• Title/Summary/Keyword: current pulse

Search Result 1,867, Processing Time 0.022 seconds

Fabrications and Properties of MFIS Structures using high Dielectric AIN Insulating Layers for Nonvolatile Ferroelectric Memory (고유전율 AIN 절연층을 사용한 비휘발성 강유전체 메모리용 MFIS 구조의 제작 및 특성)

  • Jeong, Sun-Won;Kim, Gwang-Hui;Gu, Gyeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.11
    • /
    • pp.765-770
    • /
    • 2001
  • Metal-ferroelectric-insulator- semiconductor(MFTS) devices by using rapid thermal annealed (RTA) LiNbO$_3$/AIN/Si(100) structures were successfully fabricated and demonstrated nonvolatile memory operations. Metal-insulator-semiconductor(MIS) C-V properties with high dielectric AIN thin films showed no hysteresis and good interface properties. The dielectric constant of the AIN film calculated from the capacitance at the accumulation region in the capacitance-voltage(C-V) characteristics was about 8. The C-V characteristics of MFIS capacitor showed a hysteresis loop due to the ferroelectric nature of the LiNbO$_3$ thin films. Typical dielectric constant value of LiNbO$_3$ film of MFIS device was about 23. The memory window width was about 1.2 V at the gate voltage of $\pm$5 V ranges. Typical gate leakage current density of the MFIS structure was the order of 10$^{-9}$ A/$\textrm{cm}^2$ at the range of within $\pm$500 kV/cm. The ferroelectric capacitors showed no polarization degradation up to about 10$^{11}$ switching cycles when subjected to symmetric bipolar voltage pulse(peak-to-peak 8 V, 50 % duty cycle) in the 500 kHz.

  • PDF

Characteristics of ${\alpha}$-Cyclodextrin Modified Carbon Paste Electrode (${\alpha}$-Cyclodextrin으로 화학수식된 Carbon Paste 전극의 특성)

  • Jeon, Young-Guk;Kim, Bong-Weon;Kim, Hee-Jung;Cho, Young-Dal;Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.235-243
    • /
    • 1996
  • A carbon paste electrode were chemically modified using ${\alpha}$-cyclodextrin. Characteristics of chemically modified carbon paste electrodes were studied on the basis of the inclusion complex formation of ${\alpha}$-cyclodextrin and p-nitrophenol in solution. Cyclic voltammetry and differential pulse voltammetry were used to monitor the efficiency of the chemical modification. When the ${\alpha}$-cyclodextrin and carbon powder ratio of 2 : 1 in weight were used, the reduction peak current of p-nitrophenol was decreased almost completely, whereas those of o-nitrophenol and hydroquinone were not changed much. This result is due to the large difference in the inclusion complex formation constants of p-nitrophenol and the other probes with ${\alpha}$-cyclodextrin. Taking advantage of this difference, we can determine the concentration of o-nitrophenol even in the presence of p-nitrophenol.

  • PDF

The Effect of Grain Size and Cooling Rate on Phase Transformation for Mechanically Alloyed Ni-36at.%Al Alloy (기계적 합금화된 Ni-36at.%Al 합금의 상변태에 미치는 결정립 크기 및 냉각속도의 영향)

  • Kim, Seong-Uk;Kim, Dae-Geon;Kim, Ji-Sun;An, In-Seop;Kim, Yeong-Do
    • Korean Journal of Materials Research
    • /
    • v.10 no.9
    • /
    • pp.642-647
    • /
    • 2000
  • Nanocrystalline NiAl alloy containing 36at.%Al was synthesized by mechanical alloying (MA). Synthesized powder was sintered by a pulse electric current sintering (PECS) facility. Effecting parameters on the phase transformation were discussed in terms of cooling rate and time spent on heat treatment. The behavior of phase transformation for sintered parts was examined by differential scanning calorimetry (DSC) and X-ray diffraction (XRD) method. Microstructure was observed by scanning electron microscopy (SEM). Martensitic lattice parameter and volume fraction was calculated by direct comparison method in X-ray diffraction analysis.

  • PDF

Evaluation of Material Properties of Concrete Harbour Facilities Using Nondestructive Testing Methods (비파괴시험에 의한 콘크리트 항만시설물의 주요 물성치 평가)

  • Yi, Jin-Hak;Han, Sang-Hun;Park, Woo-Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Recently harbor remodeling projects are seriously considered to enhance the loading and unloading capability of old container terminals and to make decrepit ports as eco-friendly harbor and waterfront spaces in many countries. In such a case, quantitative and qualitative evaluations on concrete harbor facilities are mandatory to determine the current structural integrity condition of aged materials. Once the remodeling project is determined to be carried out, the reusability of individual structural members and facilities including caissons, cell-blocks, and tetra-pods need to be decided based on the simple and economic visual inspection and/or nondestructive testing. In this study, the systematic quantitative evaluation procedure for determining the structural integrity condition and the reusability is studied based the nondestructive testing and evaluation methods. Conventional methods including Schmidt hammer test and ultrasonicpulse velocity methods and elastic wave based methods including impact echo test and surface wave test are applied to the old harbor facilities in five different sites. The compressive tests are also carried out to determine the elastic modulus and compressive strength of concrete materials.

Discharge Characteristics of Logic Gate for Discharge Logic Gate Plasma Display Panel (방전 논리게이트 플라즈마 디스플레이 패널의 논리게이트 방전특성)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.9-15
    • /
    • 2005
  • In this research the discharge characteristics of logic gate of the discharge logic gate plasma display panel with the NOT-AND logic function newly designed was analyzed. As for this discharge logic gate a logical output is induced by controlling the voltage between the electrodes using the discharge path. From the experimental result the discharge characteristics of logic gate is influenced by the interrelation of the voltages appling two vertical electrodes. To in the application possibility to large screen PDP, the discharge characteristics by the line resistance of the electrode was evaluated In result it has been inferred that the influence which the drop of voltage by the line resistance of two vertical electrodes exerts on the discharge of the logic gate is minute. Through the experiment, the optimized values of the pulse voltages and the current limitation resistances of each electrode which composed the discharge logic gate were obtained and maximum operation margin of 49[V] was obtained.

Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

  • Menacer, Arezki;Champenois, Gerard;Nait Said, Mohamed Said;Benakcha, Abdelhamid;Moreau, Sandrine;Hassaine, Said
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.219-228
    • /
    • 2009
  • The growing application and the numerous qualities of induction motors (1M) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ${\odot}$ the IM is directly by the balanced three-phase network voltage source, ${\odot}$ the IM is fed by a sinusoidal current source given the controlled by hysteresis, ${\odot}$ the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ${\odot}$ the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

Vibration and Acoustic Noise characteristic on SRM with compensating winding by two stage commutation (2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성)

  • 오석규;이종근;최태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.250-257
    • /
    • 2001
  • SRM drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM drive. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a two stage commutation method during commutation period. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a tow stage commutation method during commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects (Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과)

  • Kim Tae-Youl;Hwang Tae-Yeun;Huh Choon-Bok
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF

Improvement of PENS on Peripheral Nerve Conduction Function in STZ-Induced Diabetic Rats (당뇨유발백서에서 피하신경전기자극의 말초신경기능 개선효과)

  • Kim, Yang-Ho;Chang, Mee-Kyung;Shin, Min-Chul
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.19-26
    • /
    • 2006
  • Purpose: This study aimed the effects of percutaneous electric nerve stimulation (PENS) applied to different parts of the streptozotocin-induced diabetic rats on the change of glucose and nerve. Methods: rats (ten weeks old) were selected as the subjects; the normal group was five rats, and the diabetes induction group II, III and IV were five rats, respectively, which were randomly sampled from the twenty-five streptozotocin-administered rats with more than $240\;d{\ell}/m{\ell}$ of blood sugar. For PENS, electric current with 2 Hz of stimulation frequency and $200\;{\mu}s$ of pulse duration was applied to the subjects for fifteen minutes a day, six days a week, for three weeks. Calculation of glucose and weight, and nerve conduction test were conducted forty-eight hours and three weeks after streptozotocin administration, respectively. Results: As for change of glucose and weight, the group III with stimulation to the acupoints and the group IV with stimulation to non-acupoints showed significant differences from the control group II (p<0.05). As for MNCV (motor nerve conduction velocity), the group III with stimulation to the acupoints showed significant differences from the group IV with stimulation to non-acupoints and the control group II (p<0.05). Conclusion: PENS had the effects of inhibiting increase of glucose, change of weight and decrease of nerve conductive function between the distal and proximal ends of the peripheral nerve in the STZ-induced diabetic rats.

  • PDF

Switching Noise Reduction of Induction Motor by a Two-Phase RCD-PWM Technique with Dual Zero Vector Modes (듀얼 영 벡터 모드를 갖는 2상 RCD-PWM기법에 의한 유도 모터의 스위칭 소음저감)

  • Oh Seung-Yeol;Wi Seog-Oh;Jung Young-Gook;Lim Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.525-535
    • /
    • 2004
  • In this paper, a two-phase DZRCD(Dual Zero Vector Modes RCD) technique is proposed to develope the problem of a conventional two-phase RCD-PWM (Random Centered Distribution PWM) which gives the power spectra of narrow band range in the high modulation index (M). In the proposed DZRCD technique, the zero vector $V_0$ is selected as $V_0$(111) for M$\geqq$0.8. Also, $V_0$ is selected as $V_0$(000) for the modulation indices < 0.8. For the unplementation of the proposed method, a 16-bit micro-controller Cl67 was used and the experiments were conducted with the 1.5kw induction motor under no load condition. The experimental results show that the voltage / current spectra is spread to a wide band range, and the switching noise of motor is reduced by the proposed method compared to the conventional random operation.