• 제목/요약/키워드: current waveform

검색결과 724건 처리시간 0.032초

Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.213-217
    • /
    • 2008
  • The flux-lock type superconducting fault current limiter(SFCL) can apply the magnetic field into the high-$T_C$ superconducting(HTSC) element by adopting the magnetic field coil in its third winding. To apply the magnetic field into the HTSC element effectively, the capacitor for LC resonance is connected in series with the magnetic field coil. However, the current waveform of third winding for the application of the magnetic field is affected by the LC resonance condition for the frequency of the source voltage and can affect the waveform of the limited fault current. In this paper, the current waveform of the third winding in the flux-lock type SFCL according to LC resonance condition during a fault period was analyzed. From the differential equation for its electrical circuit, the current equation of the third winding was derived and described with the natural frequency and the damping ratio as design parameters. Through the analysis according to the design parameters of the third winding, the waveform of the limited fault current was confirmed to be influenced by the current waveform of the third winding and the design condition for the stable fault current limiting operation of this SFCL was obtained.

실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구 (A Study on Welding Process Algorithm through Real-time Current Waveform Analysis)

  • 윤진영;이영민;신순철;최해운
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.

High-efficiency Operation of Switched Reluctance Generator based on Current Waveform Control

  • Li, Zhenguo;Yu, Siyang;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.120-126
    • /
    • 2013
  • The main aim of this paper is to expound high-efficiency operation of Switched Reluctance Generator (SRG) based on the current waveform. For this purpose, theoretical analysis of the copper loss and iron loss of the system is done first. Then, necessary simulation is done to find the variation trend of the copper loss and iron loss with the variation of the current waveform at the same output power. Finally, the best current waveform which can make the system operate with high efficiency is obtained by considering the influence of these two kinds of loss. In order to verity the simulation results, the experimental platform of DC motor-SRG is built and the modified angle position control (APC) method which can specify the current shape optionally is presented. By comparing the system efficiency at the three kinds of typical current waveform, the correctness and feasibility of the theory is verified. The proposed method is simple, reliable, and easy to achieve.

전류 파형 제어를 적용한 마그네슘 합금의 저항 점 용접 특성 (Resistance Spot Welding Characteristics of Mg Alloy Applying Current Waveform Control)

  • 최동순;황인성;김동철;류재욱;강문진
    • Journal of Welding and Joining
    • /
    • 제32권2호
    • /
    • pp.70-75
    • /
    • 2014
  • In automotive industry, applying of Mg alloy to autobody has been issued recently as a light metal. But poor resistance spot weldability of Mg alloy is blocking commercialization. So studies on improving resistance spot weldability of Mg alloy is increasing continuously. For reduce loss of heat input during welding, inverter DC power source is considered because of short rise time to target welding current. But rapid rising of welding current can increase temperature rapidly in nugget and oxide film between electrode and base metal, and that causes generating expulsion on low welding current range. In this study, for increase optimum welding current range and prevent generating expulsion, applicate various types of welding current waveform controls during resistance spot welding. For analysis effects of each current waveform control, acceptable welding current regions according to electrode force and welding time is determined and lobe diagram is derived. In result, pre heat is proposed as optimum type of welding current waveform control.

3상 AC/DC 스위치 모드 승압형 컨버터를 이용한 CO2 아크 용접기 역률개선에 관한 연구 (A Study on Power Factor Correction of CO2 Arc Welder Using Three Phase Switch Mode Converter)

  • 이정훈;김재문;안정준;이상석;원충연;김세찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.149-153
    • /
    • 1998
  • In this paper A switched mode AC/DC three phase boost converter with high power factor and sinusoidal input current waveform is analyzed and simulated. The proposed converter retain high power factor and sinusoidal input current waveform even under electric arc welder load. It is shown that experimental result and simulation waveform yield a sinusoidal input current waveform at high power factor.

  • PDF

도전성 분말에 의한 아크전류의 파형 및 실효값 특성 (Characteristics on Arc Waveform and RMS of Current by Conductive Powder)

  • 김두현;강양현
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

박판의 고속용접을 위한 펄스MAG 용접전원의 파형제어에 관한 연구 (Current waveform Control of Pulse MAG Welding Power Source for High Speed Welding of Thin Plates)

  • 구헌회;김태진;김준홍;이현우;조상명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.571-578
    • /
    • 1999
  • Current waveform control of pulse MAG welding power source is studied so that welding of thin plates may obtain high speed and improved performance. In this paper, waveform control method is proposed, digital controller using DSP is able to control the current waveform precisely. High speed welding of thin plates using pulse MAG welding method is made possible. Performance test for 1.2mm thin plates is carried out, output waveform and welding performance is analyzed.

  • PDF

고전류 $CO_2$용접에서의 금속이행 및 스패터 발생 현상에 관한 연구 (A Study on the Metal Transfer and Spatter Generation in High Current $CO_2$ Welding)

  • 김남훈;유회수;김희진;고진현
    • Journal of Welding and Joining
    • /
    • 제21권3호
    • /
    • pp.51-57
    • /
    • 2003
  • The metal transfer in $CO_2$ welding shows the transition of transfer mode from short-circuiting to repelled transfer will the increase of welding current. While the short-circuiting mode in $CO_2$ welding has been studied very extensively relating with droplet formation and spatter generation, the repelled transfer has little been understood. In this study, high current $CO_2$ welding has been performed with bead-on-plate welds along with the waveform analyzer and high speed camera. The image of high speed camera was synchronized with its waveform so that the moment of spatter generation could be realized during drop detachment. As a results of this study, it was found that welding arc changes its location either once or three times and thus single or double pulse signals were developed in the voltage waveform. Whenever the arc moved its location, new arc was developed in a explosive way and thus it caused spatter generation. Specially severe spattering took place when the waveform showed a double-peak pattern. As a consequence of these results, new waveform control techniques could be suggested for suppressing the spatter generation in the high-current $CO_2$ welding.

사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석 (Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings)

  • 유재근;이상익;전정채;정종욱;임용배
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.155-161
    • /
    • 2005
  • 사무용 빌딩의 비선형 전자부하에 기인한 전압 및 전류파형의 왜곡은 중성선의 과열, 변압기 손실, 누전차단기 오동작 등을 야기 시킨다. 본 논문에서는 사무용 빌딩에서의 전압 및 전류 고조파의 크기, 전압 및 전류 파고율(Crest Factor : CF), 전압 및 전류 불평형 등을 비교함으로써 파형왜곡 특성을 분석하였다. 분석 결과, 고조파에 의한 상 및 중성선에서의 심각한 파형 왜곡 문제와 삼상에서의 단상 부하의 부적절한 분배로 인한 전류 불평형이 심한 빌딩이 조사되었다. 본 연구 결과는 사무용 빌딩에서 합리적이고 경제적인 부하운용을 위해 사용될 수 있을 것이다.

Parameters Optimization of Impulse Generator Circuit for Generating First Short Stroke Lightning Current Waveform

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents the parameters optimization technology for generating the first short stroke lightning current waveform($10/350{\mu}s$) which is necessary for the performance tests of components of lightning protection systems, as required under IEC 62305 and the newly amended IEC 62561. The circuit using the crowbar device specified in IEC 62305 was applied to generate the lightning current waveform. To find the proper parameters of the circuit is not easy because the circuit consists of two parts; circuit I, which relates to the front of current waveform, and circuit II, which relates to the tail. A simulation in PSpise was carried out to find main factors related to the front and tail of $10/350{\mu}s$. The lightning current generator was developed by utilizing the circuit parameters found in the simulation. In the result of experiments, new parameters of the circuits need to be changed because of the difference between the simulation and the experiment results. Using the iterative method, the optimized parameters of the circuits was determined. Also a multistage-type external coil and a damping resistor were proposed to make the efficiency of generation to enhance. According to the result in this paper, an optimized first short stroke lightning current waveform was obtained.