• 제목/요약/키워드: current-fed

검색결과 793건 처리시간 0.024초

인터리브드된 전류 주입형 고승압 DC-DC 컨버터 (Interleaved Current-fed High Step-up DC-DC Converter)

  • 이준호
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.586-591
    • /
    • 2020
  • 본 논문에서는 인터리브된 전류 주입형 고승압 DC-DC 컨버터가 제안된다. 높은 전압 이득 외에도 인터리빙 방식을 채택하여 낮은 리플 입력 전류가 달성된다. 또한 제안 된 컨버터의 소프트 스위칭 특성은 전력 스위치의 스위칭 손실을 줄이고 변환 효율을 높인다. 변압기의 누설 인덕턴스를 활용하여 다이오드의 전류 변화율을 제어함으로써 출력 정류기의 역 회복 문제도 완화된다. 200W 프로토 타입에서 얻은 실험 결과에 대해 설명한다.

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.

A Comparative Study of Controllers for CSI Fed Induction Motor

  • Kumar, Piush;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.165-170
    • /
    • 2010
  • This paper presents a comparative study of P and PI controllers for a current source inverter (CSI) fed induction motor drive system. A dq model has been used which incorporates the induction motor and the inverter power supply with current feedback. The model is used first to generate the steady state curves to determine the operating point through computer simulations using the software package MATLAB. Then a transient analysis has been carried out for different values of the speed and current controller parameters. The controller value is adjusted by the Ziegler-Nichols method. It has been observed that the transient time to reach the steady state value is larger with the PI controller than with the P controller.

An Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame

  • Phan, Van-Tung;Lee, Hong-Hee;Chu, Tae-Won
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.724-732
    • /
    • 2010
  • This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposing the positive and negative sequence components of the measured rotor current. In addition, the behavior of the proposed controller is examined in terms of control performance and stability with respect to rotor speed variations, i.e., slip frequency variations. Simulations and experimental results are shown to validate the robustness and effectiveness of the proposed control method.

회전자 여자제어를 이용한 권선형 유도발전기의 최대출력 (Maximum Output Power using the Doubly Fed Induction Generator)

  • 이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.6-8
    • /
    • 1998
  • This paper deals with the maximum output power generation using the Dounly Fed Induction Generator(DFIG) in the super-synchronous speed regions, by control of both magnitude and phase of the voltage fed to the rotor. Steady-state algebraic equations of the euivalent circuit are solved using numerical analysis. For the normal operating region, in which the generator ratings are not exceeded, rotor current is less than or equal to the rated value. By selecting the permisible rated current at rotor coil, there are the optimal solution existng which covers the magnitude and phase of the injected voltage to the rotor for the given slip. This optimal solution is pointing out how the maximum output power can be carried out.

  • PDF

An Improved Control Strategy Using a PI-Resonant Controller for an Unbalanced Stand-Alone Doubly-Fed Induction Generator

  • Phan, Van-Tung;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.194-202
    • /
    • 2010
  • The main cause of degradation in an unbalanced stand-alone doubly-fed induction generator (DFIG) system is negative sequence components that exist in the generated stator voltages. To eliminate these components, a hybrid current controller composed of a proportional-integral controller and a resonant regulator is developed in this paper. The proposed controller is applied to the rotor-side converter of a DFIG system for the purpose of compensating the negative stator voltage sequences. The proposed current controller is implemented in a single positive rotating reference frame and therefore the controller can directly regulate both the positive and negative sequence components without the need for sequential decomposition of the measured rotor currents. In terms of compensation capability and accuracy, simulations and experimental results demonstrated the excellent performance of the proposed control method when compared to conventional vector control schemes.

Reduction of Current Ripples due to Current Measurement Errors in a Doubly Fed Induction Generator

  • Park, Gwi-Geun;Hwang, Seon-Hwan;Kim, Jang-Mok;Lee, Kyo-Beum;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.313-319
    • /
    • 2010
  • This paper proposes a new compensation algorithm for the current measurement errors in a DFIG (Doubly Fed Induction Generator). Generally, current measurement path with current sensors and analog devices has non-ideal factors like offset and scaling errors. As a result, the dq-axis currents of the synchronous reference frame have one and two times ripple components of the slip frequency. In this paper, the main concept of the proposed algorithm is implemented by integrating the 3-phase rotor currents into the stationary reference frame to compensate for the measured current ripples in a DFIG. The proposed algorithm has several beneficial features: easy implementation, less computation time, and robustness with regard to variations in the electrical parameters. The effectiveness of the proposed algorithm is verified by several experiments.

공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템 (Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side)

  • 유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

The Design of Long-Stator Linear Motor Drives for RailCab Test Track

  • Grotstollen Horst
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.166-172
    • /
    • 2005
  • The basic equations of a doubly-fed long-stator linear motor for a shuttle-based railway system are established. They show which degrees of freedom exist for controlling the motor. The ratio of stator and rotor current proves to be an important parameter in determining the design of motors, converters and mechanics.

인버터 부착형 농형 유도발전기의 계통고장특성 모의 (Grid faults characteristics simulation of inverter-fed induction generator)

  • 홍지태;권순만;김춘경;이종무;천종민;김홍주;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF