• Title/Summary/Keyword: cut-off low

Search Result 376, Processing Time 0.025 seconds

A Study on Low-Pass Filter using All-Pass Filter of Parallel Structure (병렬 구조의 올패스 필터를 사용한 LPF에 관한 연구)

  • 김승영;김남호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.533-541
    • /
    • 2001
  • In this paper, we proposed lowpass filter using all-pass sums of flat delay characteristics. this filter consisted of all-pass filter of parallel structure, the general analog filter is impossible to adjust the phase and the delay, using the Proposed filter, it has advantage to adjust them. And, we compared and analyzed this filter with passband width and magnitude characteristics, and the relation of group delay characteristics and cut-off frequency. Also, in order to obtain desired cut-off frequency, forming the weighing, we obtained desired cut-off frequency and group delay characteristics.

  • PDF

Numerical Simulation of Impactor Collection Efficiency according to Altitude (대기 고도에 따른 입자 포집용 관성 임팩터의 설계 및 포집효율 예측)

  • Kim, Gyuho;Yook, Se-Jin;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, the collection efficiency of inertial impactors was numerically simulated by employing the statistical Lagrangian particle tracking(SLPT) model. The SLPT model was proven to be correct in predicting the impactor collection efficiency, when the numerically obtained collection efficiencies were compared with the experimental data of Marple et al.(1987) at normal pressure level and the experimental data of $Marjam{\ddot{a}}ki$ et al.(2000) at low pressure level. Based on the validation results, balloon-borne impactors with the cut-off sizes of $1{\mu}m$, $2.5{\mu}m$, and $10{\mu}m$ were designed. Then, the sampling flowrates of the inertial impactors, required to keep the cut-off sizes constant at different pressures and temperatures, were estimated according to the altitude.

A New Broadband Microstrip-to-SIW Transition Using Parallel HMSIW

  • Cho, Dae-Keun;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2012
  • In this work, a new microstrip-to-substrate integrated waveguide (SIW) transition using the parallel half-mode substrate integrated waveguide (HMSIW) is proposed. The proposed transition consists of three sections : a microstrip, parallel HMSIWs, and an SIW. By inserting the parallel HMSIWs section between the microstrip section and the SIW section, the proposed transition can improve the return loss characteristics of the near cut-off frequency because the HMSIWs section has a lower cut-off frequency than the SIW section (8.6 GHz). The lower cut-off frequency is achieved through gradual electromagnetic field mode changes for a low reflection. The measured return loss is less than 20 dB in the of 9.1~16.28 GHz freqeuncy range for the back-to-back transition. The measured insertion loss is within 1.6 dB for the back-to-back transition. The proposed transition is expected to play an important role in wideband SIW circuits fed by a microstrip.

Fractional-order LβCα Low-Pass Filter Circuit

  • Zhou, Rui;Zhang, Run-Fan;Chen, Di-Yi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1597-1609
    • /
    • 2015
  • This paper introduces the fundamentals of the conventional LC low-pass filter circuit in the fractional domain. First, we study the new fundamentals of fractional-order LC low-pass filter circuit including the pure real angular frequency, the pure imaginary angular frequency and the short circuit angular frequency. Moreover, sensitivity analysis of the impedance characteristics and phase characteristics of the LC low-pass filter circuit with respect to the system variables is studied in detail, which shows the greater flexibility of the fractional-order filter circuit in designs. Furthermore, from the filtering property perspective, we systematically investigate the effects of the system variables (LC, frequency f and fractional orders) on the amplitude-frequency characteristics and phase-frequency characteristics. In addition, the detailed analyses of the cut-off frequency and filter factor are presented. Numerical experimental results are presented to verify the theoretical results introduced in this paper.

Design and Fabrication of a Coaxial-type Transient Voltage Suppressor for Antenna Protection on Shipboard (선박 통신 안테나용 뇌방호장치의 설계 및 제작)

  • Han, Ju-Seop;Song, Jae-Yong;Kim, Il-Kwon;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1166-1169
    • /
    • 2005
  • This paper describes a new transient voltage suppressor(TVS) with a low insertion loss and a high cut-off frequency to protect antenna circuit from transient voltages. Conventional protection devices have some problems such as a low frequency bandwidth and a high insertion loss. In order to improve these limitations, a coaxal type TVS, which consists of a gas tube is developed. The performance of the proposed transient voltage suppressor is tested by using a combination surge generator specified in IEC 61000-4-5 standard and by using a network analyzer of 40 MHz ${\sim}$ 5 GHz bandwidth. From the experimental results, it is confirmed that the proposed TVS has an enough protection performance in a low insertion loss and a high cut-off frequency.

  • PDF

The Value of Preoperative CA 125 Levels in Prediction of Myometrial Invasion in Patients with Early-stage Endometrioid-type Endometrial Cancer

  • Atguden, Zeynep;Yildiz, Askin;Aksut, Hayri;Yalcin, Serenat Eris;Yalcin, Yakup;Uysal, Dilek;Yetimalar, Hakan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.497-501
    • /
    • 2016
  • Aim: To evaluate the relationship between pre-operative CA-125 levels and myometrial invasion in patients with early-stage endometrioid-type endometrial cancer. Materials and Methods: Two-hundred and sixty patients were diagnosed with endometrial cancer between January 2007 and December 2012. Of these, 136 patients with stage 1 endometrioid histologic-type and documented pre-operative serum CA-125 levels were included in the study. Age, preoperative CA-125 level, histologic grade, surgical grade, and presence of deep myometrial invasion were recorded. Additionally, 16, 20, and 35 IU/ml cutoff values were used and compared to evaluate the relationship between pre-operative CA-125 levels and myometrial invasion. Results: The average serum CA-125 level was $35.4{\pm}36.7$ in patients with deep myometrial invasion, and $21.5{\pm}35.8$ in cases without deep myometrial invasion. The relationship between the presence of deep myometrial invasion and CA-125 cut-off values (16, 20, 35 IU/ml) was statistically significant, although the correlation was weak (p<0.05). When the relationship between 16, 20 and 35 IU/ml CA-125 cut-off values and the presence of deep myometrial invasion was studied, specifity and sensitivity values were identified as: 0.60-0.68 for 16 IU/ml; 0.73-0.48 for 20 IU/ml; and 0.89-0.33 for 35 IU/ml. The sensitivity of 16 IU/ml cut-off value was higher when compared to other values. Conclusions: This study demonstrates that preoperative serum CA-125 values maybe used as a predictive test in patients with early stage endometrioid-type endometrium cancer, and as a prognostic factor alone. Further studies should be conducted to identify different CA-125 cut-off values in patients with low risk endometrial cancer.

Asian Dust Transport during Blocking Episode Days over Korea

  • Moon, Yun-Seob;Kim, berly-Strong;Kim, Yoo-Keun;Lim, Yun-Kyu;Oh, In-Bo;Song, Sang-Keun;Bae, Joo-Hyon
    • Journal of Environmental Science International
    • /
    • v.11 no.2
    • /
    • pp.111-120
    • /
    • 2002
  • Asian dust(or yellow sand) occurs mainly in spring and occasionally in winter in east Asia, when the weather conditions are under an upper trough/cut-off low and surface high/low pressure system during blocking episode days associated with the stationary patterns of the upper level jet stream. The transport mechanism for Asian dust during the blocking episode days in spring 2001 was analyzed using the TOMS aerosol index and meteorological mesoscale model 5(MM5). Based on the E vector, an extension of an Eliassen-Palm flux, the blocking episode days were found to be associated with the development of an upper cut-off low and surface cyclones. Concurrently, the occurrence of dust storms was also determined by strong cold advection at the rear of a jet streak, which exhibited a maximum wind speed within the upper jet stream. As such, the transport mechanism for Asian dust from China was due to advection of the isentropic potential vorticity(IPV) and isentropic surfaces associated with tropopause folding. The transport heights for Asian dust during the blocking episode days were found to be associated with the distribution of the isentropes below the IPV At the same time, lee waves propagated by topography affected the downward motion and blocking of Asian dust in China. The Asian dust transported from the dust source regions was deposited by fallout and rain-out with a reinforcing frontogenesis within a surface cyclone, as determined from satellite images using TOMS and GMS5. Accordingly, these results emphasize the importance of forecasting jet streaks, the IPV, and isentropes with geopotential heights in east Asia.

Low-income Households' Experiences and Perception of Home Energy Cost Burdens in Cheongju, South Korea (청주시 저소득 가구의 가정 에너지 비용 부담 경험과 인식)

  • Lee, Hyun-Jeong
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.79-87
    • /
    • 2015
  • This study explored low-income households' experiences and perception of home energy cost burdens and determinants of the perceived home energy cost burdens. Between March and July 2014, a questionnaire survey was administered in Cheongju, South Korea. Among the 434 useable responses collected, responses from 218 households with monthly income less than 2,500,000 Korean Won (KRW) were compared with those of 216 households with higher incomes. The main findings are as follows. In the past three years, more than 10 percent of low-income households had had their electricity cut off; 5.7 percent had had their city gas cut off. To pay for their home energy expenses, nearly 70 percent of the low-income households had had to limit their heating, cooling or spending for other necessities; 38.3 percent had to borrow money. Low-income households reported more problems paying for home energy than higher-income households did. Households with more negative evaluation of rainwater leak, no one staying at home all day, monthly income less than 1,500,000 KRW and householders in their 40s and 50s tended to perceive a heavier home energy cost burden. Finally, the most popular support programs were fuel assistance and discounts on energy bills.

High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation (DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법)

  • Baek, Min-Woo;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

Suggestion of Cutoff Frequency in the Washout Filter for a Wheel type Excavator (주행감각 재현을 위한 휠굴삭기용 Washout 필터 설계 및 한계값 추정)

  • Kim, Kwang-Suk;Yoo, Wan-Suk;Lee, Min-Cheol;Son, Kown;Lee, Jang-Myung;Choi, Dae-Hyoung;Park, Min-Gyu;Park, Hyoung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.19-28
    • /
    • 1999
  • In this study, a real-time simulation system and a washout algorithm for an excavator have been developed for a driving simulator with six degrees of freedom. The excavator model consisting of a boom. bucket, upper frame, lower frame and four wheels, has total 11 degrees of freedom. The suggested washout algorithm consists of high and low pass filters with second order. The high pass filters cut off low frequency of the motion cues limited by platform motion. The cut off frequency for the tilt coordination are suggested for a realistic regeneration of excavator motion.

  • PDF