표면의 질소가 탈착되어 표면은 금속성의 Ga으로 덮인 상태로 바뀌었기 때문에 반사강도가 약간 상승한 것으로 보인다.

연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화 (The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers)

  • 김용배;안현철;황보영;리갑수;이성수;안규동;이병국
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

가변 필터 관측기를 이용한 IPMSM 센서리스 제어 (Sensorless Control for Interior Permanent Magnet Synchronous Motor (IPMSM) using Disturbance Observer with Variable Cut-off Frequency)

  • 이준호;이화춘;이성호;정태욱;박성준
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2011
  • Using sensors to detect current or voltage of motors is disadvantaged because motor is exposed to vibration, impacts, corrosion, high temperature and humidity in the machinery structure like HEV. In the case of IPMSM, position information is included not only in the flux or EMF term but also in the rotator inductance because of its saliency. To solve this problem, a new mathematical model of IPMSMs on fixed frame is proposed and an extended EMF includiing rotating position information is defined to estimate extended EMF. A strong low-pass filter through the variable cut-off frequency using velocity function was proposed. This makes it is possible to estimate extended EMF by least order disturbance observer. The proposed method was proved through the experiment.