• 제목/요약/키워드: cusp height

검색결과 46건 처리시간 0.024초

상악구치 교합면의 design 조각법에 관한 연구 (A Study on the design waxup technique for maxillary molar occlusion)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.97-114
    • /
    • 1999
  • The first function of occlusion is mastication. Therefore the functional restoration of occlusal surface is very important. The restoration of occlusal surface is three method as wax bite technique, F.G.P. technique, cone technique. Many dental technician is using compound method. I have knew common point on each teeth during I have waxing up wax pattern. So I studied on the design waxup technique for maxillary molar occlusion. The results of the study were as follows ; 1. The dam wax up method can restore axial contour of teeth very easy and make short working time of wax pattern. 2. The height of dam must be same with cusp of adjacent teeth. 3. Automatically the contour of tooth is appeared if the contour of dam is relationship with cuspid line of adjacent teeth. 4. The height of contour of buccal, lingual surface is formed natural curve to add fluid wax by gravitation. 5. The development groove of Maxillary premolar is appeared V form. 6. The development groove of Maxillary molar is appeared W form. 7. The embrasure is formed to carve around contact point area as round convex. It affects to axial form of tooth. 8. I was knew that the lingual groove and stuart's groove of molar runs parallel with oblique ridge. 9. The buccal groove of molar is formed parallel with direction of teeth arrangement.

  • PDF

정상인의 교합 만곡 분석에 관한 연구 (A STUDY ON THE ANALYSIS OF OCCLUSAL CURVE OF THE NORMAL SUBJECTS)

  • 최명식;계기성;강동완
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.95-122
    • /
    • 1990
  • This study was done to analyze the occlusal curve as one of the factors to be considered for maintenance of occlusal stability in the orthodontic and prosthodontic treatments. Sixty gnathological casts we.e obtained from 43 subjects with normal occlusion and 17 subjects with some of temporomandibular disorders. The occlusal surfaces of gnathologic casts were duplicated by using a Color kit SK-700 and tile reference points of X, Y coordinates were digitized by using the Summagraphic digitizer and 18AT computer system. The Z coordinates of cusp height were measured by 0.01mm measurable caliper. The mathematical computer program of least square method was used to analyze the occlusal curve arranged by three dimensional coordinates of X, Y, Z. The following results were obtained : 1. The occlusal curve of buccal and lingual cusp tips was fitted to the ellipse, and the occlusal curve of anterior teeth was fitted to a part of the circle in the analysis of conic sections. 2. The radius of Spee's curve showed individual differences, but was average 98.7mm in male subjects and 93.7mm in female subjects. 3. The radius fo Spee's curve according to the half of canine width showed the least coefficient of variation. 4. The radius of Spee's curve was not significantly relative to the lateral occlusal contacts on laterotrusion and the absence or presence of temporomandibular disorders. 5. The radius of Wilson's curve showed individual difference and the size of radius was followed by the order of 1st premolar, 2nd premolar, 2nd molar and 1st molar.

  • PDF

한국 성인 심장의 승모판 복합체에 관한 형태학적 연구 (The Morphologic Study of the Mitral Valve Complex in Korean Adult Hearts)

  • 오중환;이규석;박형우
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1128-1138
    • /
    • 1990
  • The mitral valve is not a simple but a complex structure, mitral valve complex. This complex is composed of mitral orifice, annulus, valve leaflet, chordae tendineae and papillary muscles. There were many controversies about this structures. We studied mitral valve complex in 63 cases of normal Korean adults, such as the circumference of mitral annulus, the intercommissural diameter, height and breadth of the cusps, including commissure, the ratio of rough to clear zone, breadth of the achordal zone, the number of scallops of posterior cusp, the number, length and the pattern of arrangement of the several types of chordae, the number and morphological characteristics of papillary muscles.

  • PDF

곡면 경계부 미절삭 체적의 잔삭 가공에 관한 연구 (A Study on Machining of Uncut Volume at the Boundary Region of Curved Surfaces)

  • 맹희영;임충혁
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.251-259
    • /
    • 2010
  • It is presented in this study a new efficient intelligent machining strategy, which can be used to remove the uncut volume at the boundary region of curved surfaces caused by cutter interference. The geometric form definitions and recognition of topological features of the surface triangulation mesh are used to generate cutter paths along successive and interconnected steepest pathways, that minimize the cusp height left after flat end milling. In order to machine the uncut volume gradually, the z-map cutter centers are adjusted to avoid cutter interference for the 6 kinds of avoidance types. And then, the generative subsequent paths are sequenced to determine the second step cutter paths for the next uncut volume. For the 2 kinds of test models with convex and concave surface region, the implemented software algorithm is evaluated by investigating the residual swelling of uncut volume for each machining step.

3D 프린팅 시간 단축을 위한 상하 레이어 폴리라인 병합 기반 가변 슬라이싱 (Adaptive Slicing by Merging Vertical Layer Polylines for Reducing 3D Printing Time)

  • 박지영;강주형;이혜인;신화선
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제22권5호
    • /
    • pp.17-26
    • /
    • 2016
  • 본 논문에서는 상하 레이어 폴리라인 병합(merging) 기반 가변(adaptive) 슬라이싱 기법을 제안한다. 먼저 출력 가능한 최소 두께 값을 사용하여 입력된 3D 폴리곤 모델을 균일(uniform) 슬라이싱하고 각 레이어 단면 영역의 경계에 대한 폴리라인(polyline)들을 생성한다. 다음으로 상하 연결성이 높은 폴리라인들을 그룹화한 후, 각 그룹 내에서 불필요한 폴리라인들을 삭제한다. 삭제할 레이어를 결정하기 위해 기하오차척도인 커스프 높이(cusp height)를 계산하고 이를 기반으로 적정 레이어 두께를 결정한다. 마지막으로레이어 두께 범위 내의 폴리라인들을 삭제함으로써 한 개 레이어로 병합된다. 제안 방법은 형상의 특징을 최대한 유지함과 동시에 출력 시간을 효과적으로 단축시킨다는 장점을 가진다. 성능 검증을위해 제안 기법과 전역적 가변 슬라이싱 기법을 사용하여 총 10개 3D 폴리곤 모델을 슬라이싱 한 후 출력 시간을 결정짓는 수치인 폴리라인의 총 길이를 측정하였다. 실험 결과, 모든 모델에 대해 제안한 기법의 폴리라인 총 길이가 더 짧았으며 이는 더 빠른 시간에 출력을 완료할 수 있다는 것을 의미한다.

단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE)

  • 황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE)

  • 김수관;김재덕;김종관;김병옥
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구 (Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth)

  • 최유성;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.129-146
    • /
    • 2008
  • 본 연구에서는 다양한 치과 수복재료에 대합되는 의치용 레진치의 마모저항성을 알아보기 위해 통상의 아크릴 릭 레진치인 $Trubyte^{(R)}$ $Biotone^{(R)}$ (Dentsply, U.S.A.)과 고강도 레진치인 Endura $Posterio^{(R)}$ (Shofu, Japan), Physio $Duracross^{(R)}$ (Nissin, Japan)를 수복재료인 금합금, 도재, 충전용 레진에 대합시켜 마모저항성을 비교 분석하였다. 또한 앞의 세 종류의 레진 인공치와 5종류의 의치세정제인 유한락스, 폴리덴트, 싸이덱스, 헥사메딘, 증류수를 사용하여 의치세정제 및 소독제가 경도에 미치는 영향을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 대합되는 수복재료로 충전용 레진, 도재를 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이감소가 컸으며 세 재료간의 유의한 차이를 보였다 (p<0.05). 2. 대합되는 수복재료로 금합금을 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이 감소가 컸으며, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$ 이 다른 두 종류의 인공치보다 유의성 있게 높은 교두정 높이 감소를 보였다 (p<0.05). 3. 대합되는 수복재료로 충전용 레진, 금합금, 도재를 사용한 경우 모두 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 무게 감소가 컸으며, 세 재료간의 유의한 차이를 보였다 (p<0.05). 4. 의치세정제에 따른 경도 감소는 실험 전과 후의 측정치를 비교했을 때 모든 레진 인공치에서 유의성 있는 차이 를 나타내었다 (p<0.05). 5. 유한락스, 싸이덱스, 헥사메딘에 담구었던 레진 인공치에 의한 경도감소는 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 높은 감소를 보였고, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$이 다른 두 종류의 인공치보다 유의성 있게 높은 경도 감소를 보였다 (p<0.05). 이상의 실험 결과 마모저항성 실험에서는 최근에 개발된 Physio $Duracross^{(R)}$가 다른 두 종류의 레진 인공치에 비해 세 종류의 대합되는 수복재료 모두에서 높은 마모저항성을 보였고 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 높은 마모저항성을 보였다. 경도 실험에서는 Physio $Duracross^{(R)}$와 Endura $Posterio^{(R)}$$Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 낮은 경도감소를 보였고 (p<0.05), 폴리덴트, 증류수에서는 유의한 차이를 보이지 않았다. 따라서, Physio $Duracross^{(R)}$가 세 종류의 레진 인공치에 비해 우수한 마모저항성을 보인다고 볼 수 있고, Endura $Posterio^{(R)}$와 함께 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해서 우수한 경도를 보인다고 볼 수 있지만, 단편적인 실험 결과이므로, 아직은 신중하게 고려되어야 하고, 더 많은 연구가 필요하다고 사료된다.

미각 회복을 위한 무구개 의치(Palateless Complete Denture)의 임상증례 (PALATELESS COMPLETE DENTURE FOR RESTORING GOOD TASTES : A CASE REPORT)

  • 송언희;김래경;안현정;변숙;최병갑
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.819-824
    • /
    • 1999
  • The purpose of this article is to present a clinical case report for palateless complete denture. Despite the contravacy of palatal uncoverage in upper complete denture, palateless complete denture has some merits for upper edentulous patient. Following the uncovering of the palatal portion, the patient became easy to talk and restored the lost good tastes. He is happy despite of the decrease of the retention of the upper complete denture. Palateless complete denture is a compatible alternative fir upper edentulous patients in cases of gagging, large palatal torus and restoring the lost good tastes. The clinical points are as follows : 1. The remaning alveolar ridge should be ovoid and have enough width and height for the sup-port and retention. 2. The patient must have strong wish to the palateless complete denture. 3. Palatal beading made on the palatal peripheral border give good border sealing of the palatal flange and minimaized the prominence of the denture flange 4. The peripheral border of the palatal flange should be reduced as thin as possible for more comfort. 5. Upper artificial posterior teeth should be arranged over the alveolar ridge crest and inner incline of the buccal cusp relieved for denture stability while chewing. 6. For stability of palateless complete denture, bilateral balanced occlusion should be sttained. Palateless complete denture will restore the lost good tastes and more comfortable and physiologic to upper edentulous patients and a good alternative to full palatal coverage complete denture in the properly selected cases.

  • PDF

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • 장두희;박민;김선호;정승호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF