• 제목/요약/키워드: current state analysis

검색결과 1,826건 처리시간 0.03초

Analysis and Degradation of leakage Current in submicron Device (미세소자에서 누설전류의 분석과 열화)

  • 배지철;이용재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1996
  • The drain current of the MOSFET in the off state(i.e., Id when Vgs=0V) is undesired but nevertheless important leakage current device parameter in many digital CMOS IC applications (including DRAMs, SRAMs, dynamic logic circuits, and portable systems). The standby power consumed by devices in the off state have added to the total power consumed by the IC, increasing heat dissipation problems in the chip. In this paper, hot-carrier-induced degra- dation and gate-induced-drain-leakage curr- ent under worse case in P-MOSFET\`s have been studied. First of all, the degradation of gate-induced- drain-leakage current due to electron/hole trapping and surface electric field in off state MOSFET\`s which has appeared as an additional constraint in scaling down p-MOSFET\`s. The GIDL current in p-MOSFET\`s was decreased by hot-electron stressing, because the trapped charge were decreased surface-electric-field. But the GIDL current in n-MOS77T\`s under worse case was increased.

  • PDF

Statistical analysis of CB making current in large seals industrial load using EMTDC (EMTDC를 활용한 자가용 수용가 차단기 투입전류 확률해석)

  • Yoon, Jae-Young;Choi, Heung-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.67-69
    • /
    • 2002
  • This paper presents the statistical analysis of the circuit breaker's making current in large sacle industrical loads using EMTDC. Typically, the making current includes DC components as the phase angel of making instances varies and represents as a instantaneous valus not rms. Consequently, in this paper, the statistical analysis results of making current and steady state fault current for typical industrial loads presents.

  • PDF

Thermal Analysis and Test of Eddy-Current Braker for High-Speed Train (고속전철 와전류 제동장치의 온도 특성해석 및 실험)

  • 정수진;강도현;구대현;김동희;방덕제
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제52권5호
    • /
    • pp.197-202
    • /
    • 2003
  • When a high-speed train reduces its operating velocity while decelerating from a maximum of 350 to 50 [km/h], the train applies eddy-current brakes, which results in a deceleration time of approximately 3minutes. Therefore, a high current is utilized in order to obtain a large braking force. Consequently, the temperature of the electromagnet and rail increases significantly. In this paper, The thermal characteristics on a single magnet pole with convection heat transfer coefficient are simulated by using 2D-FEM. To verify the analysis results, the computed temperatures are compared with the experimentally measured temperature at stationary state. Furthermore, transient-state thermal analysis is performed to predict the magnet temperatures as the train is decelerating.

The Impact of Gate Leakage Current on PLL in 65 nm Technology: Analysis and Optimization

  • Li, Jing;Ning, Ning;Du, Ling;Yu, Qi;Liu, Yang
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.99-106
    • /
    • 2012
  • For CMOS technology of 65 nm and beyond, the gate leakage current can not be negligible anymore. In this paper, the impact of the gate leakage current in ring voltage-controlled oscillator (VCO) on phase-locked loop (PLL) is analyzed and modeled. A voltage -to-voltage (V-to-V) circuit is proposed to reduce the voltage ripple on $V_{ctrl}$ induced by the gate leakage current. The side effects induced by the V-to-V circuit are described and optimized either. The PLL design is based on a standard 65 nm CMOS technology with a 1.8 V power supply. Simulation results show that 97 % ripple voltage is smoothed at 216 MHz output frequency. The RMS and peak-to-peak jitter are 3 ps and 14.8 ps, respectively.

Analysis Of Dielectric Recovery Characteristics for $SF_6$ Gas-Blast AFC ($SF_6$아크의 절연회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Park, Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제51권6호
    • /
    • pp.273-284
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the dielectric recovery characteristics of two types of double-flow nozzles. A commercial CFD Program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of BBC. In order to investigate the state of the arc region after current zero, the simulation was carried out with four steps. They are cold gas flow analysis, steady state arc simulation, transient arc simulation before current zero, transient hot gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl′s mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The streamer criterion was introduced to evaluate the dielectric recovery characteristics after current zero. Compared with the results obtained by assuming the current zero state in the former studies, it has been found that the results obtained by considering the state before current zerowere more accurate.

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Simplified Controller Design Method for Digitally Controlled LCL-Type PWM Converter with Multi-resonant Quasi-PR Controller and Capacitor-Current-Feedback Active Damping

  • Lyu, Yongcan;Lin, Hua
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1322-1333
    • /
    • 2014
  • To track the sinusoidal current under stationary frame and suppress the effects of low-order grid harmonics, the multi-resonant quasi-proportional plus resonant (PR) controller has been extensively used for digitally controlled LCL-type pulse-width modulation (PWM) converters with capacitor-current-feedback active damping. However, designing the controller is difficult because of its high order and large number of parameters. Moreover, the computation and PWM delays of the digitally controlled system significantly affect damping performance. In this study, the delay effect is analyzed by using the Nyquist diagrams and the system stability constraint condition can be obtained based on the Nyquist stability criterion. Moreover, impact analysis of the control parameters on the current loop performance, that is, steady-state error and stability margin, identifies that different control parameters play different decisive roles in current loop performance. Based on the analysis, a simplified controller design method based on the system specifications is proposed. Following the method, two design examples are given, and the experimental results verify the practicability and feasibility of the proposed design method.

Analysis and Design of Interleaved Boost Power Factor Corrector on Two Stage AC/DC PFC Converter (2단 역률보상회로를 구성하는 Interleaved 승압형 컨버터의 해석 및 설계)

  • 허태원;손영대;김동완;김춘삼;박한석;우정인
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제52권7호
    • /
    • pp.343-351
    • /
    • 2003
  • In this paper, interleaved boost converter is applied as a first-stage converter in switch mode power supply. The first-stage converter plays a role to improve power factor. Interleaved Boost Power Factor Corrector(IBPFC) can reduce input current ripple as a single voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. Each converter cell is also operated in discontinuous current mode and inductor current of each converter is discontinuous. Total input current which is composed by each converter cell is continuous current. Thus, IBPFC is able to improve input current ripple. IBPFC operating in discontinuous current mode can be classified as six modes from switching state and be carried out state space averaging small signal modeling. A control transfer function is obtained according to the modeling. Not only steady-state characteristics but also dynamic characteristics is considered. Single voltage control loop is also constructed by the control transfer function. From experimental result, improvement of power factor and input current ripple are verified.

Analysis of the Leakage Current in Poly Si TFTs (다결정 실리콘 박막트랜지스터의 누설전류 해석)

  • Lee, In-Chan;Ma, Tae-Young;kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.801-802
    • /
    • 1992
  • Poly Si TFTs have been fabricated from low temperature annealed a-Si films. I-V and C-V characteristics in the off-state region were measured. Analytical model for the leakage current in the off-state was suggested. In the measurement, capacitance increased abruptly with Increasing gate and drain voltage. This phenomena is attributed to the leakage current.

  • PDF

A study on the analysis and design of the chopper fed DC Motor control system using state space averaging method (상태평균화법에 의한 직류초퍼구동 DC모터 제어시스템의 해석과 설계에 관한 연구)

  • Yu, Gwon-Jong;Kim, Yong-Ju;Kim, Han-Sung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.352-356
    • /
    • 1990
  • In this paper proposed a new analysis method that can be controlled DC separately excited motor using DC chopper. An analysis method can be broadly divided the state variables method and the state space averaging method. The state variable method is largely used for analysis method in the time area, but it is complicated analysis of the nonlinear circuit and modeling of the system. Therefore a boundary of the current continuous mode and discontinuous mode can be definited by the state space averaging method. Also this paper proposed a new approximation analysis method using state space averaging method in the discontinuous mode.

  • PDF