• 제목/요약/키워드: current phase

검색결과 5,363건 처리시간 0.033초

3상 인터리브드 양방향 DC-DC 컨버터의 경부하 동작 시 전류 리플 최소화를 위한 스위칭 기법 (Switching Method to Minimize the Current Ripple of 3-Phase Interleaved Bidirectional DC-DC Converter in Light Load Operation)

  • 정재헌;노의철
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.55-62
    • /
    • 2015
  • This paper deals with a switching method to minimize the current ripple component of 3-phase interleaved bidirectional DC-DC converter for charging and discharging of the battery. The characteristics of the output current ripple in 3-phase and 2-phase operation modes according to the variation of battery voltage is analyzed and a phase conversion method for minimizing the magnitude of the current ripple is proposed. The proposed method can extend the light load range because the switching frequency is lower than that of a 3-phase operating system. Simulation and experimental results show the usefulness of the proposed method.

저전압 SR모터의 퍼지로직 기반 전상각 제어 (Fuzzy logic based advance angle control for low voltage SRM)

  • 김규동;신두진;허성재;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.22-25
    • /
    • 2001
  • In this paper, a fuzzy advance angle control method is described to drive an industrial low voltage SRM (Switched Reluctance Motor) for 10kW forklift truck. SRM has a highly non-linear characteristic that is due to change the rotor and stator. And low voltage SRM is designed that its phase resistance and phase inductance is very low to inject high current into the phase windings. In this reason, the proper current control is necessary to drive the low voltage SRM efficiently. SRM has positive torque at increasing inductance region and negative torque at decreasing inductance region. Due to this reason, the current has to be built up in the increasing phase inductance part as soon as possible. Therefore, the phase switch must be turned on before the phase inductance increases, and this angle is called as the advance angle. Also, the phase current has to be dropped before the phase inductance decreases. Fuzzy logic is a flexible and general-purposed method of implementing non-linear functions and as such it is useful in control applications. Consequently, we designed a fuzzy advance angle controller to control the phase current appropriately.

  • PDF

분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

New Permanent Magnet Synchronous Motor Current Sensing Phase Delay Compensation Method

  • Park, Sei-Hun;Kim, Il-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.241-246
    • /
    • 2016
  • This paper presents a method that can improve the performance of permanent magnet synchronous motor current control by minimizing the measured current phase delay caused by the Low Pass Filter(LPF) used to cut off the noises that flowed in when feedback currents are measured. Although existing methods that change the Cutoff Frequency of the LPF can minimize phase delays during high speed rotations, their noise cutoff effects are much lower and this may lead to the decline of control performance. Therefore, in this study, an algorithm that can compensate current phase delays through relatively simple calculations from the synchronous motor d-q axis coordinate transformation matrix and the inverse transformation matrix is proposed and the validity of the proposed method is verified by comparing the waveform of the calculated current with the waveform of actual currents through simulations and experiments.

교류측 센서를 제거한 3상 PWM 정류기의 새로운 제어 (A Novel Control Scheme of Three-Phase PWM Rectifiers Eliminating AC-Side Sensors)

  • 이동춘;이지명;임대식
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.592-600
    • /
    • 2000
  • 본 논문은 직류측 센서만을 갖는 3상 PWM 정류기의 새로운 제어기법을 제안한다. 제어가 내부의 모텔전류와 시스템 전류의 편차를 영으로 제어하여 상전압의 크기와 위상을 추정하고 스위칭 상태와 직류링크전류로부터 상전류를 재구성한다. 제안한 상전압 빛 상전류 센서리스 기법을 PWM 정류기 시스템에 적용한 실험을 통하여 그 타당성을 검증하였다.

  • PDF

직류링크 진류정보를 기반으로 한 SRM 3상전류 추정법 (3-Phase Current Estimation of SRM Based on the DC-Link Current)

  • 김주진;김성곤;김태웅;안진우;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.575-577
    • /
    • 2005
  • This paper proposes the SRM drive system based on DC-link current, from which the phase currents can be estimated in accuracy and also they can be used in driving SRM instead of the three-phase currents. In additional, the detecting circuit for DC-link current is also proposed for increasing the resolution and decreasing the off-set. Comparing to the general drive system based on the phase current, it is verified through the experiment that the proposed SRM drive system has the good performance in steady-state responses of the speed control. Using the DC-link current, all of the 3-phase currents can be easily estimated in driving the SRM.

  • PDF

단상유도전동기의 돌입전류저감을 위한 제어기 설계 (Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor)

  • 박수강;백형래;이상일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

신경회로망을 이용한 SRM의 토오크 제어 (Torque Control Scheme of Switched Reluctance Motor using Neural Network)

  • 정연석;이장선;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.171-174
    • /
    • 1999
  • The torque of SRM is developed by phase currents and inductance variation. Phase currents and inductance variation. Phase current is often the controlled variable in electrical motor drives, so it seems natural to use closed loop current controllers. However, the highly nonlinear nature of switched reluctance motors makes optimisation of closed loop current controlled difficult because of saturation effect in magnetic circuit. Therefore, torque generation region is nonlinearly varied according to phase current and rotor position. This paper describes the torque control scheme with neural network that can control varied with load torque. The torque control is simulated by PSIM.

  • PDF

3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 보상 (The Compensation of the Grid Current Distortion caused by the Grid Voltage Unbalance and Distortion for 3-Phase Bi-Directional DC to AC Inverter)

  • 양승대;김승민;최주엽;최익;송승호;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.228-234
    • /
    • 2012
  • This paper presents the algorithm of the compensation of the grid current distortion caused by the grid voltage unbalance and distortion in 3-phase bi-directional DC to AC inverter. Usually 3-phase grid system has unbalance and distortion because of connecting 1-phase and non-linear load with 3-phase load using same input node. Controlling 3-phase inverter by general method under the unbalanced and distorted grid voltage, the grid current has distortion. This distortion of the grid current cause the grid voltage distortion again. So, it need to control the grid current balanced and non-distorted, even the grid voltage gets unbalanced and distorted. There are some complex method to compensate the gird current distortion. it sugest simple method to solve the problem. PSIM simulation is used to validate the proposed algorithm.