• Title/Summary/Keyword: current driving

Search Result 1,383, Processing Time 0.034 seconds

Current Equation Loop Design of Muti-channel Direct Drive Valve Actuation (다중채널 직접구동 엑츄에이터의 구동전류 동일화 루프 설계)

  • Nam, Yoonsu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.162-169
    • /
    • 2000
  • A Direct Drive Valve(DDV) hydraulic actuation system which is commonly used as an aircraft's control surface driving actuator has multi-loop control structure to ensure its safety operation. However, because of not perfect matching of one self channel characteristics with the others, the servo valve driving current of each channel can be widely different. Therefore, the long-time use of DDV actuator without any correction of these channel current offsets will cause the problem of performance or life expectancy degradation due to unwanted heats in the linear motor. A current equalization loop structure which can minimizes current offsets between channels is introduced and designed. The performance of the current equalization loop is investigated and verified through the analytic and experimental ways.

  • PDF

Analysis on Eddy Current Losses of High Speed Permanent Magnet Synchronous Motor for Turbo Compressor according to Voltage Source Driving (전압 구동 방법에 따른 터보 압축기용 초고속 영구자석 동기 전동기의 회전자 손실 해석)

  • Jang, Seok-Myeong;Kim, Hyun-Kyu;Ko, Kyoung-Jin;Lee, Sung-Ho;Hong, Young-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.712_713
    • /
    • 2009
  • This paper deals with the analysis on eddy current looses of high speed permanent magnet synchronous motor (PMSM) for turbo compressor according to voltage source driving. This paper presents analytical procedures for calculation of the eddy current losses using Poynting theorem. On the basis of the magnetic vector potential and a two-dimensional (2-D) cylindrical coordinate system, this paper derived analytical solutions of the eddy current looses using phase current analysis. The eddy current losses of each harmonic obtained by fast Fourier transform (FFT) analysis of phase current are with results obtained from finite-element method (FEM).

  • PDF

Effect of Electric Current on Friction Characteristics of Machine Driving Elements (기계구동 부재의 마찰특성에 미치는 전류의 영향)

  • Jun, Sung-Jae;Cho, Yon-Sang;Park, Heung-Sik
    • Tribology and Lubricants
    • /
    • v.18 no.5
    • /
    • pp.339-344
    • /
    • 2002
  • Whenever moving surfaces of machine driving elements interact in air and lubricating oil, oxidization film on the surfaces are generated. It is effect to prevent friction and wear on contact area. Since the electronic current progress the oxidization of metal, if the electronic flow be regulated, the thickness of oxidization film can be regulated and friction characteristics can be improved. But the electronic current can deteriorate friction characteristics, so various characteristics must be investigated on transforming of electronic current. Therefor, using the Norton equation in this study, short current were transformed between frictional materials using ball on disk type tester. It was studied on effect of electronic current for friction characteristics.

An Fuzzy-based Risk Reasoning Driving Strategy on VANET

  • Lee, Byung-Kwan;Jeong, Yi-Na;Jeong, Eun-Hee
    • Journal of Internet Computing and Services
    • /
    • v.16 no.6
    • /
    • pp.57-67
    • /
    • 2015
  • This paper proposes an Fuzzy-based Risk Reasoning Driving Strategy on VANET. Its first reasoning phase consists of a WC_risk reasoning that reasons the risk by using limited road factors such as current weather, density, accident, and construction, a DR_risk reasoning that reasons the risk by combining the driving resistance with the weight value suitable for the environment of highways and national roads, a DS_risk reasoning that judges the collision risk by using the travel direction, speed. and distance of vehicles and pedestrians, and a Total_risk reasoning that computes a final risk by using the three above-mentioned reasoning. Its second speed reduction proposal phase decides the reduction ratio according to the result of Total_risk and the reduction ratio by comparing the regulation speed of road to current vehicle's speed. Its third risk notification phase works in case current driving speed exceeds regulation speed or in case the Total_risk is higher than AV(Average Value). The Risk Notification Phase informs rear vehicles or pedestrians around of a risk according to drivers's response. If drivers use a brake according to the proposed speed reduction, the precedent vehicles transfers Risk Notification Messages to rear vehicles. If they don't use a brake, a current driving vehicle transfers a Risk Message to pedestrians. Therefore, this paper not only prevents collision accident beforehand by reasoning the risk happening to pedestrians and vehicles but also decreases the loss of various resources by reducing traffic jam.

The AC Chopper LED Driving System Using The Y Type Balancing Transformer (Y형 밸런싱 트랜스포머를 적용한 AC초퍼 LED 구동 시스템)

  • Kim, Jin-Gu;Yoo, Jin-Wan;Kim, Yong-Ha;Park, Chong-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.22-29
    • /
    • 2015
  • The AC-LED driving system which is connected directly to alternative current source is suitable for commercialization because of it's simple structure and low cost. However, it requires additional circuits compensating for current differences between the parallel connected LED strings. In this paper, we proposed the circuit compensating for current error of the three LED strings using the Y type balancing transformer. The proposed Half-bridge AC Chopper LED driving system used the ferrite material's balancing transformer. at the same time, it is able to dimming control. The proposed system is applied to 80W AC-LED module consist of three parallel strings. Experiment results present that Power factor and THD measured with power analyzer are 0.958 and 26.473% respectively satisfied with IEC61000-3-2 harmonics standard.

Noise Source Identification of the Design Elements of the Driving Gear for the Urban Railway (도시철도용 구동기어의 설계 요소에 대한 소음 기여도 분석)

  • Kim, Kinam;Lee, Hyuncheol;Sun, Chanwoong;Lee, Sungwook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.7
    • /
    • pp.470-480
    • /
    • 2015
  • As the railway noise guideline of the Ministry of Environment after 2017 is strictly enforced, the noise level at stationary condition of urban railway is demanding the reduction about 2 dB(A). And the noise level at running condition is reduced by 6 dB(A) at 80 km/h. Therefore, the devices that causes noise shall arrange for the improvement plan of noise reduction for each device. In this paper, we carried out a technical review of the driving gear used to drive the vehicle from a variety of noise-induced equipment of a urban railway. Analyze the causes of the current noise levels and noise cause about the driving gear used in current urban railway and this study analyzes the noise level and noise cause the drive gear being used in the current urban railway. Finally, in this paper proposes a scheme for reducing the noise that can be designed to reduce the noise with considering the noise cause analysis.

RESISTANCE ESTIMATION OF A PWM-DRIVEN SOLENOID

  • Jung, H.G.;Hwang, J.Y.;Yoon, P.J.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.249-258
    • /
    • 2007
  • This paper proposes a method that can be used for the resistance estimation of a PWM (Pulse Width Modulation)-driven solenoid. By using estimated solenoid resistance, the PWM duty ratio was compensated to be proportional to the solenoid current. The proposed method was developed for use with EHB (Electro-Hydraulic Braking) systems, which are essential features of the regenerative braking system of many electric vehicles. Because the HU (Hydraulic Unit) of most EHB systems performs not only ABS/TCS/ESP (Electronic Stability Program) functions but also service braking function, the possible duration of continuous solenoid driving is so long that the generated heat can drastically change the level of solenoid resistance. The current model of the PWM-driven solenoid is further developed in this paper; from this a new resistance equation is derived. This resistance equation is solved by using an iterative method known as the FPT (fixed point theorem). Furthermore, by taking the average of the resistance estimates, it was possible to successfully eliminate the effect of measurement noise factors. Simulation results showed that the proposed method contained a sufficient pass-band in the frequency response. Experimental results also showed that adaptive solenoid driving which incorporates resistance estimations is able to maintain a linear relationship between the PWM duty ratio and the solenoid current in spite of a wide variety of ambient temperatures and continuous driving.

Comparison of Operation and Driving Characteristics of Energy Recovery Circuit for an AC Plasma Disaplay Panel (AC Plasma Display Panel용 에너지 회수 회로의 동작과 구동 특성비교)

  • 최병조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.674-677
    • /
    • 2000
  • Operational principles and driving characteristics of two well-known energy recovery circuits for ac plasma display panels Weber and Sakai circuits are investigated Efficiency of two circuits is analyzed by comparing the in put current of the circuits with different operating conditions. Driving characteristics of the Weber circuit are studied when the magnitude and pulse width of the driving boltage very.

  • PDF

Design of Multi-Phase Shift Controller for Valveless PZT Pump (밸브리스 압전펌프 연동구동 제어기 설계)

  • 조정대;박경민;노종호;함영복;유진산
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1282-1285
    • /
    • 2004
  • The high voltage driving system with multi-phase shifter including piezoelectric actuators comprised a driving power unit for outputting the driving power by converting input alternate current into direct current, a frequency shifting unit for supplying the direct current power and shifting or generating a frequency, a high-voltage amplification unit for amplifying the input signal outputted from the driving power unit and the frequency shifting unit into a high-voltage signal, and a phase shifting unit for shifting the phase difference of the amplified signal applied to the high-voltage amplification unit and driving plural piezoelectric actuators sequentially. The results that the operating voltage was stable, the voltage loss ratio was low and the response velocity was fast could be obtained. An experiment on performance of the high voltage driving system with multi-phase shifter designed and manufactured as above described was conducted by using a piezoelectric pump having 3 sheets of round unimorph piezoelectric actuators laminated respectively in a rectangular case. It sucks any fluid by causing the first piezoelectric actuator to shift from the inlet porter side, the phase delay of 60$^{\circ}$ causes the second piezoelectric actuator to begin to shift, and the phase delay of 120$^{\circ}$ causes the third piezoelectric actuator to begin to shift. As a result of measuring each change in the outlet flow rate of the piezoelectric pump, it was shown that the frequency-flow rate characteristic, the voltage-flow characteristic, and the load pressure-flow rate characteristic were improved.

  • PDF

Design of Dual-channel Interleaved Phase-shift Full-bridge Converter

  • Che, Yanbo;Wang, Dianmeng;Liu, Xiaokun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1529-1536
    • /
    • 2017
  • A digital dual-channel interleaved phase-shift full-bridge converter is investigated in this paper, and its topology and principle are analyzed. To realize current sharing and stabilize the output voltage, a controller with current sharing loop and closed voltage loop is employed. In addition, current sharing will increase the output current fluctuation and a new digital interleaved driving technology is proposed to reduce the output current ripple. To verify the analysis, simulation and experiments are carried out, which shows the effectiveness of the proposed control strategies.