• Title/Summary/Keyword: cut off level

Search Result 308, Processing Time 0.027 seconds

An experimental study for reduction of B.P.F. noise level of multi-blade fan (다익 송풍기의 이산 주파수 소음 저감을 위한 실험적 연구)

  • 김영찬;이상환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • B.P.F.(Blade Passing Frequency) levels were measured with the cut-off clearance changes. The velocity inside the scroll, pressure fluctuation at cut-off region, and the scroll surface pressure distribution along the scroll from the cut-off to outlet were measured. With a certain cut-off clearance the improvement of efficiency and attenuation of B.P.F. noise level could be achieved. The measured results of pressure fluctuation and scroll surface pressure distribution showed that the secondary flow inside the scroll increased B.P.F. noise level at the cut-off region as the cut-off clearance got wide.

  • PDF

A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera (SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2003
  • Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency supression by chosing a cut of frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimam cut off level with comparison of FWHM according to cut off level in each kiters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with $^{99m}TcO_4$ point source and measured FWHM by use profile curve. We find averaged length is $9.16\;mm{\sim}18.14\;mm$ of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  • PDF

Comparison and Evaluation of Hematological Indices for Assessment of Iron Nutritional Status in Korean Pregnant Women(III) (우리나라 임신부의 혈액학적 철분 영양상태 평가 지표의 비교 분석 및 판정 (III))

  • 유경희
    • Journal of Nutrition and Health
    • /
    • v.33 no.5
    • /
    • pp.532-539
    • /
    • 2000
  • The purpose of this research is to assess th iron nutritional status of pregnant women and to evaluate the appropriateness of the present cut off levels of hemoglobin(Hgb), hematocrit(Hct) and total iron binding capacity(TIBC) for assessing iron deficiency status. Pregnant women who were visiting public helath centers in Ulsan were interviewed and agreed to attend the study. Blood sample was taken and biochemical analysis of blood was performed. The collected data were classified into 3 trimesters by gestational age and then statistical analysis was performed. The prevalence of anemia in all subjects was 32.3% by WHO criteria(Hgb < 11.0g/dl) and 17.8% of all subjects was iron deficient anemia by CDC criteria(Hgb < 11.0/dl and serum ferritin < 12.0ug/l). Since the iron deficient anemia generally occures at the last stage of iron deficiency, it is not efficient to diagnose and prevent the iron deficient anemia in pregnant women by using the present cut off level of Hgb. Therefore, the new cut off level of iron status indices is necessary for assessing iron deficiency in early pregnancy before manifestation of anemia and for reducing the prevalence of anemia in later pregnancy. For this reason, the present cut off levels of iron status indices were estimated and compared by assessing the iron deficiency judged by serum ferritin level (<12.0ug/l)as true iron deficiency. It follows from the results of this research that present cut off levels of Hgb, Hct and TIBC were very insensitive in identifying the subjection with iron deficiency. The appropriate cut off levels of Hgb were 11.5g/dl for total period of pregnancy, 12.0g/dl for 1st and 3rd trimester, and 11.5g/dl for 2nd trimester. The cut off level of Hct was 34.0% for total period for pregnancy, 35.0% for 1st trimester, and 34.0% for 2nd and 3rd trimester. The cut off level of TIBC was 400ug/dl for total period, 360ug/dl for 1st 2nd trimester, and 450ug/dl for 3rd trimester.

  • PDF

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Association between False Positive, False Negative, High-Background Cases and Humidity in One Lambda LABTypeTM HLA-DR Typing (One Lambda LABTypeTM을 이용한 HLA- DR Typing시 나타나는 위양성과 위음성, High-Background 사례와 검사실 습도의 관계분석)

  • Hyang Son AN;Minsung SOHN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.132-142
    • /
    • 2023
  • Human leukocyte antigen (HLA) typing was performed in the diagnostic immunology laboratory of the Seoul National University Hospital. Among 611 HLA-DR tests, specific bead reactions suspected of being false positive and false negative in Lot 20 reagents were found. Therefore, we aimed to identify the factors causing cut-off corrections by examining cases where cut-off corrections were not made for 533 test results and cases where cut-off corrections were made for 78 cases after the cut-off corrections of specific beads. Frequency analysis was conducted to verify the demographic characteristics, and descriptive statistics were used to assess the humidity in the laboratory as a variable. Cross-tabulation was done to examine the association between cut-off corrections and demographic characteristics. Independent samples t-tests were conducted to verify the difference in humidity based on cut-off corrections. Finally, logistic regression analysis was conducted to examine the relationship between humidity levels and the rate of cut-off corrections, and results showed as the humidity level in the laboratory highs, the number of cut-off corrections decreased by a factor of 0.986. This suggests cut-off corrections rate increases when the humidity lowers. Therefore, it indicates that humidity in the laboratory is also a factor that affects HLA typing results.

Determination of Urinary Cotinine Cut-Off Point for Discriminating Smokers and Non-Smokers among Adolescents: The Third Cycle of the Korean National Environmental Health Survey (2015~2017) (청소년의 흡연자 선별을 위한 소변 중 코티닌 절사점 결정: 제3기 국민환경보건 기초조사(2015~2017))

  • Jung, Sunkyoung;Park, Sangshin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.320-329
    • /
    • 2021
  • Background: Smoking exposure may be objectively assessed through specific biomarkers. The most common biomarker for smoking is cotinine concentration in urine, and setting an optimal cut-off point can accurately classify smoking status. Such a cut-off point for Korean adolescents has never been studied. Objectives: The aim of this study was to determine a cut-off point for urinary cotinine concentration for the discrimination of smoking in adolescents. Methods: Participants were adolescents aged 13~18 years who participated in the third cycle of the Korean National Environmental Health Survey. We used urine samples to confirm the level of cotinine concentrations. Smoking status was determined by self-reported questionnaire. We identified the optimal cotinine cut-off point for discriminating smoking status using receiver operating characteristic curve analysis. Results: Of the 904 participants, 28 (3.1%) were smokers, among whom 20 (71.4%) were male. The median urinary cotinine concentrations in smokers was 218 ㎍/L (male: 215 ㎍/L, female: 303 ㎍/L), and that in non-smokers was 1.31 ㎍/L (male: 1.46 ㎍/L, female: 1.18 ㎍/L). We found significant differences in urinary cotinine concentration according to smoking status and sex (p<0.001). Urinary cotinine concentrations performed well for identifying smoking adolescents [area under the curve: 0.954 (male: 0.963, female: 0.908)]. The cut-off that optimally distinguished smokers from non-smokers was 39.85 ㎍/L (sensitivity: 89.3%, specificity: 97.4%). Male [39.85 ㎍/L (sensitivity: 90.0%, specificity: 94.9%)] had a different optimal cut-off point than female [26.26 ㎍/L (sensitivity: 87.5%, specificity: 99.6%)]. Conclusions: This study determined a cut-off point for urinary cotinine of 39.85 ㎍/L (male: 39.85 ㎍/L, female: 26.26 ㎍/L) to distinguish smokers from non-smokers in adolescents.

Comparative Evaluation of the Risk of Malignancy Index Scoring Systems (1-4) Used in Differential Diagnosis of Adnexal Masses

  • Ozbay, Pelin Ozun;Ekinci, Tekin;Caltekin, Melike Demir;Yilmaz, Hasan Taylan;Temur, Muzaffer;Yilmaz, Ozgur;Uysal, Selda;Demirel, Emine;Kelekci, Sefa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.345-349
    • /
    • 2015
  • Background: To determine the cut-off values of the preoperative risk of malignancy index (RMI) used in differentiating benign or malignant adnexal masses and to determine their significance in differential diagnosis by comparison of different systems. Materials and Methods: 191 operated women were assessed retrospectively. RMI of 1, 2, 3 and 4; cut-off values for an effective benign or malignant differentiation together with sensitivity, specificity, negative and positive predictive values were calculated. Results: Cut-off value for RMI 1 was found to be 250; there was significant (p<0.001) compatibility at this level with sensitivity of 60%, positive predictive value (PPV) of 75%, specificity of 93%, negative predictive value (NPV) of 88% and an overall compliance rate of 85%. When RMI 2 and 3 was obtained with a cut-off value of 200, there was significant (p<0.001) compatibility at this level for RMI 2 with sensitivity of 67%, PPV of 67%, specificity of 89%, NPV of 89%, histopathologic correlation of 84% while RMI 3 had significant (p<0.001) compatibility at the same level with sensitivity of 63%, PPV of 69%, specificity of 91%, NPV of 88% and a histopathologic correlation of 84%. Significant (p<0.001) compatibility for RMI 4 with a sensitivity of 67%, PPV of 73%, specificity of 92%, NPV of 89% and a histopathologic correlation of 86% was obtained at the cut-off level 400. Conclusions: RMI have a significant predictability in differentiating benign and malignant adnexal masses, thus can effectively be used in clinical practice.

The Optimal Cut Off Score According to Self-Rated Health in Early Adulthood (초기 성인기 주관적 건강상태에 따른 절단 값 제시)

  • Kim, Yun-Young;Jang, Eun-Su
    • The Korean Journal of Health Service Management
    • /
    • v.11 no.2
    • /
    • pp.105-115
    • /
    • 2017
  • Objectives : The aim of this study was to suggest the optimal cut off for best, very good, good, slightly bad, and bad grades. Methods : The subjects were recruited from 4 areas of South Korea and 487 questionnaires were analyzed. The nominal and continuous self-rated health questions were used to reveal the optimal cut off and the Short Form-12 Health Survey questionnaire (SF-12) was additionally used. Frequency, Pearson's correlation coefficient, and ROC-curve analysis were used; the significance level was <.05. Results : Subjects assigned 15(3.1%), 90(18.5%), 237(48.7%), 130(26.7%), and 15(3.1%) to best, very good, good, slightly bad and bad groups respectively. The self-rated health score was associated with total Component (r=.563, p<.001), Physical Component (r=.520, p<.001) and Mental Component of SF-12 (r=.303, p<.001). The optimal cut off was 80.5, 70.5, 53.5, and 40.5 for best, very good or more, good or more, and under slightly bad respectively and area under curve was 0.898, 0.908, 0.945, and 0.908 accordingly. Conclusions : This study suggests that the self-rated health score and grade could be integrated with the optimal cut off.

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF