A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제15권2호
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

High Performance Current-Mode DC-DC Boost Converter in BiCMOS Integrated Circuits

  • Lee, Chan-Soo;Kim, Eui-Jin;Gendensuren, Munkhsuld;Kim, Nam-Soo;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.262-266
    • /
    • 2011
  • A simulation study of a current-mode direct current (DC)-DC boost converter is presented in this paper. This converter, with a fully-integrated power module, is implemented by using bipolar complementary metal-oxide semiconductor (BiCMOS) technology. The current-sensing circuit has an op-amp to achieve high accuracy. With the sense metal-oxide semiconductor field-effect transistor (MOSFET) in the current sensor, the sensed inductor current with the internal ramp signal can be used for feedback control. In addition, BiCMOS technology is applied to the converter, for accurate current sensing and low power consumption. The DC-DC converter is designed with a standard 0.35 ${\mu}m$ BiCMOS process. The off-chip inductor-capacitor (LC) filter is operated with an inductance of 1 mH and a capacitance of 12.5 nF. Simulation results show the high performance of the current-sensing circuit and the validity of the BiCMOS converter. The output voltage is found to be 4.1 V with a ripple ratio of 1.5% at the duty ratio of 0.3. The sensing current is measured to be within 1 mA and follows to fit the order of the aspect ratio, between sensing and power FET.

A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method (교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구)

  • Park, Jae-Seok;Song, Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

Design of A High-Speed Current-Mode Analog-to-Digital Converter (고속 전류 구동 Analog-to-digital 변환기의 설계)

  • 조열호;손한웅;백준현;민병무;김수원
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • 제31B권7호
    • /
    • pp.42-48
    • /
    • 1994
  • In this paper, a low power and high speed flash Analog-to-Digital Converter using current-mode concept is proposed. Current-mode approach offers a number of advantages over conventional voltage-mode approach, such as lower power consumption small chip area improved accuracy etc. Rescently this concept was applied to algorithmic A/D Converter. But, its conversion speed is limited to medium speed. Consequently this converter is not applicable to the high speed signal processing system. This ADC is fabricated in 1.2um double metal CMOS standard process. This ADC's conversion time is measured to be 7MHz, and power consumption is 2.0mW, and differential nonlinearity is less than 1.14LSB and total harmonic distortion is -50dB. The active area of analog chip is about 350 x 550u$m^2$. The proposed ADC seems suitable for a single chip design of digital signal processing system required high conversion speed, high resolution small chip area and low power consumption.

  • PDF

$J_{c}$ control ofNb/$Al_{2}$$O_{3}$ /Nb Josephson junction (Nb/$Al_{2}$$O_{3}$ /Nb 조셉슨 접합의 임계전류밀도 제어)

  • 김규태;홍현권;이상길;이규원
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.10-12
    • /
    • 2002
  • Single Josephson junctions of 50 $\mu$m $\times$ 50 $\mu$m were fabricated for several oxidation conditions to investigate controllabilities of critical current density ($J_{c}$) with the standard KRISS processes. Considering the self-field effect suppressing the observed critical current ($I_{c}$) at high $J_{c}$ region, we could reasonably estimate $J_{c}$ values from I-V observations. The dependence of the estimated $J_{c}$ as a function of exposure, which is equal to pressure(P) times time(t), was well fitted to a curve of $J_{c}$ ~ $(Pt)^{-0.36}$. The maximum $J_{c}$ value at the controllability margin was found to be 4 kA/$cm^{2}$ with the current equipment set up.

  • PDF

A Research on Dielectric Characteristics of Small Current Interruption Considering Pre-Condition Test for Puffer Type Circuit Breaker (Pre-Condition 시험을 고려한 Puffer식 차단기의 진상소전류 차단성능에 관한 연구)

  • Ahn, Heui-Sub;Yoon, Jeong-Hoon;Lee, Jong-Chul;Choi, Jong-Ung;Oh, Il-Sung;Lee, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2003
  • This paper presents the small current interruption capability of $SF_6$ puffer circuit breaker considering pre-condition. Firstly, the change of dielectric strength of the 3 breakers was compared with testing breakers as clean contacts and eroded contacts after 3 shots of 760 according to new IEC 62271-100 standard. Also the dielectric strength curve of each model was calculated through flow and electric field simulations. From these results, we could modify the empirical equation, being used to predict the dielectric strength of small current interruption capability, considering the effects of pre-condition.

  • PDF

A Study on the Current State and Policies for Standardization on Electronic Commerce (전자상거래 표준화 현황 및 정책 분석에 관한 연구)

  • 박윤정;임춘성;윤용기
    • Journal of Information Technology Applications and Management
    • /
    • 제10권3호
    • /
    • pp.23-44
    • /
    • 2003
  • It is needed to search the electronic commerce standardization and to analysis its policies to meet the international situations strategically and forecast the technology surroundings for electronic commerce. This study aims at searching the current state of electronic commerce standardization and analyzing policies on electronic commerce by the driving subject, that is, government and private organization, major countries, and standard classifications of electronic commerce technologies such as e-documents, e-catalog, e-payment, and e-process. The government and private organizations get information for the current state and policies for standardization on electronic commerce and put them practical use to make policies and strategy applications.

  • PDF

A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility (침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • 제17권3호
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

The gate delay time and the design of VCO using variable MOS capacitance

  • Ryeo, Ji-Hwan
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.99-102
    • /
    • 2005
  • In the paper, a proposed VCO based on bondwire inductances and nMOS varactors was implemented in a standard $0.25\;{\mu}m$ CMOS process. Using the new drain current model and a propagation delay time model equations, the operation speed of CMOS gate will predict the dependence on the load capacitance and the depth of oxide, threshold voltage, the supply voltage, the channel length. This paper describes the result of simulation which calculated a gate propagation delay time by using new drain current model and a propagation delay time model. At the result, When the reverse bias voltage on the substrate changes from 0 voltage to 3 voltage, the propagation delay time is appeared the delay from 0.8 nsec to 1 nsec. When the reverse voltage is biased on the substrate, for reducing the speed delay time, a supply voltage has to reduce. The $g_m$ value of MOSFET is calculated by using new drain current model.

  • PDF

Development of Leakage Current Sensing Controller in Consideration of Industrial EMS (산업용 EMS를 고려한 누설전류 센싱 컨트롤러의 개발)

  • Park, Sung-Won;Roh, Inh-Bae;Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.70-71
    • /
    • 2009
  • In recent years, a importance of EMS(Electromagnetic Susceptibility) is increased with the spread of a communication device significantly. The compatibility of EMS is evaluated by conduction and radiation of EMI(Electromagnetic Interference). In this paper, a leakage current sensing controller which is considered of industrial EMS is developed. The developed system is consisted of power module, sensing module of leakage current, processer module, display module and communication module. The developed system is evaluated the compatibility of EMS by conduction and radiation of EMI. In evaluation results, the developed system is compatible to the standard of industrial EMS.

  • PDF