• Title/Summary/Keyword: current state analysis

Search Result 1,820, Processing Time 0.028 seconds

The Initial Magnetic Field Decay of the Superconducting Magnet in the Persistent Current Mode (초전도자석의 영구전류모드 운전시 초기자장감쇠)

  • 배준환;심기덕;권영길
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.31-34
    • /
    • 2000
  • this paper deals with the initial magnetic field decay for a large scale superconducting magnet e.g. NMR/MRI magnet. The high resolution image can not be obained during the periods of the initial field decay. It is known that all superconducting materials have the property of diamagnetism. This diamagnetism is usually explained with the concept of screening current. We assumed that the existence of the screening currebt. we assumed that the existence of the screening current makes the current distribution in the superconducting wire non-uniform. And the initial magnetic field decay is caused steady current state in the view of its pattern. The initial magnetic field decay is caused by the change of the current distribution between the energizing state and persistent current mode. in this paper the theoretical analysis for the current distributions has been introduced for each state. The experiments have been carried out to verify transport currents in order to veperiments, it small at the higher transport current.

  • PDF

An Analysis of Current State of Grounded Theory Methodology in Korean Information Systems Research with Suggestion of its Application Guidelines (우리나라 정보시스템 연구에서 근거이론방법론 현황 분석과 적용 지침 제시)

  • Lee, Woong-Kyu
    • The Journal of Information Systems
    • /
    • v.29 no.1
    • /
    • pp.181-199
    • /
    • 2020
  • Purpose The purpose of this study is to analyze the current state of grounded theory methodology in Korea information systems studies and to suggest its application strategies. Design/methodology/approach After reviewing previous studies, this study reviewed 16 papers which adopted grounded theory methodology and analyzed these papers by two ways, research contents and methods adopted from grounded theory methodology: Main characteristics in grounded theory methodology are selected as main criteria in analysis such as data collection method, constant comparison, software use, coding ways, suggested model, proposition suggestion etc., while subject, theory/practice orientation, and role of prior knowledge are included in research contents. Findings Based on the review and analysis, this paper suggested four guidelines for adopting grounded theory methodology to information systems research in Korea: First, division of research methodology into stages. Second, explicit documentation of research process. Third, pursuit of diversity in research topics. Fourth, strengthening scale up and theoretical integration.

Quasi-Steady-State Analysis on the Effect of the STATCOM on FRT Performance of Fixed Speed Wind Turbines (준정상상태 해석을 통한 고정속 풍력 발전기의 FRT에 대한 STATCOM의 효과 분석)

  • Ahn, Seon-Ju;Hwang, Pyeong-Ik;Nam, Soon-Ryul;Kang, Sang-Hee;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.686-692
    • /
    • 2010
  • This paper analyzes the effect of the STATCOM on the improvement of the Fault Ride Through (FRT) capability of the fixed speed wind turbines(FSWTs). The steady-state models of the wind farm components, such as induction generator, capacitor bank, and the STATCOM, are developed based on the simplified equivalent circuit. Especially, the STATCOM is modeled as a controllable current source and a method that analytically determines the magnitude of the injection current is developed. For the quasi-steady-state(QSS) analysis, the steady-state model of the generator and STATCOM are merged with the dynamic model of drive train. The QSS simulation with the STATCOM shows that the STATCOM can enhance the FRT performance by improving the $W_r-T_e$ characteristics of the FSWTs.

Simulation of Thermal Trip in Mill Driver (과부하 운전 압연용 전동기의 과열 정지 시뮬레이션)

  • Lee SeungHee;Han Muho;Lee Wangha;Lee Chiwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.288-291
    • /
    • 2001
  • In steel plant, load torque of mill driver motor is changed periodically because working state and idle state are repeated and load current of working state is necessarily higher than rated motor current. The over current limiter is one of the basic thermal protection method from over heating. In this paper, we analyzed the structure of over current limiter for motor and motor driver systems, developed over current limiter with same operation and structured warning system of action of over current limiter. As using this warning system, we can avoid abrupt plant stop by over current limiter in mill driver and lessen producing loss by plant stop. The developed warning system of action of over current limiter is exactly inspected by computer simulation md analysis of acquired data.

  • PDF

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

Direct Current Control Method Based On One Cycle Controller for Double-Frequency Buck Converters

  • Luo, Quanming;Zhi, Shubo;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.410-417
    • /
    • 2012
  • In this paper, a direct current control method based on a one-cycle controller (DCOCC) for double frequency buck converters (DF buck) is proposed. This control method can make the average current through the high frequency and low frequency inductors of a DF buck converter equal. This is similar to the average current control method. However, the design of the loop compensator is much easier when compared with the average current control. Since the average current though the high frequency and low frequency inductors is equivalent, the current stress of the high frequency switches and the switch losses are minimized. Therefore, the efficiency of the DF buck converter is improved. Firstly, the operation principle of DCOCC is described, then the small signal models of a one cycle controller and a DF buck converter are presented based on the state space average method. Eventually, a system block diagram of the DCOCC controlled DF buck is established and the compensator is designed. Finally, simulation and experiment results are given to verify the correction of the theory analysis.

Stability Analysis ofn HTS Current Lead with Constant Safety Factor (안전율이 일정한 초전도 전류도입선의 안정성해석)

  • Seol, Seoung-Yun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.15-19
    • /
    • 2000
  • The stability of variable cross-sectional area HTS current lead is considered. The cross-sectional area is varied to have a constant safety factor which is defined as the ratio of operating current and critical current of superconductor. As the constant area HTS lead, the variable cross-sectional area HTS lead also has three steady states above the bifurcation point and only one steady state below the bifurcation point. The temperature profiles and current sharing ratios for each steady state are calculated. The heat dissipation into cryogenic system for super-conducting, intermediate, and upper states are compared. For Bi-2333 sheathed with silver-gold alloy 2m length of current lead, and the maximum temperature of upper state seems to be burn-out free below 5m length.

  • PDF

The Analysis and Compensation of DC to DC Converter with Current Mode Controller (전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구)

  • 김철진;김영태;송요창
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

Analysis on the Current State of Batterer Intervention Programs (가정폭력 가해자 개입 프로그램 실태분석)

  • 김경신;김정란
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.10
    • /
    • pp.117-132
    • /
    • 2000
  • The purpose of this study was to analysis on the current state of batterer intervention programs in South Korea. This study was composed of two parts. First, intervention programs for domestic violence batterer in foreign countries were reviewed. Second, bitterer programs in South Korea were explored. In order to expand these bitterer programs in South Korea, culturally appropriate intervention, more innovative research on comparison analysis of diverse intervention approaches, program impact, type of curriculum, and intervention protocol, evaluation criteria, requirements pertaining to program facilitators, political assistance, and coordinated community response and community service are strongly needed.

  • PDF

Analysis and Design of the In-Rush Current Protection Circuit for SSPA Power Supply (SSPA용 전원공급기의 돌입전류 보호회로 분석 및 설계)

  • Park, Sang-Hyun;Park, Dong-Chul;Kim, Dae-Kwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.5-11
    • /
    • 2008
  • Recently developed radars use the solid-state power amplifier to amplify the RF signal. The stability of RF signal directly depends on that of the electric power. So the stable and reliable electric power should be needed. When the electric power switch is tuned on for the first time in order to operate the radar system, the in-rush current is generated because of the capacitive characteristic. The excess in-rush current breaks the element. Therefore, the analysis about the in-rush current to design the electric power system is necessary. In this paper, modeling and simulation on the whole power system is carried out and the necessity of limiting the in-rush current is verified. After the analysis, the circuit to limit the in-rush current is designed and examined to verify the analysis. The circuit is good enough to limit the in-rush current.