• Title/Summary/Keyword: current phase

Search Result 5,359, Processing Time 0.023 seconds

Phase Current Reconstruction Techniques for Two-Phase Inverters using a Single Current Sensor

  • Cho, Young-Hoon;Cho, Kwan-Yuhl;Mok, Hyung-Soo;Kim, Kyeong-Hwa;Lai, Jih-Shen
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.837-845
    • /
    • 2011
  • This paper proposes phase current reconstruction techniques for two-phase two-leg and two-phase four-leg inverters using a single current sensor. In the proposed methods, one phase current is sampled simultaneously with a particular branch current by using only one current sensor, and then current reconstruction algorithms are applied to extract the information on two phase currents from the sensor output. The sampled current information is periodically updated at the peak and the valley of the triangular carrier waveform in each switching cycle of pulse-width modulation (PWM). The voltage vector spaces where the phase currents can be reconstructed are evaluated. Compared to the existing method using two individual current sensors in two phases, the proposed schemes can save implementation cost since it is possible to remove one current sensor. In addition, the proposed methods are free from gain discrepancy issues between two current sensors. Simulations and experiments show excellent current reconstruction performance of the proposed methods.

A New Three-Phase Current Modulation Method to Suppress the Commutation Torque Ripple of Brushless DC Motor

  • Wang, Zhiqiang;Yin, Shuai;Ma, Tiehua
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1925-1933
    • /
    • 2017
  • The brushless DC motor's commutation torque ripple is caused by inconsistency in the rate of phase current change. Thus, a method that considers armature resistance is proposed to modulate phase current. The three-phase control strategy, which involves the "open-phase conduction, off-phase pulse width modulation, and maintained non-commutation phase" technique, is applied during commutation at full-speed segments of the motor. Changes in each phase current are analyzed theoretically by establishing mathematical model based on phase current to determine the relative difference among shutdown phase, duty, and motor operating parameters. The turn-on and turn-off phase current change rates are made to be consistent to ensure less non-commutation phase current ripple, then the torque ripple is inhibited. The simulation results show that the phase commutation current and torque ripple coefficient of the proposed method are reduced from 56.9% and 55.5% to 6.8% and 6.1%, respectively. In the experiment system, the pulsation coefficient of the motor phase current is reduced from 40.0% to 16.7% at low speed and 50.0% to 18.8% at high speed. The simulation and experimental results show that the proposed control method significantly inhibits commutation current and torque in the full section.

A Study on New Current Control Method for Square Current Wave in Y Connected 7-Phase BLDC Motor Drive System (Y 결선된 7상 BLDC 전동기의 구형파 전류 제어를 위한 새로운 전류 제어방식에 관한 연구)

  • Moon, Jong-Joo;Lee, Won;Kim, Jang-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.576-585
    • /
    • 2016
  • The current control methods of Y-connected 7 Phase BLDC motor are sine wave current control and square wave control. The sine wave current control method needs dq axis transformation of $7{\times}7$ matrix for current control and very complex. Also this method is not suitable for multi Phase BLDC motor of trapezoidal back emf wave. Therefore, in Y connected multi phase BLDC motor, the square wave current control methods are required. Generally, in the 3Phase BLDC system, Average current control method is used for current control. The average current is obtained that the summation of absolute value of each phase current magnitude is divided by the number of conduction phase. However, if average current control method is applied to multi-phase system, there is a problem that each phase currents are different. This problem affects unbalance of each phase torque and fluctuation of total torque. This paper proposed each phase current control method of Y connected 7Phase BLDC system. Proposed method is used for PI controller of each phase for each phase current control. This method can perfect square wave current control. Also, configuration of the method is easier than DQ axis transformation. Proposed method is verified through simulation and experiments.

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types (이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석)

  • Shin-Won Lee;Tae-Hee Han;Sung-Hun Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

A Phase Current Reconstruction Technique Using a Single Current Sensor for Interleaved Three-phase Bidirectional Converters

  • Lee, Young-Jin;Cho, Younghoon;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.905-914
    • /
    • 2016
  • This paper proposes a new phase current reconstruction technique for interleaved three-phase bidirectional dc-dc converters using a single current sensor. In the proposed current reconstruction algorithm, a single current sensor is employed at the dc-link, and the dc-link current information is sampled at either the peak or valley point of the pulse-width modulation (PWM) carriers regularly. From the obtained current information, all phase currents are reconstructed in a single PWM cycle. After that, the digital current controller is applied to achieve current balancing in each phase. Compare to the previous multiple current sensor method, the proposed strategy reduces the number of the current sensors in the interleaved three-phase bidirectional converter as well as reducing potential current sensing error caused by non-ideal characteristics of the multiple current sensors. The effectiveness of the proposed method is verified from the experiments based on a 3kW three-phase bidirectional converter prototype for the automotive battery charging application.

Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.289-293
    • /
    • 2007
  • The fault current limiting characteristics of the separated and the integrated three-phase flux-lock type superconducting fault current limiters (SFCLs) were analyzed. The three-phase flux-lock type SFCL consisted of three flux-lock reactors and three $high-T_c$ superconducting (HTSC) elements. In the integrated three-phase flux-lock type SFCL, three flux-lock reactors are connected on the same iron core. On the other hand, three flux-lock reactors of the separated three-phase flux-lock type SFCL are connected on three separated iron cores. The integrated three-phase flux-lock type SFCL showed the different fault current limiting characteristics from the separated three-phase flux-lock type SFCL that the fault phase could affect the sound phase, which resulted in quench of the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the separated and the integrated three-phase flux-lock type SFCLs according to the ground fault types were compared.

A Study on Current and Torque Characteristics Of Three-Phase Induction Motor in Single-Phase Operation. (삼상유도전동기의 결상시 전류 및 회전력특성에 관한 연구)

  • 유춘식;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.25-33
    • /
    • 1982
  • The characteristics of the stator current and torque of a small three- phase squirrel cage induction motor and studied experimentally under the situation of a single-phase operation due to various causes. Through the experiments, the torque-slip and current-slip curve of single-phase circuit as well as three-phase circuit are obtained and the needed constants are determined. The stator current and torque are calculated by the current and torque equations derived by the unbalanced circuit theory. The numerical values obtained from the above methods are compared with the experimental values under the same conditions. The results of the study are summerized as follow; 1) The values computed by the unbalanced circuit theory generally come to approach the values recorded through experiments. 2) Near the rated load, speed drop is less than 1.2 per cent of the speed of three-phase induction motor and torque reduces less than 3 per cent of it of three-phase induction motor when three-phase induction motor is run under a single-phase. On the other hand, the stator current in a single-phase circuit is more than 1.9 times of it in three-phase circuit. 3) The stalling torque in a single-phase circuit is reduced to about 41 per cent of it in three-phase circuit while the corresponding slip is moved toward the synchroneous speed and the corresponding stator current is increased.

  • PDF

A Study on DC-Link Current Ripple of Multi-Phase/Multi-Stage Boost Converter (다상/다단 부스트 컨버터의 DC-Link 리플 전류 분석)

  • Seung-Min Kim;Dong-Hee Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.59-67
    • /
    • 2023
  • This paper explores the variation of DC-Link current ripple analysis in terms of duty cycle and phase angle of Multi-phase/Multi-stage boost converter. A 2-Stage/1-Stage boost converter DC-Link current is used to determine the difference between the 1st stage diode current and the 2nd stage inductor current. Each stage boost converter diode and inductor current is subordinate to the phase angle and duty cycle. The magnitude of the ripple current is variable according to phase angle and duty cycle. The analysis results are verified by variation of DC-Link current ripple using a 1kW typical 2-stage/1-stage boost converter.

Current Sharing Method Based on Optimal Phase Shift Control for Interleaved Three-Phase Half Bridge LLC Converter with Floating Y-Connection

  • Shi, Lin;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.934-943
    • /
    • 2019
  • A current balance problem exists in multi-phase LLC converters due to the resonant parameter tolerance. This paper presents a current balancing method for interleaved three-phase half bridge LLC converters. This method regulates the phase shift angle of the driving signals between the three phases based on a converter with a floating Y-connection. The floating midpoint voltage has different influences on each phase current and makes the three-phase current balance performance better than midpoint non-floating systems. Phase shift control between modules can further regulate the midpoint voltage. Then three phase current sharing is realized without adding extra components. The current distributions in a midpoint non-floating system and a midpoint floating system are compared. Then the principle and implementation of the proposed control strategy are analyzed in detail. A 3kW prototype is built to verify the validity and feasibility of the proposed method.

Analysis of Fault Current Limiting Characteristics According to Variation of Fault Current level in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (사고전류 변화에 따른 일체화된 삼상자속구속형 고온초전도 사고전류제한기의 사고전류 제한 특성 분석)

  • Han, Byoung-Sung;Park, Chung-Ryul;Du, Ho-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.39-40
    • /
    • 2007
  • The analysis of fault current limiting characteristics according to variation of fault current level in the integrated three-phase flux-lock type superconducting fault current limiter (SFCL), which consisted of three-phase flux-lock reactor wound on an iron core with the same turn's ratio between coil 1 and coil 2 for each single phase, was performed. To analyze the current limiting characteristics of this integrated three-phase flux-lock type SFCL, the short circuit experiments was carried out the various three-phase faults such as the single line-to-ground fault, the double line-to-ground fault, the triple line-to-ground fault. From the experimental results, the fault current limiting characteristic was improved according to increase of fault current level.

  • PDF