• Title/Summary/Keyword: current standard

Search Result 3,825, Processing Time 0.04 seconds

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

Effective Stiffness of Circular Reinforced Bridge Columns (철근콘크리트 원형단면 교각의 유효강성)

  • 배성용;김준범;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.833-838
    • /
    • 2001
  • The objectives of this study are to investigate effective stiffness of circular reinforced bridge columns and to provide reasonable effective stiffness equations for seismic design to the current Korean Bridge Design Standard. The material nonlinear analysis was conducted for 5184 columns of which variables were the concrete compressive stress, the steel yielding stress, the longitudinal steel location parameter, the longitudinal steel ratio, the axial load level, and the diameter of section. The current Korean Bridge Design Standard generally used the gross section stiffness because of unclear provision, it may be non-conservative because of being evaluated greater design seismic force and less design displacement than those of the abroad provision. Therefore, the proposed effective stiffness equations include three variables such as : the longitudinal steel location parameter, the longitudinal steel ratio, and the axial load ratio. Two equations of effective stiffness are proposed which may be used for earthquake force estimation and for earthquake displacement estimation, respectively.

  • PDF

Evaluation for Standard Current Transformers and Current Transformers under Test Using Precise Standard Resistors (정밀저항을 이용한 표준 변류기와 피측정 변류기의 평가)

  • Song, Eui-Sup;Kim, Yoon-Hyoung;Jung, Jae-Kap
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2083_2084
    • /
    • 2009
  • 본 연구에서는 변류기 비교측정 시스템과 정밀저항을 이용 하여 변류기의 오차에 연관되는 인자를 측정함으로써 피측정 변류기의 절대 평가를 하고 그 결과를 이용하여 표준 변류기를 평가 하였다. 한편 기존에 60 Hz 에 적용하였던 실험을 이번 실험에서는 60 Hz 뿐만 아니라 50 Hz 까지 확장하여 실험 하였다. 이 기술의 타당성을 검증하기 위해 실험에 사용된 동일한 변류기에 대한 해외 국가 표준기관의 비오차 및 위상오차와 비교 하였고 그 차이값이 확장 불확도 내에서 일치 함을 확인 하였다.

  • PDF

An Intonation Study of Predicate ending in Current Korean - From final endings of ${\ulcorner}$-a/e, $t{\int}ijo$${\lrcorner}$ and ${\ulcorner}$p/simnida${\lrcorner}$ - (현대 서울말 평서문에 나타나는 억양 연구 - 어말어미 "-아/어, -지요" 와 "-ㅂ/습니다" 를 중심으로 -)

  • Yu, Ki-Won
    • Proceedings of the KSPS conference
    • /
    • 2005.04a
    • /
    • pp.3-7
    • /
    • 2005
  • This research is for finding prototypes and characteristics of intonation found in ${\ulcorner}$-a/e, $t{\int}ijo$<${\lrcorner}$ and ${\ulcorner}$p/simnida${\lrcorner}$ among modern Korean predicate statements by constructing spoken corpus based on the current radio broadcast. So the result of the study is as follows. : (1) The construction of the balanced spoken corpus and the standard for boundary determination of rhythm are needed for the intonation model of speech synthesis. (2) Korean intonation units have the splited word tone which includes the nuclear tone and the pre-nuclear tone makes unclear tone more detailed. (3) I made man and woman intonation models individually through t-test of SPSS. (4) The standard intonation model is devided '-ajo'type and '-nida'type

  • PDF

Electrodeposition of Chromium from Chromiun(III) Sulfate Complexes in Aqueous Solutions (황산크롬(III) 착화합물 수용액으로부터의 크롬전착)

  • 고석수;송진태
    • Journal of the Korean institute of surface engineering
    • /
    • v.21 no.4
    • /
    • pp.149-159
    • /
    • 1988
  • Electrodeposition of chromium from low concentration chromjum (III) sulfate complexess in aqueous using sodium formate-glycine mixtures as a complexing agent was studied. In the bath formation, it is found that the optimum again temperature and time for equilibration of the electrolytes are nrcessary for 24 hrs at 45$^{\circ}C$and the optimum elecrical charge for low current electrolysis which might be produced Cr(II) ions in the electrolytes is necessary for minum 2Ah/$\ell$. The optmun concentration off standard electrolyte for main composition is 0.05M chromium(III) sulfate, 0.2M sodium formate-0.2M glycine, and I mMNaSCN as a catalysea, respectivwly. The standard electrolyte is shows good covering, good throwing power, and 6% of current efficiency (Cr(III)basis). The oppearance of electrodeposits shows att active bright chromium. The SEM morphology of the chromjum coating is observed as smooth surfaces and dispersed micro prcro pores. X-ray diffraction analysis shows a bcc structure which the perferred orintation of the chromium electrodeposits is strongin(200)plane.

  • PDF

Analog Signal Conditioner Using Fuzzy Logic Technique

  • Maipradith, N.;Riewruja, V.;Chaikla, A.;Julsereewong, P.;Ukakimaparn, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.472-472
    • /
    • 2000
  • An analog signal conditioner using fuzzy logic technique, which has multiple-input and multiple-output terminals, is proposed in this paper. The proposed signal conditioner can be employed to linearly translate the level of signals to a standard voltage signal (1-5V) and convert the form of signals to a standard current signal (4-20mA). The implementation method based on the use of a commercial 8-bit microcontroller, the analog-to-digital (A/D) converters, the digital-to-analog (D/A) converters and the voltage-to-current (V/I) converter. The simulation result and the experimental results are presented, which further confirm the feasibility of this approach.

  • PDF

A Framework for MPEG-4 Contents Delivery over DMB

  • Lee, Bong-Ho;Yang, Kyu-Tae;Hahm, Young-Kwon;Lee, Soo-In;Ahn, Chie-Teuk
    • ETRI Journal
    • /
    • v.26 no.2
    • /
    • pp.112-121
    • /
    • 2004
  • Digital Multimedia Broadcasting (DMB) is an upcoming standard in Korea used to provide mobile multimedia broadcasting service based on the Eureka-147 Digital Audio Broadcasting (DAB) system. The current dominant multimedia coding standard, MPEG-4, is foreseen to play an important role in forthcoming DMB services. However, the current approaches for transporting MPEG-4 content over DMB networks are not optimized. To address this issue we propose a novel MPEG-4 stream multiplexer, called M4SMux, which provides better stream multiplexing and delivery over DMB networks. M4SMux features an MPEG-4 elementary-stream interleaving mechanism that reduces the multiplexing overhead and a multiplex configuration mechanism that utilizes M4SLinkTable for easy content access. In addition, we propose an error correction method which enhances transport efficiency.

  • PDF

Exchange of CAD Part Models Based on the Macro-Parametric Approach

  • Choi, Guk-Heon;Mun, Du-Hwan;Han, Soon-Hung
    • International Journal of CAD/CAM
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • It is not possible to exchange parametric information of CAD models based on the current version of STEP. The design intent can be lost during the STEP transfer of CAD models. The Parametrics Group of ISO/TC184/SC4 has proposed the SMCH schema, which includes constructs for exchange of parametric information. This paper proposes a macro-parametric approach that is intended to provide capabilities to transfer parametric information including design intents. In this approach, CAD models are exchanged in the form of macro files. The macro file contains the history of user commands, which are used in the modeling phase. To exchange CAD models using the macro-parametric approach, the modeling commands of several commercial CAD systems are analyzed. Those commands are classified and a set of standard modeling commands has been defined. Mapping relations between the standard modeling commands and the native modeling commands of commercial CAD systems are defined. The scope of the current version is limited to parts modeling, not assemblies.

A Study on the Apply to Soil Thermal Resistivity of Low-Voltage Underground Power Cables (저압 지중케이블의 토양 열저항률 적용에 관한 연구)

  • Lee, Joo-Chul;Kim, Ki-Hyun;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.65-70
    • /
    • 2012
  • The current-carrying capacities in IEC standards for underground refers to a soil thermal resistivity of 2.5[$K{\cdot}m/W$] where no measured data are available. But this value is considered too conservative and may not justifiable economically as to need precaution in using the value. In this paper, the standard practices on the application of soil thermal resistivity of some countries(UK, USA etc) are surveyed and proposed a reasonable representative value 1.0[$K{\cdot}m/W$] of soil thermal resistivity considering the domestic soil thermal properties with regard to the application of IEC standard.

Validation of Ocean Color Algorithms in the Ulleung Basin, East/Japan Sea

  • Yoo, Sin-Jae;Park, Ji-Soo;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.4
    • /
    • pp.315-325
    • /
    • 2000
  • Observations were made to validate ocean color algorithms in the Ulleung Basin, East Sea in May 2000. Small scale and meso-scale surveys were conducted for the validation of ocean color products (nLw: normalized water-leaving radiance and chlorophyll concentration). There were discrepancies between SeaWiFS and in situ nLw showing the current aerosol models of standard SeaWiFS processing software are less than adequate (Gordon and Wang, 1994). Applying the standard SeaWiFS in-water algorithm resulted in an overestimation of chlorophyll concentration. This is because that CDOM absorption was higher than the estimated chlorophyll absorption. TSS concentration was also high. Therefore, the study region deviated from Case 1 waters. The source of these materials seems to be the entrainment of coastal water by the Tsushima Warm Current. Study of the bio-optical properties in other season is desirable.