• Title/Summary/Keyword: cut-off function

Search Result 153, Processing Time 0.029 seconds

The Normative Study of the Montreal Cognitive Assessment-Korea (MoCA-K) as Instrument for Screening of Mild Cognitive Impairment (MCI) (경도인지장애 선별검사로서 Montreal Cognitive Assessment-Korea (MoCA-K)의 규준 연구)

  • Kwak, Ho-Soung;Kim, Sun-Ho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.37-45
    • /
    • 2021
  • Purpose : This study aimed to present normative data and cut-off points for older Korean adults completing the Montreal Cognitive Assessment - Korean (MoCA-K), which is used as a screening test for mild cognitive impairment in Korea. Methods : A total of 195 healthy adults ≥60 years were recruited. All participants completed the MoCA-K and the Korean - Mini-Mental State Examination (MMSE-K) to assess their cognitive function. Participants were divided into six groups based on their age: 60-64 years, 65~69 years, 70~74 years, 75~79 years, 80~84 years, and 85~89 years. Results : The results revealed that MoCA-K score decreased significantly with age (mean score ± standard deviation [SD]; 27.63±2.80 in subjects aged 60~64 years; 27.00±2.39 in subjects aged 65~69 years; 24.94±2.96 in subjects aged 70~74 years; 24.74±3.37 in subjects aged 75~79 years; 22.59±4.72 in subjects aged 80~84 years; and 18.83±5.38 in subjects aged 85~89 years; p<.001). Additionally, MoCA-K score also increased significantly with educational level (mean score±standard deviation [SD]; 19.95±4.78 in no formal education group; 24.95±2.22 in elementary school graduated group; 26.35±2.72 in middle school graduated group; 28.32±1.36 in high school graduated group; and 28.50±1.51 in more than college graduated group; p<.001). The optimal cut-off points were 24/25 for 60~69 years old group, 21/22 for 70~79 years old group, 17/18 for 80~84 years old group, and 13/14 for 85~89 years old group. The optimal cut-off points were 15/16 for individuals who were illiterate, 22/23 for individuals with 6 years of education, 22/24 for individuals with 9 years of education, and 26/27 for individuals with 12 or more years of education. Conclusions : This study presents normative data and cut-off points for the MoCA-K in older Korean adults. This data will facilitate more accurate detection and follow-up of the risk of mild cognitive impairment in this population, taking into consideration age and education. Future studies are required that should focus on the cut-off score on the level of education according to age.

Reevaluation of the Neonatal Screening Test for Congenital Hypothyroidism (선천성 갑상선기능저하증에 대한 신생아 선별검사의 재평가)

  • Kang, So Young;Chang, Young Pyo;Yu, Jeesuk
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.387-394
    • /
    • 2005
  • Purpose : We performed this study to compare the TSH and free $T_4$ levels according to gestational age and birth weight, and to reevaluate the cut-off values in the neonatal screening test for congenital hypothyroidism. Methods : Total 2,133 neonates(1,749 healthy newborns and 384 sick neonates) were screened in Dankook University Hospital from May 2000 to January 2003. Neonates with abnormal TSH values (higher than $20{\mu}IU/mL$) or abnormal free $T_4$ levels(lower than 1 ng/dL) were recalled to recheck the thyroid function test. At that time, physical examinations and history-taking regarding perinatal problem, medication history, and mother's illness were undertaken. Results : Serum TSH and free $T_4$ values revealed no significant difference according to sex, delivery type, and Apgar score. The free $T_4$ levels showed statistically significant differences, with gestational age or birth weight(P<0.01). The recall rate of neonates due to abnormal screening test was 7.48 percent. Compared with original cut-off values, the recall rate of the new cut-off values setted to TSH higher than $20{\mu}IU/mL$ or free $T_4$ lower than 0.64 ng/dL decreased from 7.48 percent to 4.8 percent in the healthy group. But, it compromised sensitivity when applied to the sick group. Conclusion : In this study, neonatal free $T_4$ levels were significantly different according to birth weight, gestational age, and the presence of compromised condition. Although the recall rate by TSH > $20{\mu}IU/mL$ or free $T_4$ <1 ng/dL was relatively high, it was impossible to set up new cut-off values without compromising sensitivity. We think studies including a larger study population will be required to change the cut-off values.

A Composite Estimator for Cut-off Sampling using Cost Function (절사표본 설계에서 비용함수를 고려한 복합추정량)

  • Sim, Hyo-Seon;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.1
    • /
    • pp.43-59
    • /
    • 2014
  • Cut-off sampling has been widely used for a highly skewed population like a business survey by discarding a part of the population, so called a take-nothing stratum. For a more accurate estimate of the population total, Hwang and Shin (2013) suggested a composite estimator of a take-nothing stratum total that combined the survey results of a take-nothing stratum and a take-some sub-stratum (a part of take-some stratum). In this paper we propose a new cut-off sampling scheme by considering a cost function and a composite estimator based on the proposed sampling scheme. Small simulation studies compared the performances of known composite estimators and the new composite estimator suggested in this study. We also use Briquette Consumption Survey data for real data analysis.

A NOTE ON A FINITE ELEMENT METHOD DEALING WITH CORNER SINGULARITIES

  • Kim, Seok-Chan;Woo, Gyung-Soo;Park, Tae-Hoon
    • Journal of applied mathematics & informatics
    • /
    • v.7 no.2
    • /
    • pp.493-506
    • /
    • 2000
  • Recently the first author and his coworker report a new finite element method for the Poisson equations with homogeneous Dirichlet boundary conditions on a polygonal domain with one re-entrant angle [7], They use the well-known fact that the solution of such problem has a singular representation, deduced a well-posed new variational problem for a regular part of solution and an extraction formula for the so-called stress intensity factor using tow cut-off functions. They use Fredholm alternative an Garding's inequality to establish the well-posedness of the variational problem and finite element approximation, so there is a maximum bound for mesh h theoretically. although the numerical experiments shows the convergence for every reasonable h with reasonable size y imposing a restriction to the support of the extra cut-off function without using Garding's inequality. We also give error analysis with similar results.

Sensorless Control for Interior Permanent Magnet Synchronous Motor (IPMSM) using Disturbance Observer with Variable Cut-off Frequency (가변 필터 관측기를 이용한 IPMSM 센서리스 제어)

  • Lee, Jun-Ho;Lee, Hwa-Choon;Lee, Sung-Ho;Jung, Tae-Uk;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • Using sensors to detect current or voltage of motors is disadvantaged because motor is exposed to vibration, impacts, corrosion, high temperature and humidity in the machinery structure like HEV. In the case of IPMSM, position information is included not only in the flux or EMF term but also in the rotator inductance because of its saliency. To solve this problem, a new mathematical model of IPMSMs on fixed frame is proposed and an extended EMF includiing rotating position information is defined to estimate extended EMF. A strong low-pass filter through the variable cut-off frequency using velocity function was proposed. This makes it is possible to estimate extended EMF by least order disturbance observer. The proposed method was proved through the experiment.

Design and Implementation of a Motor Power Change Speed Device for Micro-controller (Micro-controller 방식에 의한 Motor Power 변속장치의 설계와 구현)

  • 김정래
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.3
    • /
    • pp.163-169
    • /
    • 2003
  • This study was carried out develope a motor power change speed device of motor by used micro- controller. This system was producted a auto-change speed device which switching frequency was 1,000MHz by used a auto- controller. It had a continuous output current such as 5A, 11A, 25A, 35A, 50A. It used a variable voltage from 9V to 18V(Maximum). We designed hardware of and software of micro-controller, we are made up of a auto cut-off function by 3.7V for detected power-loss prevention.

  • PDF

Modal acoustic power of broadband noise by interaction of a cascade of flat-plate airfoils with inflow turbulence (평판 에어포일 캐스케이드와 입사 난류의 상호작용에 의한 광대역 소음의 모달 음향 파워)

  • Cheong, Cheol-Ung;Jurdic, Vincent;Joseph, Phillip
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1467-1475
    • /
    • 2007
  • This paper investigates the modal acoustic power by a cascade of flat-plate airfoils interacting with homogeneous, isotropic turbulence. Basic formulation for the acoustic power upstream and downstream is based on the analytical theory of Smith and its generalization due to Cheong et al. The acoustic power spectrum has been expressed as the sum of cut-on acoustic modes, whose modal power is the product of three terms: a turbulence series, an upstream or downstream power factor and an upstream or downstream acoustic response function. The effect of these terms in the modal acoustic power has been examined. For isotropic turbulence gust, the turbulent series are only reducing factor of the modal acoustic power. The power factor tends to reduce the modal acoustic power in the upstream direction, although the power factor is liable to increase the modal acoustic power in the downstream direction. The modes close to cut-off are decreasing strongly, especially in the downstream direction. Therefore the modes close to cut-off don't contribute highly to the radiated acoustic power in the downstream direction, although the modal acoustic pressure is high for these modes.

  • PDF

Characteristics of Modal Acoustic Power of Broadband Noise by Interaction of a Cascade of Flat-plate Airfoils with Inflow Turbulence (평판 에어포일 캐스케이드와 입사 난류의 상호작용에 의한 광대역 소음의 모달 음향 파워 특성)

  • Cheong, Cheol-Ung;Jurdic, Vincent;Joseph, Phillip
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This paper investigates the modal acoustic power by a cascade of flat-plate airfoils interacting with homogeneous, isotropic turbulence. Basic formulation for the acoustic power upstream and downstream is based on the analytical theory of Smith and its generalization due to Cheong et al. The acoustic power spectrum has been expressed as the sum of cut-on acoustic modes, whose modal power is the product of three terms: a turbulence series, an upstream or downstream power factor and an upstream or downstream acoustic response function. The effect of these terms in the modal acoustic power has been examined. For isotropic turbulence gust, the turbulent series are only reducing factor of the modal acoustic power. The power factor tends to reduce the modal acoustic power in the upstream direction, although the power factor is liable to increase the modal acoustic power in the downstream direction. The modes close to cut-off are decreasing strongly, especially in the downstream direction. Therefore the modes close to cut-off don't contribute highly to the radiated acoustic power in the downstream direction, although the modal acoustic pressure is high for these modes.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Role of Bedside Ultrasonography in Assessment of Diaphragm Function as a Predictor of Success of Weaning in Mechanically Ventilated Patients

  • Elshazly, Mostafa Ibrahim;Kamel, Khaled Mahmoud;Elkorashy, Reem Ibrahim;Ismail, Mohamed Said;Ismail, Jumana Hesham;Assal, Hebatallah Hany
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.4
    • /
    • pp.295-302
    • /
    • 2020
  • Background: Weaning failure is common in mechanically ventilated patients, and if ultrasound can predict weaning outcome remains controversial. The purpose of this study was to evaluate the diaphragmatic function (thickness and excursion) measured by ultrasound as a predictor of the extubation outcome. Methods: We included 62 mechanically ventilated patients from the chest intensive care unit in this study. Sixty-two patients who successfully passed the spontaneous breathing trial (SBT) were enrolled. The transthoracic ultrasound of the diaphragm was performed during an SBT to the assess diaphragmatic function (excursion and thickness), and they were classified into the successful extubation group and the failed extubation group. Results: There was a statistically significant increase in the successful extubation group in the diaphragmatic excursion and thickness fraction (p<0.001), a statistically significant negative correlation between the diaphragmatic function and the duration of the mechanical ventilation, and a statistically significant negative correlation between the diaphragmatic excursion and the Acute Physiology and Chronic Health Evaluation II. The diaphragmatic excursion cut-off value predictive of weaning was 1.25 cm, with a specificity of 82.1% and a sensitivity of 97.1% respectively, and the diaphragmatic thickness cut-off value predictive of weaning was 21.5%, with a specificity of 60.7% and a sensitivity of 91.2%, respectively. Conclusion: The diaphragmatic ultrasonography was found to be a promising tool for predicting the extubation outcome for mechanically ventilated patients.