• Title/Summary/Keyword: current standard

Search Result 3,825, Processing Time 0.032 seconds

A study of Determination of Frost penetration Depth in incheon Area (인천지역의 동결깊이산정에 관한 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.5-6
    • /
    • 2015
  • Recently, freezing index of frost penetration depth estimation used in Korea is applied according to the standard, published by MOLIT in 2003. However, it is difficult to consider can not be determined to standard reflects weather conditions in accordance with the current climate warming or abnormally high temperature. Also the temperature should be considered local variables because heavy local gap. Therefore, this study is through the freezing index presented in MOLIT's code by calculating the frost penetration depth determining whether the adequacy and conducted a study to apply in the field. As a result, when the Elevation 100m to standard in Incheon frost penetration depth is found to be 50.8cm.

  • PDF

Power Load Density Analysis considering Structure and Characteristics of Subway Stations (지하철 역사의 구조 및 특성을 고려한 동력부하밀도 분석)

  • Jung, Hyun-Ki;Cha, Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.912-920
    • /
    • 2006
  • The purpose of this study is to present the design standard for load density in subway station. From the data of electric equipment capacity and electric power consumption for 43 subway stations, current levels of the load density and excess capacity factor were surveyed and analyzed, In addition mean value, standard deviation, maximum value, median value and correlation coefficient were evaluated through excel program. Also it was carried out the regression analysis. The estimation method of load density and design criterion were studied. As a result, load density in this thesis have been proposed : 51.3 $[VA/m^2]$ on the general power load can be a standard value for subway station.

  • PDF

A Study on Recycling of Waste Tire (폐타이어 재 자원화를 위한 연구)

  • 이석일
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.38-44
    • /
    • 2000
  • Compared to other waste, waste tire has much discharge quantity and calorie. When we use waste heat from waste tire, it can be definitely better substitute energy than coal and anthracite in high oil price age. To use as a basic data for providing low cost and highly effective heating system, following conclusion was founded. Annual waste tire production was 19,596 million in 1999, Recycling ratio was almost 55% and more than 8.78 million was stored. Waste tire has lower than 1.5% sulfur contain ratio which is resource of an pollution, So it is a waste fuel which can be combustion based on current exhaust standard value without any extra SOx exclusion materials. Waste tire has 9,256Kcal/kg calorific value and it is higher than waste rubber, waste rubber, waste energy as same as B-C oil. When primary and second air quantity was 1.6, 8.0 Nm$^3$/min, dry gas production time was 270min and total combustion time was 360 min. In the SOx, NOx, HC of air pollution material density were lower than exhaust standard value at the back of cyclone and dusty than exhaust standard value without dust collector.

  • PDF

A Study on the Design Standard of Substation Facility Density and Demand Factor in Office Buildings (사무소용건물의 변전시설밀도 및 수용률 기준설정에 관한 연구)

  • 김세동;정동효
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.42-48
    • /
    • 1992
  • This paper shows a reasonable design standard of substation facility density and demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates an be contributed by the application of the design standard must be applied by the revision of current regulations and laws.

  • PDF

Developing a Standard Costing Model for a Container Terminal and Their Profitability Analysis case study of with reference to PECT and GCT (컨테이너부두의 표준원가모델 구축 및 운영수지분석)

  • 임종길;이태우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.19-33
    • /
    • 1999
  • This paper is concerned with developing a standard costing model based on the case study of PECT and GCT and analysing their profitability in order to improve operation efficiency and design business strategy. In doing so, the model can be a useful tool to analyze current calculation system of lease charge at the two terminals and to judge whether the level of lease charge currently applied to them is justifiable for their profitability. This paper also deals with break-even analysis of container terminal operating companies on the basis of the model and forecast of their profitability. On the top of that, it tries to look into the arguments and to suggest proposals for improving their profitability.

A Study on the Theory and Historical Development of Official Document Classification Scheme in Korea - Since Chosun Dynasty to Current Korea Government - (문서분류의 이론과 변천에 관한 연구 - 조선조이후 현행 '정부공문서분류'까지 -)

  • Choe, Jung-Tai;Lee, Ju-Yeon
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.3 no.2
    • /
    • pp.1-33
    • /
    • 2003
  • This study is to aim on the theory of document classification system and historical development of official document classification scheme since Chosun dynasty to Republic of Korea. We have been new version of classification scheme 'Document Classification Standard' is scheduled in 2004, though there are many fundamental problems in governmental agencies and record centers. Thus new 'Document Classification Standard' should be make discussion and inquire.

ISO 26262 and ISO/PAS 21448 as Exemption Clauses of Product Liability (제조물 책임 면책 수단으로서의 ISO 26262와 ISO/PAS 21448)

  • Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.346-349
    • /
    • 2019
  • Product liability is an important regulation factor in automotive industry. ISO 26262 international standard was established as an exemption clause of product liability. In autonomous car, product liability becomes more important, and ISO/PAS international standard was additionally established, but it can be applied to only sensing stage, which can partly make the autonomous car companies exempt the product liability but not completely. Therefore, reform of current legal system is absolutely necessary to commercialize autonomous car until a new international standard is established as a complete exemptions clause.

A Study on the Changing Factors in Cost Estimate Standard for Reinforced Concrete Structure Maintenance (철근콘크리트 구조물 유지보수 공사비산정기준 개정요인에 관한 연구)

  • Song, Tae-Seok;An, Bang-Yul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.315-316
    • /
    • 2021
  • The proportion of maintenance work has been increasing due to the recent aging of the infrastructure, but the standardized construction cost estimation standards are insufficient for this. In particular, reinforced concrete structures are being applied to many structures such as buildings and bridges, and various construction methods for maintenance of reinforced concrete structures are being developed and applied. In this study, we surveyed about the current status of the construction method for the maintenance work of reinforced concrete structures and analyze the factors of the revision of the construction cost estimate standard for the reinforced concrete structure maintenance.

  • PDF

Improvement of the Conductor Temperature Calculation Algorithm for Calculating the Allowable Current in the Underground Channel (지중관로에서의 실제 허용전류 산출을 위한 도체온도 계산 알고리즘 개선에 관한 연구)

  • Lee, Hyang-Beom;Lee, Byung-Chul;Kim, Jung-Hoon;Nam, Yong-Hyun;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.352-357
    • /
    • 2018
  • In this paper, the improvement of the conductor temperature calculation algorithm is studied. The allowable current of the underground transmission line is determined by the conductor temperature limit. Usually to calculate the allowable current limit, the conductor temperature is assumed in the most worst environment condition. It is possible to increase the transmission capacity if the actual burial environment is considered. Therefore, in this paper an algorithm is proposed to calculate the conductor temperature by distinguishing two area of a underground transmission line condition - the manhole where the temperature sensor can be installed and the underground transmission line in which the temperature sensor can not be installed easily. When calculating the conductor temperature by the underground line in the pipeline, the existing standard describes each environment as a single soil heat resistance and one ambient temperature. In order to compensate this situation, thermal resistance model that can take into consideration the ground surface temperature and under ground temperature is proposed. It is shown that the accuracy of the proposed model is increased compared with the existing standard calculation result.

Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod (탄소블록과 동봉의 접지임피던스 비교 분석)

  • Seo, Jae-Suk;Park, Hee-Chul;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.