• Title/Summary/Keyword: current-fed

Search Result 793, Processing Time 0.026 seconds

Bi-directional DC-DC Converter Design and Control for step-up/step-down (승강압용 양방향 DC-DC컨버터 설계 및 제어)

  • Won, Chung-Yuen;Jang, Su-Jin;Lee, Tae-Won;Lee, Byoung-Kuk;Kim, Soo-Suck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.49-56
    • /
    • 2006
  • The bi-directional converter interfaces the low voltage battery to the inverter do link of FC generation system. When power flows from the low voltage side(battery: 48[V]) to the high voltage side(dc link: 380[V]), the circuit works in discharge mode (boost) to power the high voltage side load; otherwise, it works in charge mode (buck) to charge the low voltage side battery. In this paper, the 1.5[kW] active clamp current-fed full bridge converter employing MOSFETs is operated to discharge the battery whereas a voltage-fed half bridge converter employing IGBTs is operated to charge the battery.

A New Non-isolated Boost Converter with Two-Inductor and One-Transformer for Hybrid Electric Vehicle and Electric Vehicle (하이브리드 차량 및 전기 차량용 두 개의 인덕터와 하나의 변압기를 갖는 새로운 비절연형 부스트 컨버터)

  • Sung, Hyun-Wook;Park, Ki-Bum;Kim, Tae-Sung;Moon, Gun-Woo;Youn, Myung-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.132-134
    • /
    • 2007
  • 하이브리드 차량 및 전기차량 구동 모터의 권선저항에 의한 손실 및 모터의 크기를 줄이기 위해 고효율, 고승압형 DC-DC 컨버터 사용이 요구된다. 기존의 부스트 컨버터는 기생저항 성분에 의해 고승압이 불가능하여 변압기를 사용하여 승압비를 향상시킨 current-fed push-pull, current-fed full bridge, dual inductor-fed 부스트 컨버터 등으로 변형되어 사용되어 왔다. dual inductor-fed 부스트 컨버터의 경우 동일조건하에서 앞서 기술된 2가지 컨버터보다 2배의 승압비를 얻을 수 있으며 1차측 전류 스트레스가 낮은 장점을 가지고 있어 대전력, 고승압 응용에 적합하다. 하지만 변압기의 누설인덕턴스에 의한 써지성 전류/전압을 제한하기 위한 부가적인 snubber회로의 사용으로 효율을 떨어뜨리게 되는 단점을 가지고 있다. 본 논문에서는 이러한 단점을 보완할 수 있는 새로운 2개의 인덕터와 1개의 변압기를 갖는 DC-DC 컨버터를 제안한다. 제안된 컨버터의 동작원리와 모드해석을 실시하고 최종적으로 400W, 42Vdc (Battery)/400Vdc (Electric Motor) 실험결과를 통해 이를 검증한다.

  • PDF

Grid-tied Power Conditioning System for Fuel Cell Composed of Three-phase Current-fed DC-DC Converter and PWM Inverter

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.255-262
    • /
    • 2011
  • This paper proposes a grid-tied power conditioning system for fuel cell, which consists of three-phase current-fed DC-DC converter and three-phase PWM inverter. The three-phase current-fed DC-DC converter boosts fuel cell voltage of 26-48 V up to 400 V with zero-voltage switching (ZVS) scheme, while the three-phase PWM(Pulse Width Modulation) inverter controls the active and reactive power supplied to the grid. The operation of the proposed power conditioning system with fuel cell model is verified through simulations with PSCAD/EMTDC software. The feasibility of hardware implementation is verified through experimental works with a laboratory prototype with 1.2 kW proton exchange membrane (PEM) fuel cell stack. The proposed power conditioning system can be commercialized to interconnect the fuel cell with the power grid.

Modeling and Analysis of Leakage Currents in PWM-VSI-Fed PMSM Drives for Air-Conditioners with High Accuracy and within a Wide Frequency Range

  • Sun, Kai;Lu, Yangjun;Xing, Yan;Huang, Lipei
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.970-981
    • /
    • 2016
  • Leakage currents occur in pulse-width-modulated voltage source inverter (PWM-VSI)-fed permanent magnet synchronous motor (PMSM) drives for air-conditioners, which seriously affect system safety and operation performance. High accuracy modeling and prediction of leakage currents are key issues for the design and implementation of air-conditioning products. In this study, the generation mechanism of leakage currents is discussed. A systematic modeling approach of leakage currents is proposed, including the modeling of leakage current sources and leakage current paths. By using the proposed approach, the complete model of leakage currents in PWM-VSI-fed PMSM drives for air-conditioners has been developed based on the extraction of all parameters. A comparison between the simulated leakage currents based on the developed model and measured leakage currents in the outdoor unit of an air-conditioning product is conducted. The comparison verifies the effectiveness of the proposed modeling approach, and the developed model exhibits high accuracy within a wide frequency range.

Control Design of the Brushless Doubly-Fed Machines for Stand-Alone VSCF Ship Shaft Generator Systems

  • Liu, Yi;Ai, Wu;Chen, Bing;Chen, Ke
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.259-267
    • /
    • 2016
  • This paper presents a stand-alone variable speed constant frequency (VSCF) ship shaft generator system based on a brushless doubly-fed machine (BDFM). In this system, the output voltage amplitude and frequency of the BDFM are kept constant under a variable rotor speed and load by utilizing a well-designed current vector controller to regulate the control winding (CW) current. The control scheme is proposed, and the hardware design for the control system is developed. The proposed generator system is tested on a 325 TEU container vessel, and the test results show the good dynamic performance of the CW current vector controller and the whole control system. A harmonic analysis of the output voltage and a fuel consumption analysis of the generator system are also implemented. Finally, the total efficiency of the generator system is presented under different rotor speeds and load conditions.

A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel(PDP)

  • Han, Sang-Kyoo;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020${\times}$l06mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.

A simple energy recovery circuit with current-fed type for plasma display panel (PDP) (간단한 전류원 형태의 구조를 갖는 새로운 PDP 에너지 회수 회로)

  • Yi, Kang-Hyun;Han, Sang-Kyoo;Choi, Seong-Wook;Kim, Chong-Eun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.376-379
    • /
    • 2005
  • High efficiency and low cost sustain driver for plasma display panel (PDP) with current fed is proposed. Main concept of the proposed circuit is using the current source to charge and discharge panel. As a result, all power switches can achieve the zero voltage switching (ZVS) and every auxiliary switch can also do the zero current switching (ZCS). Moreover, since the inductor current can compensate the discharge current, the current stress of all power switches can be reduced considerably. Furthermore, it has features as a simpler structure, less mass, less cost, and lower electromagnetic interference than prior circuit.

  • PDF

Control Method of a Doubly-fed Induction Generator with Grid Synchronization unaffected by encoder position (엔코더 위치에 강인한 계통연계 기능을 갖는 권선형유도발전기 제어 기법)

  • Park, Jung-Woo;Lee, Ki-Wook;Kim, Dong-Wook;Lee, Kwang-Soo;Park, Jin-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.125-129
    • /
    • 2006
  • In order to transmit energy generated through the stator winding of a doubly-fed Induct ion generator (DFIG), we need to synchronize the generated voltage vector with the grid voltage vector. However, the existing synchronization method works only when the encoder is installed at a specific Position and equivalent constant is precise. In order to solve this Problem, a new synchronization method has been proposed and a way of applying the method to existing doubly-fed induction generator control algorithm has been also proposed. The validity of the proposed methods have been verified using a prototype converter for the control of a 1.5MW-class doubly-fed induction generator

  • PDF

Study on Vacuum Packaging of Field Emission Display (Field Emission Display의 고진공 실장에 관한 연구)

  • Lee, Duck-Jung;Ju, Byeong-Kwon;Jang, Jin;Oh, Myong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.103-106
    • /
    • 1999
  • In this paper, we suggest the FED packaging technology that have 4mm thickness, using sodalime glass-to-sodalime glass electrostatic bonding. It based on conventional silicon-glass bonding. The silicon film was deposited an around the exhausting hole on FED backside panel. And then, the silicon film of panel was successfully bonded with capping(bare) glass in vacuum environment and the FED panel was vacuum-sealed. In this method, we could achieve more 153 times increased conductance and 200 times increased vacuum efficiency than conventional tube packaging method. The vacuum level in panel, by SRG test, was maintained about low 10$_{-4}$ Torr during above two months And, the light emission was observed to 0.7-inch tubeless packaged FED. Then anode current was 34 $\mu$ A. Emission stability was constantly measured for 10 days.

  • PDF